03 Stability

Sodium hyaluronate is hygroscopic; moisture and heat decide the shelf life

Technical document 03 · Reviewed 2026-11-19 · Hyaluronic Acid

On this page
  1. A hygroscopic powder and a moisture ceiling
  2. Water is also the format problem
  3. What actually moves the result
  4. A stability protocol for the powder
  5. The formula and the pack
  6. Assigning the shelf life

Sodium hyaluronate is hygroscopic, and water plus heat shortens the chain. The dry powder is stable while it stays inside its ≤10.0% loss-on-drying limit; a solution is a different problem, where hydrolysis, pH and microbial growth act at once. The pack and the storage condition decide the shelf life, and the shelf life has to be supported by data on the commercial pack.

In one line

The dry powder is stable while it stays dry; moisture, heat and the pack decide how long the chain length and the assay survive.

A hygroscopic powder and a moisture ceiling

Sodium hyaluronate carries carboxylate groups and a sodium counter-ion along a hydrophilic chain, and it picks up water from the air. The water sits on the surface and between particles, and it changes the powder before it changes the assay: first the powder loses its flow, then it forms lumps that do not disperse in a blend, and finally the loss-on-drying result reaches the 10.0% ceiling. A lot released near the ceiling has little margin left in a humid filling room.

The 10.0% limit is a ceiling, not a target. Water is not hyaluronate, so a wet lot carries less dry matter per kilogram and its ≥91.0% assay is being carried by a larger mass. The powder may still pass the assay on the dried basis while the as-is material is out of specification on moisture. That is why the moisture result belongs beside the assay on the certificate, not in a storage note at the end.

The foil pouch is the moisture barrier, not the fiber drum. A torn liner, a poorly closed pouch or a drum opened in a humid room is the usual route by which a compliant lot leaves its specification in storage. The filling room humidity belongs in the handling instruction.

Water is also the format problem

In solution, water is not a bystander; it is a reactant. The glycosidic bonds in the chain can hydrolyse, and heat and extremes of pH accelerate the reaction. The visible result is a drop in viscosity and a fall in molecular weight, often before the assay moves far, because the assay counts mass while the chain is cut into shorter pieces. A solution that was thick at filling can be thin at the end of shelf life and still report a similar assay.

pH is the second control. The catalog window is pH 6.0–7.5 in 1% solution, and a beverage or gel that drifts outside that window during processing is a different stability subject from the dry powder. Heat is the third: a pasteurisation step, a hot fill or a warm warehouse all add to the same hydrolysis. If a liquid format is planned, the study has to run in that matrix, with the preservative system and the package included.

Microbial growth is the fourth. A solution with water activity high enough to support growth needs a preservative system or a process that achieves commercial sterility. A dry-powder micro result says nothing about a liquid format.

What actually moves the result

Factors that change sodium hyaluronate during storage and handling
FactorEffectControl
MoistureClumping, higher loss on drying, less dry matterFoil liner, desiccant, closed transfer
HeatHydrolysis, lower viscosity and molecular weightControlled warehouse; short heat exposure
pHFaster hydrolysis away from 6.0–7.5Buffer the formula; measure at 1%
Oxygen and radicalsChain scission, colour driftMinimise headspace; control metal ions
LightSurface colour change in an open packOpaque pack; keep it closed
Metal ionsComplexation and colour changeStainless contact surfaces; contaminant panel
ShearViscosity loss in a high-shear solutionControl mixing time and speed
MicrobesGrowth in an aqueous formatPreservative or sterility; validated pack

Moisture is the factor that unlocks the others. A dry powder held cool and closed is the easy case; a damp powder held warm is where colour, flow and molecular-weight problems appear together. Dry the pack first, then control temperature, then control oxygen and light.

A stability protocol for the powder

A useful study starts with at least three lots, including one at the low end of the assay range and one at the high end of the moisture range. Pack each lot in the commercial pack, not a laboratory bag: the 1 kg foil pouch and the 25 kg fiber drum with its liner are different moisture barriers and should be studied as they are sold.

Store the packs at 25 °C/60% RH for long-term data, 30 °C/65% RH for an intermediate condition and 40 °C/75% RH for accelerated data. Test at 0, 3, 6, 9, 12 and 24 months for the long-term condition, with at least 0, 3 and 6 months accelerated. Add a transport simulation if the material will sit in an unheated container or cross a cold chain.

Test appearance, sodium hyaluronate, glucuronic acid, molecular weight, loss on drying, pH, protein, the microbiological panel and pack integrity. Record net weight at each point. Set acceptance criteria before the first result, and read a result outside the criteria as a finding about the pack or the process, not as a reason to change the criteria.

The formula and the pack

In a capsule, the powder competes with the shell for water. A gelatin shell can donate or take up moisture, and a hygroscopic fill can make the capsule brittle or tacky over time; an HPMC shell behaves differently. The study should use the intended shell and fill weight, because a capsule study with a different shell does not answer the question. In a tablet, binders and lubricants add their own moisture and compaction behaviour.

In a powder stick, the foil laminate and the seal are the barrier; a poor seal fails faster than the same powder in a pouch. In a beverage, the bottle, the headspace oxygen and the preservative system join the list. The commercial pack is part of the specification: the 1 kg foil pouch suits a qualification or a small batch, and the 25 kg fiber drum with an inner liner suits production. If a desiccant or a nitrogen flush is required, it should be written into the order and the stability study, not assumed at the filling line.

Assigning the shelf life

The shelf life is the period supported by the stability data for the commercial pack, not a property of the molecule and not a number copied from another supplier’s certificate. A supplier can state a shelf life for the unopened pack; the buyer’s own data supports the finished product after filling. Both statements should name the storage condition and the pack.

Write the storage statement in plain terms: keep the pack closed, store away from heat and moisture, and use the material within the stated period after opening. A reopened 25 kg drum is no longer the pack that was studied. The COA page explains the moisture and assay lines the study follows, the ordering page covers the pack sizes, and the compliance page covers the storage statement on the label. The loss-on-drying entry defines the test, and the microbiology method note covers the panel.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation