01 COA & batch testing

What the COA for undenatured type II collagen actually contains

Technical document 01 · Reviewed 2026-11-19 · Undenatured Type II Collagen

On this page
  1. The parameter list
  2. What the ELISA measures, and what the protein figure measures
  3. Limit, result and the word conforms
  4. What moves between lots
  5. When to send a sample to an outside laboratory
  6. What to compare between suppliers

A certificate for undenatured type II collagen answers two questions: is the powder type II collagen from chicken sternum, and how much of it is still native? The catalogue sets the ranges and methods; the batch COA confirms the lot. A protein figure without the ELISA has not measured the parameter the grade is sold on.

In one line

A type II collagen certificate proves the native content by ELISA with a type II specific antibody, beside the protein factor, the moisture, the ash and the contaminant panel.

The parameter list

CAS 9007-34-5 is the generic collagen CAS number, shared with collagen peptides and other collagen forms. It names the family, not the form, so it cannot separate a native powder from a hydrolysed one. The certificate is built on the parameters that can: native type II by ELISA, protein with its factor, moisture, ash, particle size and the contaminant panel. The table is the catalogue list; the release limits are agreed in the specification and repeated on every lot.

COA parameter list · chicken sternum undenatured type II collagen
ParameterMethodRelease limit
Type II collagenELISA, type II specific antibody10.0–20.0%
ProteinKjeldahl, N × 6.25≥50.0%
AppearanceVisualOff-white to light tan powder
Loss on dryingOven or infrared≤8.0%
AshGravimetric, furnace≤10.0%
pH (5% suspension)Potentiometry5.0–7.0
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and enrichmentAPC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent
Particle sizeSieving≥95% through 80 mesh

The source is a parameter without a number. Chicken sternum is a different label ingredient from bovine hide, fish skin or porcine tissue. The identity page covers how species and tissue are supported.

What the ELISA measures, and what the protein figure measures

The ELISA is an antibody assay. The antibody binds type II collagen and the signal is read against a native standard. It measures native content only if the epitope depends on the triple helix; a type II antibody raised against a linear sequence can bind denatured collagen as well. Where the method is conformational, heat-denature the powder and the protein remains but the result falls. That is why the antibody belongs in the specification.

Three details decide comparability. The extraction step must be stated, because native collagen is not freely soluble in neutral buffer and the extraction decides how much reaches the plate. The antibody must be named, because a type II reagent and a general collagen reagent answer different questions. The standard must be described, because a different calibrant carries a different bias. Ask for those lines on the method sheet, not only on the certificate.

Protein is a different measurement. Kjeldahl measures nitrogen and multiplies it by a factor; this specification uses N × 6.25, the general food factor. Collagen is often calculated with N × 5.55, which gives a figure about 11% lower on the same nitrogen. Neither factor measures type II collagen. At 10–20% native content, most of the 50% protein is other sternum protein, and the gap is expected. A certificate reporting protein alone has described the powder, not the grade.

Limit, result and the word conforms

A release limit is the window a lot must fall inside; a lot result is what the laboratory measured. A useful certificate shows both, with the method and basis beside each line. "Conforms to specification" without figures is a conclusion with no evidence, and it cannot be compared with another supplier's certificate.

The basis matters for moisture and protein. Loss on drying describes the powder at release; a dry-basis and an as-is figure differ by the moisture content, which can be several percent inside an 8.0% limit. The certificate should state the basis and the purchase specification should use the same one. A label claim calculated on the wrong basis can be out by more than the analytical variation.

This page describes a catalogue specification: what the material is expected to meet. The batch COA confirms the lot that ships. This site does not publish a batch result, a batch number or a customer’s certificate, and no page here should be read as one.

What moves between lots

Native content moves most, because the raw material is a biological tissue and extraction trades yield against structure. A gentler extraction keeps more helix and returns less material; a harsher one raises yield and lowers the ELISA. Standardization then blends lots to target, which is why the certificate is narrow even when the extract varied. The 10% and 20% grades are targets inside the same 10.0–20.0% range.

Moisture follows drying and the pack. Ash follows the mineral content of the tissue; a sternum powder carries more mineral than a hide powder, which is why the limit is 10.0% rather than 2.0%. Colour moves from off-white to light tan with drying temperature and time. Particle size moves with the mill and sieve, and a lot only just through 80 mesh flows differently from one well below it.

The ELISA also carries sampling error. A 25 kg drum is not necessarily uniform, and a sample from the top can differ from one drawn after rolling. Ask how the sample was drawn and whether the result is a mean of increments.

When to send a sample to an outside laboratory

Order an independent test when the source is new, when the first commercial shipment enters a regulated market, when the label says "native", or when a result is disputed. The useful panel answers the open question: native ELISA at a second laboratory with method and antibody named, protein with its factor, moisture and ash, ICP-MS for contaminants, and the microbiological set on the same sample.

An outside laboratory also settles a difference between two certificates. Send the retained sample, both certificates and the agreed specification, and ask for the tests that separate the explanations. If native content is the dispute, ask for spike-and-recovery on the same plate, because an extraction that under-recovers will read low on every sample. The quality page covers the batch file and the ICP-MS note the contaminant panel.

What to compare between suppliers

Put six lines side by side: the ELISA method, antibody and standard; the grade target and release window; the protein factor and basis; the moisture and ash limits; the source, tissue, origin and process temperature; and the contaminant and microbiological panel with methods. Two quotations that agree on "10%" but disagree on the other five are not quoting the same material.

The second layer is the record: which site made the lot, which raw material batch went in, which extraction and drying conditions applied, and what retained sample exists. A certificate can be accurate and still describe a lot other than the one that arrives. The lot number on the COA, the drum and the retained sample should match.

For the ranges, see the product page. The grade decision is on the grade page, the native evidence on the identity page, and the certificate definition in the COA glossary.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation