01 COA & batch testing

What the COA for walnut protein peptides reports

Technical document 01 · Reviewed 2026-11-19 · Walnut Protein Peptides

On this page
  1. The certificate as a test report
  2. Kjeldahl protein, the factor and the as-is basis
  3. Release limit versus batch result
  4. What moves between lots
  5. When an outside test earns its place
  6. What to compare between suppliers

A walnut protein peptide certificate is read on two axes: how much nitrogen the powder carries, and how much of that protein sits in short chains. The first is a Kjeldahl result with a stated factor and basis; the second is an HPLC distribution with a stated molecular-weight window. The table below gives the catalog limits both results are released against; the batch COA shows a particular pack meeting them.

In one line

Protein is a nitrogen calculation and peptide is an HPLC fraction, so the certificate only means something when each figure carries its method, factor, basis and window.

The certificate as a test report

Each line should let a reviewer rebuild the release decision: parameter, method, limit and measured result. A line that says only “conforms” asks the reader to accept the conclusion without the evidence. Walnut peptides make that demand harder than a single-molecule ingredient, because the material is defined by two fractions rather than one identity.

Release parameters for walnut protein peptides
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan powder
IdentificationProtein and peptide profileConforms to the reference
ProteinKjeldahl nitrogen≥80.0%
Peptide contentHPLC peptide distribution≥70.0%
AshGravimetric≤5.0%
MoistureLoss on drying≤7.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Kjeldahl protein, the factor and the as-is basis

Kjeldahl digestion turns nitrogen into ammonia and measures it; the protein figure is that nitrogen multiplied by a conversion factor. The factor is a convention, not a measurement. Walnut protein is often calculated with 5.30 in nutrition work, while 6.25 is the general food convention, and the two do not give the same percentage from the same result.

A powder at 12.8% nitrogen reads 80.0% with the 6.25 factor and 67.8% with the 5.30 factor. Neither number is wrong; they answer different conventions. A certificate that omits the factor cannot be compared with another certificate, even when both describe the same powder.

The basis is a second convention. A result can be expressed on the powder as received or after subtracting moisture. At 6.0% moisture, an 80.0% as-is figure works out at about 85.1% on a dry basis. The catalog limit is written as ≥80.0% and leaves the basis to the specification, so the specification has to choose one and keep it across lots.

The peptide line needs the same discipline. The HPLC window defines what counts as a peptide, and the percentage should say whether it is a share of the powder or a share of the protein. Without the window, two suppliers can report 70% and mean different fractions.

Release limit versus batch result

Two columns are often conflated: the limit the lot must meet and the value the laboratory found. The first is the specification; the second is the evidence. A result column that repeats the limit has told the reader nothing about the lot.

The limit and the measured value belong in different columns
ParameterRelease limitResult column
Protein≥80.0%A measured percentage, with the factor and the basis
Peptide content≥70.0%A measured percentage, with the HPLC window and the chromatogram
Ash≤5.0%A measured percentage
Moisture≤7.0%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Microbiology is a count plus an absence statement, not a single pass word. Heavy metals are a figure for each element, not a total; a sum can hide the element that fails. The peptide line needs the chromatogram and the integration window as well as the percentage.

What moves between lots

The raw material moves first. Walnut variety, growing origin and the oil-pressing step change the meal that goes into hydrolysis, and that meal is the usual starting point for a walnut peptide. A press cake that still carries oil behaves differently from a thoroughly extracted meal, and the difference can show up in colour, odour and the fat that remains.

Hydrolysis sets the peptide distribution. Enzyme, dose, temperature, pH and time all shift how far the protein is broken down, and a higher degree of hydrolysis usually means more short chains but also more bitterness. Neutralisation sets the ash, because the salt formed from alkali and acid stays in the powder. Drying and milling set moisture, colour and mesh.

Appearance is a coarse check. The catalog range runs from off-white to light tan, and a shade inside that range is not an identity failure. A clear darkening is worth a question about the decolourisation step or the drying hold. Across lots, direction matters more than a single result: peptide falling, ash rising or moisture climbing with the season are trends worth investigating before a limit is breached.

The lot code on the certificate should match the pouch, the drum and the retained sample. Without that link, a good result cannot be attached to the pack in the warehouse.

When an outside test earns its place

An outside laboratory is useful for a new source, a first shipment into a regulated market, a label that depends on the peptide figure, or a disputed lot. The panel should target the decision, not repeat the whole certificate. Ask for Kjeldahl with the factor, HPLC peptide distribution with the chromatogram, amino acid analysis, ash, moisture, ICP-MS and microbiology.

Three walnut-specific checks are worth adding: the tree-nut allergen statement for the lot, because the declaration follows the source; a walnut protein ELISA or walnut-specific PCR when the source is in question, noting that hydrolysis can weaken both; and a risk-based aflatoxin panel, because walnut is a tree nut and the destination limit depends on the category and dose.

Ask the laboratory to report its detection limit for each screen. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample. Retain the sample that was tested and record the lot; if a result is contested, the referee needs the retained sample, the supplier's certificate and the specification.

What to compare between suppliers

Put six lines side by side: the walnut source and fraction; the protein factor and basis; the peptide window and chromatogram; ash and moisture; the tree-nut allergen statement; and the pack, lot code and retained sample. Two certificates that agree on protein but differ on factor or window are not describing the same powder.

The second layer is traceability. The certificate should name who manufactured the lot, which walnut material went in, and which hydrolysis, decolourisation, drying and milling steps were applied. The catalog specification sits on the walnut protein peptides product page. The tests that separate walnut from another plant protein are on the identity page; the grade choices are on the grades page; the HPLC method is described in the HPLC method note; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation