What the COA for inositol actually contains
The certificate for a myo-inositol lot reports appearance, identification by IR, melting point, assay by HPLC, loss on drying, residue on ignition, the heavy-metal panel, microbiology and particle size. Read it as a test report: parameter, method, limit and that lot's result. The ranges are the catalog specification; the batch COA confirms one drum. An assay without method and isomer does not identify the material.
An inositol assay is only meaningful when the certificate names the detection method, the assay basis and the isomer it measured.
The certificate as a test report
Each row should carry three things: what was measured, which method produced the number, and which limit the lot was released against. Without the method column, two suppliers' tables cannot be compared, because the same word can describe two different measurements.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White crystalline powder |
| Identification | IR spectroscopy | Spectrum conforms to reference |
| Melting point | Capillary method | 224–227 °C |
| Assay (myo-inositol) | HPLC | 99.0–101.0% |
| Loss on drying | Gravimetric | ≤0.5% |
| Residue on ignition | Gravimetric | ≤0.1% |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Parameter | Method | Release limit |
|---|---|---|
| Lead (Pb) | ICP-MS | ≤3 mg/kg |
| Arsenic (As) | ICP-MS | ≤2 mg/kg |
| Cadmium (Cd) | ICP-MS | ≤1 mg/kg |
| Mercury (Hg) | ICP-MS | ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Identification and melting point are identity checks, not purity figures. The heavy-metal panel is a release gate and a specification line, not a label claim. That separation stops a “passes” summary from standing in for the evidence.
What the assay measures, and on what basis
The assay is a quantitative HPLC result for myo-inositol against a reference standard. A range of 99.0–101.0% is normal for an assay that includes the uncertainty of the standard, the preparation and the integration. A result above 100% is not a super-pure lot; the method, standard and moisture basis explain it.
The basis matters. An as-is result includes the moisture that loss on drying measures; a dried-basis result excludes it. With a loss on drying limit of ≤0.5% the gap is small, but it is not zero, and the certificate should say which basis was used. Residue on ignition is inorganic material, and subtracting both moisture and residue from 100 does not yield a valid assay; that arithmetic mixes three measurements.
Myo-inositol has no useful ultraviolet chromophore, so the method usually relies on refractive index (RI), evaporative light scattering (ELSD), or electrochemical detection after anion exchange. RI is temperature-sensitive and gradient-limited; ELSD needs a volatile mobile phase. The method should name the column, mobile phase, detector and standard, not only the word HPLC.
Assay is not total sugar. A colorimetric total-sugar method measures a class of compounds and cannot distinguish myo-inositol from glucose, sorbitol, mannitol or another cyclitol. A certificate line reading “total sugar ≤1%” is an impurity limit, not an assay; a “99% total sugar” result could describe a drum that is mostly glucose. The number becomes an inositol assay only when the method separates and identifies the peak.
The isomer is the last part of the basis. Myo-inositol and D-chiro-inositol share the formula C₆H₁₂O₆ and the same molecular mass. One peak at the retention time of a myo standard does not prove the peak is myo unless the method has been shown to resolve the isomers, or a second technique confirms the structure.
Release limit versus batch result
The release limit is the acceptance boundary; the batch result is what the laboratory measured on that lot. They belong in separate columns, with the method beside them. A result column filled with the specification range is not a result; it is a copy of the gate. A certificate that reports only “conforms” for every line is a conclusion; the reader should still be able to reach it from the numbers.
Some parameters are pass/fail by nature. Identification by IR is a comparison with a reference spectrum, and “conforms” is legitimate if the certificate names the reference and the instrument. Melting point, assay, loss on drying, residue and each metal are numeric and need a result. Where a result is “not detected”, the reporting limit belongs on the page: a metal below the limit is not zero, and a screen without a stated limit says more about the laboratory than about the drum. Moisture and residue also change the fill weight: a lot at the top of the loss-on-drying limit carries less inositol per gram than a dry lot at the same as-is assay.
What moves between batches
Assay, loss on drying, residue and particle size move with crystallisation, drying, milling and sieving. A different drying end-point shifts moisture; a different mill shifts the particle-size distribution and the proportion of fines. These are process variables, not signs that the molecule changed, and the batch result shows where the lot landed inside the range.
Colour and flow are less quantitative and often more revealing. A tint can point to a drying step, a trace of metal or carry-over from the previous campaign; caking can point to moisture pickup. Neither is a rejection on its own, but a trend is worth a conversation before the next order.
The isomer deserves the same trend view. If the label claims myo-inositol only, a rising D-chiro figure in the assay changes what the drum is, even while the total assay stays inside the range.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a label claim the supplier's certificate does not prove, or a disputed result. The useful panel is not a full repeat. It is the set of tests that answers the open question: an isomer-resolving HPLC run, IR and melting point for identity, ICP-MS for the metal panel, and a sugar or sugar-alcohol screen where adulteration is a concern.
Ask the laboratory to state its detection and quantification limits, and whether it is accredited to ISO/IEC 17025 for that method. The sample tested should be the retained sample from the lot, not a fresh scoop without a lot code.
What to compare between suppliers
Put the certificates side by side on six lines. Two quotations that match on the assay headline but diverge on the other five are not describing the same powder.
| Line | Why it matters | What to ask |
|---|---|---|
| Isomer and assay method | Same formula, different molecule | Which isomer, and does the method resolve it? |
| Detector | RI, ELSD and electrochemical methods see different things | Column, mobile phase and detector |
| Assay basis | As-is and dried results are not interchangeable | Which basis, and what are LOD and residue? |
| Particle size | Flow, fill weight and dust | Sieve method and full distribution |
| Contaminants and microbiology | Release gates for the market | Results, limits and reporting limits |
| Lot traceability | The certificate must belong to the drum | Lot code on COA, drum and retained sample |
The specification sits on the inositol product page; grades are compared on the grade page, isomer tests on the identity page, and the detector choice in the HPLC method note.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation