01 COA & batch testing

What the COA for L-ornithine actually contains

Technical document 01 · Reviewed 2026-11-19 · L-Ornithine

On this page
  1. The certificate as a table of evidence
  2. Dried basis, entity and the form
  3. Release limit and measured result
  4. What can differ from lot to lot
  5. When an outside test is worth it
  6. Comparing two suppliers

An L-ornithine lot certificate has to do more than quote a percentage. It should name the form, report the HPLC assay against a stated basis, give the specific rotation with its conditions, and show the pH of a 1% solution; those four lines decide whether the powder is the free base the catalog describes. The batch result then sits beside each release limit, not in place of it.

In one line

The assay says how much ornithine the powder carries; the rotation and the pH say it is the L free base, and the form has to be named before either figure means anything.

The certificate as a table of evidence

Each parameter needs a test, a method and a release limit. A row that reads only “conforms” gives the reader a conclusion without the measurement behind it. The table below is the catalog panel; the batch certificate adds the measured result for the lot.

Release panel · L-ornithine free base
Test itemProcedureAcceptance limit
AppearanceVisualWhite crystalline powder
IdentificationIR plus HPLC retentionMatches the reference
Assay (basis stated)HPLC98.5–101.5%
Specific rotationPolarimetry, dried basis+22.0° to +24.0°
Loss on dryingGravimetric≤0.5%
pH (1% solution)Potentiometry9.0–11.0
Heavy metalsICP-MS, each elementPb ≤3, As ≤2, Cd ≤1, Hg ≤0.1 mg/kg
MicrobiologyPlate count, absence testsTotal plate count ≤1,000 cfu/g; yeast/mould ≤100 cfu/g; E. coli, Salmonella: absence confirmed
Particle sizeSieve analysis≥95% through 40 mesh

Identification and rotation answer the identity question; the assay answers quantity; loss on drying supplies the denominator; pH distinguishes the base from the salt. The remaining lines describe what else is present.

Dried basis, entity and the form

An assay is only a number once its basis is fixed. If a lot reads 98.6% as received and loses 0.4% on drying, the dried-basis figure is 99.0%. Both percentages can be correct, but they describe different powders. The basis should be printed in the assay row, not buried in a note.

The second half of the basis is the entity. On the free base, the assay is the ornithine content. A hydrochloride lot calculated as ornithine would land near 78%, because the salt is only about 78.4% ornithine by mass. If the laboratory calculates the salt as the salt, the same material can read near 100%. The certificate has to say which convention it used.

The rotation and the pH close the loop. Specific rotation depends on solvent, concentration and temperature, so a figure without those conditions cannot be reproduced. The 1% pH window of 9.0–11.0 is consistent with the free base; a hydrochloride solution sits well below it. A lot that passes the assay but fails the pH is not the catalog form, even if the percentage looks right.

Release limit and measured result

The limit is the acceptance boundary; the result is the measurement. Both belong on the page, with the method named. A result column filled with the specification range is not evidence that the lot was tested.

What the result column should show
TestAcceptance boundaryWhat the result should be
Assay98.5–101.5%, basis statedA measured figure, with the entity and basis stated
Specific rotation+22.0° to +24.0° dried basisThe measured figure and the conditions
Loss on drying≤0.5%A measured percentage
pH (1% solution)9.0–11.0The measured pH at the stated strength
Heavy metalsPer elementA separate mg/kg figure for each metal
MicrobiologyCounts plus absenceThe plate count and an absence result for the lot

A total heavy-metal figure hides which element is present. A microbiology statement needs a count and an absence result. An identity statement needs the spectrum or the retention, not a tick.

What can differ from lot to lot

Fermentation and crystallisation shift colour and residual water; drying shifts the loss on drying; milling and sieving shift the particle-size result. Those movements are normal and do not by themselves mean an identity problem, as long as the rotation and the pH remain in their windows.

Rotation behaves differently from the other lines. It is controlled by the enantiomeric composition, so a normal lot repeats its value within a narrow band; an outlier points to a D-enriched or racemic source rather than to process drift. A low assay with a normal rotation points instead to moisture, a dilution or a calculation error.

pH is the early indicator of exposure. An alkaline powder that has been open takes water and carbon dioxide, and the 1% solution falls within the 9.0–11.0 window before the assay moves much. A lot near the floor of the window deserves a look at the pack record.

When an outside test is worth it

Send a sample out for a new supplier, a first import into a regulated market, a disputed form or a rotation sitting at the edge of the window. The useful panel is targeted: HPLC for identity and assay, polarimetry for rotation, loss on drying, pH and ICP-MS for the metals, plus microbiology. Add chloride when the hydrochloride is possible, and chiral HPLC when the rotation suggests a mixed enantiomer.

Ask each laboratory for its detection limit. A “not detected” result without a limit describes the method's sensitivity, not the sample. For a chiral check, ask for the enantiomeric ratio so the number can be compared with the certificate.

Keep the chain of custody intact. The tested portion should come from the retained sample, and the report should identify the lot. If a result is contested, hand the referee the retention sample plus the certificate and specification, then request the discriminating tests instead of repeating the same assay.

Comparing two suppliers

Line up seven items: form and CAS; assay with its entity and basis; identity method; rotation with conditions; loss on drying; pH at a stated concentration; and mesh with the lot code. Two offers that agree on assay but disagree on entity or basis are not selling the same powder.

The second layer is traceability. The certificate should name the producer, the process and the drying and milling steps, and the lot code should tie the pouch, the drum and the retention sample together. The catalog sheet is on the product hub; the identity tests are on the identity page; the free base and the salt are compared on the grades page; the HPLC method has its own method note; the quality page sets out the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation