What the L-carnitine tartrate COA actually contains
The certificate for an L-carnitine L-tartrate lot reports appearance, identification by HPLC and infrared, the salt assay, the L-carnitine content, loss on drying, the heavy-metal panel, microbiology and particle size. The two percentage figures are not interchangeable: the assay describes the tartrate salt, while the carnitine content describes the fraction that a label conversion uses. A certificate is only comparable when each line states the method, the release limit and the measured result, together with the basis of the percentage.
The tartrate certificate carries two numbers that are easy to confuse: the salt assay and the carnitine content, and the second one is the figure a label conversion needs.
The certificate as a test report
A certificate can be audited line by line when each row names what was measured, how it was measured and the limit the lot was released against. A row that reads only “conforms” records a conclusion, not evidence. The table below is the catalog specification; the batch certificate is the document that confirms one lot against it.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | HPLC retention and infrared spectrum | Conforms to the reference |
| Assay (tartrate) | HPLC | 98.0–102.0% |
| L-Carnitine content | HPLC or titration | 68.0–72.0% |
| Loss on drying | Gravimetric | ≤1.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
Read the sheet in two blocks. The upper rows describe the material and its two percentages; the lower rows describe the powder and its contaminants. A certificate that reports the salt assay but omits the carnitine content has not told the buyer how much carnitine the drum carries.
Two percentages and the 2:1 ratio
L-carnitine tartrate is a 2:1 salt: two carnitine units of 161.20 g/mol and one L-tartaric acid unit of 150.09 g/mol give 472.49 g/mol. Carnitine is 322.40 ÷ 472.49 = 68.2% of that mass, and tartaric acid is the remaining 31.8%. The catalog sets the salt assay at 98.0–102.0% by HPLC and the carnitine content at 68.0–72.0%. The two ranges describe the same salt from different directions, and a certificate that reports one without the other leaves the buyer to guess.
The basis is the second question. The salt assay should say whether it is calculated on the powder as received or on the dried basis; with loss on drying at ≤1.0%, the difference is up to one percentage point. The carnitine figure should carry the same statement. When the carnitine result sits at the top of the catalog range beside a salt assay near 100%, ask which method produced it and whether the calculation used the stoichiometric factor, because the two figures should describe the same 2:1 salt.
Release limit, result and the line between them
A certificate has two jobs on every line: it states the acceptance boundary and then reports what the laboratory found. Keep those in separate columns and put the method next to the number. When the result column simply repeats the limit, the reader learns the gate but not the lot.
| Parameter | Release limit | Result column |
|---|---|---|
| Salt assay | 98.0–102.0% by HPLC | A measured percentage, with the basis |
| L-Carnitine | 68.0–72.0% | A measured percentage, with the method |
| Loss on drying | ≤1.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the sieve |
One-sided limits and two-sided limits behave differently. Water, metals and microbiology are one-sided: any result below the limit passes, and the number still matters because it shows margin. The assay and the carnitine content are two-sided windows, so a result near either edge is a conversation about method and sampling, not a pass mark.
What moves from lot to lot
Water is the first variable. The drying end-point and the packing-room humidity move the loss on drying, and that moves the as-is assay with it. Particle size is the second: the standard powder is ≥95% through 80 mesh, and a mill or sieve change can shift the fines without changing the chemistry. Colour is the third: white to off-white covers a wide window, and a cream tint can come from the dryer or from the tartaric acid lot.
Two lines move less often but say more. The carnitine content should track the salt assay within the stoichiometric ratio; a gap between them points to a blend, a different salt or a calculation error. The infrared identity should be stable across lots; if the spectrum changes, the counter-ion or the solid form has changed, and the certificate needs a closer look rather than a new pass statement.
When an outside laboratory is worth it
Order an independent test for a new source, a first shipment into a regulated market, a certificate that reports one percentage without the other, or a disputed lot. The useful panel is targeted: HPLC for the salt assay, a second HPLC or titration for carnitine, infrared for identity, loss on drying, ICP-MS for the metals and a plate count for microbiology. Add chiral HPLC for D-carnitine and a tartrate-specific test if the form is in question.
Ask the laboratory to report its detection limit for each screen. “Not detected” without a limit describes the method, not the sample. When a result is contested, the sample tested should be the retained sample from the lot, and the lot code on the certificate, the pack and the referee report should match.
What to compare between suppliers
Put six lines side by side: the form and CAS number, the salt assay with its method and basis, the carnitine content with its method, the loss on drying, the contaminant and micro panel, and the particle size. Two quotations that agree on the salt assay but differ on carnitine are not describing the same powder; two that agree on both but differ on water will run differently on a capsule line.
The second layer is traceability. The certificate should name the manufacturing site and the pack date, and the lot code should be the same string on the pouch, the drum and the retained sample. The catalog specification sits on the L-carnitine tartrate product page; the counter-ion evidence is on the identity page; the grade and fill arithmetic is on the grades page; the test methods are described in the methods index; the release workflow is on the quality page; and the base form is on the L-carnitine product page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation