01 COA & batch testing

What the COA for L-leucine actually contains

Technical document 01 · Reviewed 2026-11-19 · L-Leucine

On this page
  1. The certificate as a line-by-line report
  2. Titration, HPLC and the dried basis
  3. Release limit, batch result and the lines that get skipped
  4. What moves from lot to lot
  5. When an outside laboratory is worth ordering
  6. What to put side by side

A leucine certificate is a chain of evidence, not a single number. It should identify the material, give the assay and the basis it was calculated on, state the rotation and its conditions, and show the physical and contaminant tests that decide whether the lot can be used. The limits below are the catalog specification; the lot COA is the document that ties one drum to those limits.

In one line

The assay tells you how much leucine is in the drum; the basis and the rotation tell you what that number means.

The certificate as a line-by-line report

The first test of a certificate is whether a stranger could repeat the release decision from it. Parameter, method, limit and result should line up, and the method should be specific enough to mean something. A sheet that prints “conforms” for identification without naming the test has kept the conclusion and discarded the evidence.

Identity, assay and moisture · L-leucine
ParameterMethodRelease limit
AppearanceVisualWhite crystalline powder
IdentificationIR and ninhydrin reactionConforms to reference
Assay (dried basis)Titration98.5–101.5%
Specific rotation (dried basis)Polarimetry+14.9° to +17.3°
Loss on dryingGravimetric≤0.5%
Residue on ignitionGravimetric≤0.1%
pH (5% solution)Potentiometry5.5–6.5
Physical, contaminant and microbiological limits
ParameterMethodRelease limit
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Titration, HPLC and the dried basis

Leucine has one amino group and one carboxyl group, so an acid–base titration sees a single basic centre per molecule. That is why the method is precise, and also why it is not selective. Isoleucine and norleucine are isomers with the same formula, valine is one methylene shorter, and each molecule carries one amino group. The titration responds to all of them and cannot tell them apart. A blend can therefore land inside 98.5–101.5% while the drum contains less leucine than the label implies.

An HPLC method adds the separation the titration lacks. Leucine's UV absorbance at 210 nm is weak, so a reliable method derivatises the amine or runs an amino-acid analyser with ninhydrin. The chromatogram should show leucine resolved from isoleucine and valine, not just a single peak at the expected time.

Dried basis corrects the assay for water. At 99.0% as-is and 0.4% loss on drying, the dried figure is 99.4%; the correction is small in the middle of the range and decisive at the edges. A lot at 100.9% with 0.5% water becomes 101.4%, near the ceiling; the same result at 0.2% water is 101.1%. The as-is and dried values should both be visible, because water is mass that is not leucine.

A result above 100% is a method recovery, not extra purity. Titration standards and drying corrections carry a small bias; 100.8% means the method recovered slightly more than its standard, not that the drum contains more than pure leucine.

Release limit, batch result and the lines that get skipped

The limit column is the acceptance criterion; the result column is the measurement. A sheet that repeats the range under “result” has not reported the lot. The method column is what makes the other two auditable.

Three lines need context. Rotation: the reading changes with solvent, concentration, cell length and temperature, so a range without conditions cannot be reproduced. pH: 5.5–6.5 at 5% is near leucine's isoelectric point; a shift downward points to residual acid, upward to base or ammonia, and neither is a purity verdict by itself. Residue: the ≤0.1% cap limits inorganic salts; a low assay with a high residue is a different problem from a low assay with a low residue.

A pass is a conclusion, and the sheet should carry the evidence for it rather than the conclusion alone.

What moves from lot to lot

Fermentation titre, crystallisation and drying move the assay. Water follows the dryer and the humidity of the packing room. Mesh follows the mill and the sieve. pH follows neutralisation and washing. Rotation should stay in a narrow band for a genuine L lot; a drift toward zero is a chiral problem, not ordinary batch variation.

Colour is the least measurable line on the sheet and often the earliest signal. A cream tint can come from the mother liquor, a hot dryer or trace iron while the assay still passes. Look at the batch record and the retained sample before rejecting a lot on shade.

One result at the edge is a question. A sequence of three lots moving the same way is a supplier conversation.

When an outside laboratory is worth ordering

An outside laboratory is worth ordering at four points: a new manufacturer, a first shipment into a regulated market, a certificate without a rotation, or a result that cannot be reconciled. The panel should be targeted: polarimetry with conditions, chiral HPLC for D-leucine, IR against a reference, an amino-acid profile that resolves leucine from isoleucine and valine, ICP-MS for the metals, and the micro panel.

Ask for the detection limit of the chiral method. A “not detected” entry with no limit says more about the method than about the drum. The same applies to the amino-acid profile: the report should name the column and the detection mode.

Keep the chain of custody. The referee should test the retained sample, and the lot code should follow the sample from the drum to the report.

What to put side by side

Supplier comparison lines for L-leucine
LineWhy it separates offers
Form and CASFree L-leucine 61-90-5, DL-leucine 328-39-2 and a blend are different materials
Assay and basisA dried-basis titration and an as-is HPLC result are not interchangeable
RotationThe value plus solvent, concentration, temperature and basis
Water≤0.5%; a 0.2% lot and a 0.5% lot behave differently in a humid room
pH and residueProcess indicators; a low assay with high ash is a salt problem
Mesh40 mesh, 80 mesh and granulated lots have different flow
Metals and microLimits and methods should match the destination market
TraceabilityOne lot code on the certificate, the pack and the retained sample

Two offers can agree on 99% and disagree on rotation, water and mesh; that is not the same powder. The lot code is the second half of the comparison: manufacturer, route, certificate, drum and retained sample should point to one another.

The catalog specification sits on the L-leucine product page. The form question is covered on the grade page, the tests that distinguish the L form from a blend on the identity page, and the release workflow on the quality page. The HPLC method is set out in the HPLC note.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation