What the COA for soy protein peptides actually contains
The certificate for a soy protein peptide lot reports appearance, the protein and peptide profile, protein by Kjeldahl, peptide content by HPLC, moisture, ash, heavy metals, microbiology and particle size, with soy named as the source. Protein and peptide answer different questions, and each needs its method and basis beside it. The limits below describe the catalog grade; a batch certificate is the record for one released pack.
The protein result measures nitrogen; only the peptide result, the moisture and the soy statement show what kind of powder the lot is.
Reading the certificate line by line
A certificate is auditable when every line names the method and the limit. For a hydrolysate the identity line is not the protein percentage on its own: it is the combination of the soy source, the peptide profile and the declared hydrolysis. A row that says only “conforms” leaves the evidence out.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light yellow powder |
| Identification | Protein and peptide profile against reference | Conforms |
| Protein | Kjeldahl; factor and basis stated | ≥90.0% |
| Peptide content | HPLC; method and cut-off stated | ≥80.0% |
| Moisture | Loss on drying | ≤7.0% |
| Ash | Gravimetric, furnace | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
The certificate should name soy, and the specification should state that the material is hydrolysed soy protein, not isolate, concentrate or flour. A certificate that says only “plant peptide” has not identified the allergen.
Protein, peptide and the basis behind both
Kjeldahl gives nitrogen, and a conversion factor turns that nitrogen into a protein figure. Soy protein is often calculated at N × 6.25, the general food factor, while a soy-specific factor of 5.71 is also used in some methods. The two give different percentages for the same nitrogen result, so the factor belongs next to the figure.
The moisture basis matters as much. At the 7.0% moisture limit, a 90.0% protein result on a dry basis is 83.7% as-is. A certificate that prints 90.0% without the basis leaves the reader to guess whether the powder as weighed carries that figure. A 90.0% protein limit, 7.0% moisture and 5.0% ash cannot all sit at their limits in the same as-is powder, because they sum past 100%; in practice the protein figure is reported on a dry basis, and the certificate should say so.
Peptide content is a separate measurement. HPLC separates the peptide fraction from free amino acids and other small nitrogenous compounds, and the result depends on the column, the mobile phase and the molecular-weight cut-off. The catalog names HPLC and ≥80.0%, so the agreed method supplies the rest. Reporting the peptide figure against the sample or against the protein is a third choice that belongs on the certificate.
The two figures can be compared only on the same basis. At 90.0% protein and 80.0% peptide, the peptide fraction is at least 88.9% of the protein figure. The gap covers free amino acids, peptides below the cut-off and non-protein nitrogen; a wider gap is a question about the method, not automatically a reject.
Release limit versus batch result
The release limit is the gate; the batch result is the number the laboratory measured for that lot. The page needs both, in separate columns, with the method alongside. A result column that repeats the specification range has not reported a measurement.
| Parameter | Release limit | Result column |
|---|---|---|
| Protein | ≥90.0% | A measured percentage with the factor and the basis |
| Peptide content | ≥80.0% by HPLC | A measured percentage with the method and the cut-off |
| Moisture | ≤7.0% | A measured percentage |
| Ash | ≤5.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the sieve |
“Passes specification” is a conclusion the reader should reach from the numbers. Heavy metals need a figure per element, not a total; microbiology needs a count plus an absence statement. The soy declaration is a document statement rather than a pass or fail line, and it still belongs in the batch file.
What moves between batches
The soy raw material moves first: cultivar, growing region and the protein load of the flour or concentrate that feeds the hydrolysis. Hydrolysis conditions move the peptide figure. The enzyme, its dose, the hold time, the temperature and the pH set the degree of hydrolysis; a longer cut lifts peptide content and usually lifts bitterness too. Spray drying fixes moisture and bulk behaviour; milling and sieving fix the mesh result.
Colour is the least quantitative line. Off-white to light yellow covers a wide window; a darker tan can follow a hotter dry, a longer hold or a Maillard reaction with residual reducing sugar, while the protein figure still passes. A trend across lots — peptide drifting low, moisture climbing, ash rising — says more than one result near an edge. Ask for the retained sample and the process record before rejecting on appearance.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a disputed peptide figure or a label that depends on the soy statement. The useful panel is protein by Kjeldahl with the factor, peptide by HPLC with the method and cut-off, moisture, ash, ICP-MS for the heavy metals, microbiology, and a soy allergen statement that names the source.
An ELISA screen for soy protein can under-read a hydrolysate because hydrolysis has cut the epitopes the antibody recognises. That does not remove the declaration: the allergen statement follows the source, not the ELISA result. If the label claims non-GMO or identity-preserved soy, ask for the supporting certificate as well.
The retained sample and the tested sample should be the same material, and the report should carry the lot code. If a result is disputed, send the referee the retained sample and the agreed specification, and ask for the discriminating tests rather than a repeat assay.
What to compare between suppliers
Compare six lines: the soy source and hydrolysis; protein with its factor and basis; peptide with its method and cut-off; moisture and ash; heavy metals and microbiology; the allergen statement. If two quotations match on protein but not on the peptide method, they do not describe the same powder.
The second layer is traceability: who ran the hydrolysis, which soy material went in, and which drying and milling steps followed. The catalog grade is on the product page. The tests that separate a hydrolysate from an isolate are on the identity page; the allergen and market file on the compliance page; the methods are explained in the methods section; the release workflow is set out on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation