01 COA & batch testing

What the COA for tocopheryl succinate actually contains

Technical document 01 · Reviewed 2026-11-20 · Tocopheryl Succinate

On this page
  1. The certificate as a test report
  2. What the 95% measures
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a tocopheryl succinate lot reports appearance, identification by HPLC and infrared, assay at ≥95.0% by HPLC, melting point 73–76 °C, loss on drying ≤1.0%, particle size, the heavy-metal panel and microbiology. Those figures are the catalog specification; the batch COA is the document that releases a particular pouch or drum. The ester line has to name d-alpha-tocopheryl succinate, because a certificate that says only “vitamin E” does not say which ester was measured.

In one line

A 95% assay is a statement about d-alpha-tocopheryl succinate, and the melting point and loss on drying are what stop that number from being read as any other vitamin E form.

The certificate as a test report

A useful certificate is auditable row by row: method, release limit and a separate column for the measured result. Identification is the row that decides the ester; the assay says only how much of the named ester is present.

Identity, assay, solid form and contaminants · tocopheryl succinate
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationHPLC retention and infrared spectrumConforms to the d-alpha-tocopheryl succinate reference
AssayHPLC with UV detection≥95.0%
Melting pointCapillary method73–76 °C
Loss on dryingGravimetric≤1.0%
Heavy metals (Pb, As, Cd, Hg)ICP-MS, multi-elementPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence screenAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis, 80 mesh≥95% through 80 mesh

The melting point is a form check rather than a purity assay. A crystalline succinate melts sharply inside 73–76 °C; a depressed or wide range points to moisture, a mixed crystal or a different ester. The infrared spectrum adds the functional-group evidence: the succinate shows an ester carbonyl and an acid group that the acetate does not carry.

What the 95% measures

The assay is the mass fraction of d-alpha-tocopheryl succinate, reported on the as-sold basis unless the certificate states another basis. Because loss on drying is allowed up to 1.0%, a result calculated on the dried material is at most about one percentage point above the same powder as weighed. That correction belongs in the assay row, not a footnote.

Nor is 95% the same as 95% tocopherol. The succinate carries a succinic acid group, so the tocopherol fraction is 430.71 ÷ 530.78 = 81.2% of the ester by mass. A 95.0% powder therefore contains about 77.1% tocopherol. In potency terms, 1 mg of d-alpha-tocopheryl succinate is 1.21 IU, so 1 g of the 95.0% powder is 1,149.5 IU. The label conversion is 0.81 mg alpha-tocopherol equivalent per mg of succinate.

The assay is run against a d-alpha-tocopheryl succinate reference. It does not measure the acetate, and on an achiral column it does not prove the natural d isomer either. If the natural form is part of the label, ask for chiral separation or specific rotation after hydrolysis.

Release limit versus batch result

The release limit is the acceptance boundary. The result is what the laboratory measured on that lot. Both should appear, in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not a measurement.

What the result column should contain
ParameterRelease limitResult column
Assay≥95.0% by HPLCA measured percentage, with the reference standard and the basis
Melting point73–76 °CThe observed range, not only “conforms”
Loss on drying≤1.0%A measured percentage
Heavy metalsPer elementA measured mg/kg figure per element
MicrobiologyCounts and absenceA plate count and an absence statement

A low assay with a normal melting range points to dilution or a different ester; a normal assay with a high loss on drying points to moisture. A result that sits exactly on a limit leaves no room for the next storage step and deserves a note in the batch record. Particle size is a finishing line: a granulated variant has its own sieve result and should not be released against the 80 mesh line.

What moves between batches

Crystallisation and drying move the melting range, loss on drying and particle size. The assay normally sits above the 95.0% floor, but a lot near that floor and a lot several points above it are both within the specification and behave slightly differently at the balance.

Colour is a weak but useful signal. White to off-white covers a wide window, and a cream or tan tint can indicate heat exposure or oxidation while the assay still passes. A shift in the infrared spectrum or a new peak in the chromatogram is stronger evidence than colour.

The lot code on the certificate should match the pouch, the drum and the retained sample. A granulated grade belongs on its own particle-size line, not on the 80 mesh line.

When to order an outside test

An independent test earns its place for a new source, a first shipment into a regulated market, a label claim that has to be defended or a disputed result. The useful panel is not a full repeat of the supplier's certificate. It is HPLC assay and infrared identity, melting point, loss on drying, ICP-MS for each metal, microbiology and a sieve check.

When the ester is in doubt, add a saponification step: the succinate releases succinic acid, the acetate releases acetic acid, and the free tocopherol releases neither. When the isomer is in doubt, add chiral HPLC or specific rotation after hydrolysis, and add a residual-solvent screen if the process uses one. Ask the laboratory to report its detection limit for each test; a “not detected” line without a limit describes the method, not the sample.

Chain of custody matters: the sample tested should be the sample retained. If a result is contested, give the referee the retained sample, the certificate and the agreed specification, and ask for the tests that separate the forms rather than a second run of the same assay.

What to compare between suppliers

Put six lines side by side: exact ester and CAS number; assay result, method and basis; melting point; loss on drying; particle size; and the contaminant and microbiological panels. Two quotations that both say 95% but describe different esters, melting ranges or sieves are not offering the same powder.

The second layer is traceability. The certificate should name the manufacturer, the specification version it was released against and the pack the lot went into. A correct certificate can still belong to a different drum, so the lot code has to run through the certificate, the pack and the retained sample.

The catalog ranges are on the tocopheryl succinate product page. The identity tests are set out on the identity page; the forms are compared on the grade page; the ester difference is taken further in the succinate versus acetate comparison. The methods library includes the HPLC note, and the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation