01 COA & batch testing

What the COA for vitamin D3 oil actually contains

Technical document 01 · Reviewed 2026-11-20 · Vitamin D3 Oil

On this page
  1. The certificate as a test report
  2. IU per gram, not a percentage
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a vitamin D3 oil lot reports appearance, identification by HPLC and UV, potency in IU per gram, peroxide value, the heavy-metal panel and microbiology. The method, the limit and the measured result should each have their own column. The figures below are the catalog specification for the 1.0 MIU/g oil; the batch COA confirms a particular bottle.

In one line

Potency on a D3 oil certificate is an as-is figure in IU per gram, and it means little without the peroxide value and the HPLC identity beside it.

The certificate as a test report

An audit reads the certificate row by row. A line is complete when it says what was measured, how, and against which limit the lot passed. “Conforms” alone is a conclusion with the working removed; the method and the measured figure are the working.

The identity row and the potency row answer different questions. HPLC retention and the UV spectrum say the peak is cholecalciferol; the IU figure says how much of it sits in the oil. A certificate that prints only the IU figure has measured the second question and skipped the first.

Identity, potency and contaminants · vitamin D3 oil
ParameterMethodRelease limit
AppearanceVisualClear, pale yellow oil
IdentificationHPLC retention and UV spectrumConforms to the reference
PotencyHPLC with UV detection1.0–1.1 MIU/g
Peroxide valueIodometric titration≤10.0 meq O₂/kg
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
CarrierSpecification and batch recordNamed on the specification and the certificate

IU per gram, not a percentage

The potency of an oil is reported in IU per gram, not as a percentage. One microgram of cholecalciferol is 40 IU, so 1.0 MIU/g is 1,000,000 IU/g, 25,000 µg/g, 25 mg/g and about 2.5% by mass. The top of the range, 1.1 MIU/g, is 27,500 µg/g, or 2.75%.

The oil is measured as received. There is no anhydrous basis and no loss-on-drying line, unlike the spray-dried powder where moisture enters the assay calculation. The number on an oil certificate is IU per gram of oil as weighed, and the peroxide value sits beside it as a separate quality result.

Confirm how the conversion was made. An HPLC result is usually produced as micrograms per gram against a cholecalciferol standard and multiplied by 40; the certificate should state the detection wavelength and the standard. An IU figure with no conversion note is harder to audit, and a figure copied from a supplier’s marketing sheet is not a result.

Release limit versus batch result

The limit tells the reader where acceptance stops, while the result tells them what this lot actually contained. Keep them apart: a column that repeats the range has restated the limit rather than reported a measurement. The method belongs beside both.

What the result column should contain
ParameterRelease limitResult column
Potency1.0–1.1 MIU/gA measured IU/g figure with the method and the standard
Peroxide value≤10.0 meq O₂/kgA measured figure in meq O₂/kg
IdentificationConforms to the referenceThe retention time and the spectrum statement
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
AppearanceClear, pale yellow oilA description of the lot as received

What moves between batches

Three things move between oil lots: the potency of the concentrate, the peroxide value of the carrier, and the colour of the oil. Potency moves with weighing, dilution and the standard. Peroxide value moves with the age and quality of the carrier, the antioxidant package and the headspace in the bottle. Colour moves with the carrier lot.

The catalog range is 1.0–1.1 MIU/g. A lot at 1.02 MIU/g and a lot at 1.09 MIU/g are both inside it, and a formula weighed at 1.0 MIU/g receives up to 10% more IU from the second. That is a reason to record the IU/g used in the weigh-up, not a reason to reject the lot.

A drift across several lots carries more weight than any single number close to its limit: peroxide climbing, potency drifting down, or colour darkening. The certificate’s lot code should be traceable to the bottle and to the sample kept in the retain room.

When to order an outside test

Independent testing earns its cost at four moments: a new source, a first export to a regulated market, a potency disagreement, or a peroxide result near the ceiling. The useful panel is HPLC with UV spectrum for identity and potency, peroxide value, ICP-MS for the metal panel, microbiology, and a fatty-acid profile by GC if the carrier oil is in question.

Add a vitamin D2 screen when the label names D3 and the lot looks unusual. D2 has a different retention time and a different spectrum, and the assay alone may not separate the two. Ask the laboratory to report its detection limit and to tie the report to the lot code, not only to the product name.

Chain of custody matters. The material that goes to the laboratory should be the material in the retain sample, and the report should carry the lot code. In a dispute, hand the referee the retain sample, the supplier’s certificate and the agreed specification, and ask for the discriminating tests rather than a second run of the same potency method.

What to compare between suppliers

Compare six fields: form and CAS number; IU/g and the method; carrier oil; antioxidant package; peroxide value; pack and lot code. Two offers that agree on IU/g but differ on the carrier or the antioxidant are not the same oil, even when the certificate headline matches.

Traceability forms the second layer. The certificate should identify the manufacturer, the carrier batch and the pack that was filled. The product hub lists the catalog values. The spray-dried D3 page shows how the same molecule is specified on a solid carrier; the analytical methods index explains what each test proves; the quality page describes the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation