01 COA & batch testing

Reading the COA for oat beta-glucan

Technical document 01 · Reviewed 2026-11-20 · Beta-Glucan Oat

On this page
  1. The certificate as a test report
  2. The enzyme sequence and the assay basis
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

An oat beta-glucan COA is a chain of three answers: how much beta-glucan the lot contains, on which basis that figure is expressed, and by which enzymatic procedure it was obtained. Around those answers sit the moisture, protein and ash results that make the mass balance readable, and the contaminant and microbiology panels that decide release. The specification in this catalog is the gate; the certificate is the record for one lot.

In one line

The beta-glucan percentage is only the first answer: the cereal enzyme procedure and the as-is or dry basis decide what the number means, and the moisture line decides whether the arithmetic closes.

The certificate as a test report

Begin with the material block. The certificate should name oat beta-glucan, the oat source or fraction and CAS 9012-72-0, because “beta-glucan” alone could be yeast, barley or a blend. The test rows come next, and each row should be readable without a phone call: what was measured, how, and against which limit.

Release tests for oat beta-glucan
TestProcedureLimit
AppearanceVisual examinationOff-white to light tan powder
IdentificationEnzymatic beta-glucan profile against the referenceConforms
Beta-glucanEnzymatic cereal method; procedure named≥70.0%
MoistureGravimetric drying≤7.0%
ProteinNitrogen determination, Kjeldahl or Dumas≤5.0%
AshResidue after ashing≤3.0%
Heavy metalsICP-MS, element by elementPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate counts and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Two rows deserve a second look. The identification row should say what the identification compared against; “conforms” without a reference is a word. The particle-size row should give the sieve and the percentage through it, because 80 mesh is a handling property that a buyer will notice in the hopper before the laboratory does.

The enzyme sequence and the assay basis

The cereal assay is a sequence, not a single reagent. Lichenase hydrolyses the mixed 1,3/1,4 chain at the 1,4 bond next to a 1,3 link, beta-glucosidase releases glucose from the fragments, and the glucose is measured and multiplied by 0.9 to express the anhydroglucose backbone. The certificate should name the procedure or kit: a cereal method and a yeast cell-wall method use different enzymes, and their percentages are not the same measurement.

Then the basis. A result on the powder as received includes the water; a result on the dried solids excludes it. At 6.2% moisture, a 68.0% as-is result becomes 72.5% on the dry basis (68.0 ÷ 0.938). The same powder can be reported as 68.0% or 72.5% depending on the convention, and the catalog's ≥70.0% only has a meaning once the convention is fixed.

The mass balance is the sanity check. With 70.0% beta-glucan, 5.0% protein, 5.0% moisture and 2.0% ash, roughly 18% is left for other carbohydrate, lipid and minor fractions. A gap much wider than that asks for an explanation; a gap much narrower asks whether the beta-glucan and moisture were run on the same sample.

Release limit versus batch result

The specification column is a decision rule. The result column is a measurement. When a certificate prints the same range in both, it has restated the rule and told the reader nothing about the lot. The result should carry a unit, the method beside it and, for the beta-glucan line, the basis.

What the result column should contain
TestLimitResult expected on the COA
Beta-glucan≥70.0% by the named enzymatic methodA measured percentage, with the method and the basis
Moisture≤7.0%A measured percentage
Protein≤5.0%A measured percentage and the nitrogen factor
Ash≤3.0%A measured percentage
Heavy metalsElement-specific limitsOne figure per element, in mg/kg
MicrobiologyCounts and absence statementsThe count and the absence finding for the lot

Contaminants and microbiology are the rows where a summary is least acceptable. A “metals pass” line does not show which element was near its limit, and a “micro pass” line does not show whether the aerobic count was 100 cfu/g or 900 cfu/g. The numbers are the evidence; the conclusion is the reader's.

What moves between batches

Three parts of the chain move the certificate. The grain moves the starting beta-glucan content, the fractionation and blending move it toward the catalog range, and the dryer and mill move moisture and particle size. A concentrate is designed to absorb the first two, so the lot-to-lot spread is usually narrower than the raw-material spread.

Protein and ash are the bran markers: a lot with more bran fraction carries more of both and usually a darker colour. Colour is a weak test but a useful prompt. A darker-than-usual powder should send the reader back to the protein, ash and moisture rows before anyone decides the lot is out of specification.

Look at direction over several lots. A beta-glucan figure that creeps toward 70.0%, a moisture figure that creeps toward 7.0% or a particle-size result that drifts below 95% is a process signal, not a single bad day. The lot code links the sheet, the pack and the reference sample; if those three codes disagree, stop there.

When to order an outside test

Outside testing is worth paying for when the supplier's sheet cannot answer the question: a new oat source, a first import, a method that is named but not described, or a result that both sides read differently. The second laboratory should not simply repeat the same panel. Ask for a second enzymatic result with its procedure, moisture, protein and ash, the metals by ICP-MS, microbiology and, where the market requires it, a gluten screen.

If the dispute is about the source rather than the amount, add a linkage test. The lichenase digest read by HPAEC-PAD, or a methylation analysis by GC-MS, shows the 1,3/1,4 pattern and the DP3/DP4 ratio that a percentage cannot. Neither belongs in routine release.

A detection limit belongs with every “not detected”. Without it, the reader knows the method's sensitivity, not the sample's content. Keep the tested sample sealed and identified by lot; a report without a sample trail is hard to defend.

What to compare between suppliers

Compare six rows: oat source and concentration; beta-glucan result, method and basis; moisture, protein and ash; particle size; gluten and allergen statement; pack and lot code. A pair of 70.0% certificates built on different methods is not a pair of equivalent offers.

Then compare the traceability behind the rows: who manufactured the lot, which oat fraction and process were used, and which drying and milling steps followed. The oat beta-glucan product page holds the catalog figures; the identity page covers the linkage evidence; the compliance page covers the market file; the yeast beta-glucan page documents the other source; the methods library and the quality page cover the procedures and release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation