01 COA & batch testing

Reading the sea cucumber peptide COA: protein, peptide and size

Technical document 01 · Reviewed 2026-11-19 · Sea Cucumber Peptides

On this page
  1. The parameters on the certificate
  2. Protein, peptide content and the basis
  3. Release limit and batch result
  4. What moves between lots
  5. When an outside laboratory earns its fee
  6. Six lines to compare between suppliers

A sea cucumber peptide certificate reports protein by Kjeldahl, peptide content and molecular weight distribution by HPLC, moisture, ash, heavy metals, microbiology and particle size. Each line needs its method and its release limit, and the source has to be named. The figures are not interchangeable: protein is a nitrogen calculation, peptide content is an HPLC fraction, and the size distribution says how much of the material sits below 3,000 Da.

In one line

Protein, peptide content and molecular weight are three different measurements, so a sea cucumber peptide COA only reads correctly when each figure carries its method, its basis and its cut-off.

The parameters on the certificate

The specification has nine release lines. The table shows what each one means and which method produces it; it is the specification, not a lot result. A number without its method cannot be compared across suppliers.

COA parameter list · sea cucumber peptides, catalogue specification
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan powder
ProteinKjeldahl, factor and basis stated on the certificate≥90.0%
Peptide contentHPLC≥80.0%
Molecular weightHPLC size distribution≥80% below 3,000 Da
MoistureGravimetric≤7.0%
AshGravimetric, furnace≤5.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Two lines sit outside the table. The identification line, “protein and peptide profile conform”, is a conclusion drawn from the same HPLC work and should be supported by the chromatogram. The source line names the species and tissue and decides what the material can be called. The identity page sets out how that source line is supported.

Protein, peptide content and the basis

Kjeldahl measures nitrogen, not protein. The laboratory digests the sample, titrates the ammonia and multiplies the nitrogen by a conversion factor. That factor is a convention, so the certificate has to print it. A factor of 6.25 assumes 16% nitrogen; 5.55 assumes about 18%, so the same nitrogen result produces two different protein percentages.

The basis matters as much. The catalogue sets protein at ≥90.0%, moisture at ≤7.0% and ash at ≤5.0%. Read as-is, those limits add to 102%, so the protein figure must be on a dry basis for them to close. At 7.0% moisture, a 90.0% dry-basis result is about 83.7% as-is, the figure a formulation must use.

Peptide content is a separate measurement. The catalogue requires ≥80.0% by HPLC, and the method should define what counts as a peptide: the column, the calibration standards and the integration cut-off. A lot with 90.0% protein and 80.0% peptide has about 10 percentage points of protein that the peptide method does not count, which may be free amino acids, very small peptides or unseen nitrogen.

The molecular weight line needs the distribution, not only a pass mark. “≥80% below 3,000 Da” leaves up to 20% of the mass above the cut-off, and a lot can meet the gate with a high-molecular-weight shoulder that hazes drinks.

Release limit and batch result

The release limit is the boundary; the batch result is what the laboratory measured. Both belong on the page, in separate columns, with the method named. A result column filled with the specification range is a copy of the gate, not evidence about the lot.

What the result column should show
ParameterRelease limitResult column
Protein≥90.0% on the stated basisThe measured percentage, the factor and the basis
Peptide content≥80.0% by HPLCThe measured percentage and the HPLC method
Molecular weight≥80% below 3,000 DaThe measured distribution, not only the pass mark
Moisture and ash≤7.0% and ≤5.0%A measured percentage for each
Heavy metals and microbiologyPer element; counts and absenceA figure per element and the count or absence statement for the lot

“Conforms” is a conclusion, and the reader should be able to reach it from the numbers. For heavy metals, that means a figure for each element, not a single total. For microbiology, it means the count plus the absence statement. For particle size, it means the measured percentage through the 80 mesh sieve, not the word “fine”.

What moves between lots

The raw material moves first. Sea cucumber is a group of species, not one animal, and body-wall composition changes with species, season, size and whether the material is wild-caught or farmed. A plant taking mixed species produces a peptide whose amino acid profile, colour and ash move with the mix.

The hydrolysis moves next. Enzyme choice, dose, time and temperature decide how far the chains are cut and how much falls below 3,000 Da. Over-hydrolysis raises the free amino acid fraction and can lower the peptide content the HPLC method counts; under-hydrolysis leaves a high-molecular-weight shoulder. Filtration and drying then fix the moisture, the particle size and part of the colour.

Ash and colour are the quiet variables. The 5.0% ash limit is wider than a fish collagen limit because the body wall carries mineral material; a lot near the limit can meet the specification and still haze a clear drink or taste saltier. Colour moving from off-white to light tan is not an identity failure, but a shift outside that window deserves the batch record.

When an outside laboratory earns its fee

Order an independent test for a new species or supplier, a first shipment into a regulated market, a species or collagen label, or a disputed result. The useful panel is not a repeat of the certificate: protein by Kjeldahl with the factor, peptide content and size distribution by HPLC, an amino acid profile, ICP-MS and microbiology on one sample.

Arsenic deserves its own line in a marine material. Total and inorganic arsenic are different measurements, and a total does not say which fraction was found. Ask for the method and the destination limit. If the label names a species, ask how it was established; a highly hydrolysed powder is a difficult matrix for DNA, so the raw-material record and the process audit often carry more weight than a PCR result.

Chain of custody matters. The sample tested should be the sample retained, and the report should identify the lot. When a result is contested, give the referee the retained sample, the certificate and the specification.

Six lines to compare between suppliers

Put six lines side by side: species and tissue; protein with factor and basis; peptide content and HPLC method; molecular weight distribution; moisture, ash and particle size; contaminant and allergen statements. Two quotations that agree on protein but not the rest are not describing the same powder.

Traceability is the second layer: the certificate should name the manufacturer, the species and tissue, and the hydrolysis and drying steps. The specification sits on the sea cucumber peptides product page. The fish collagen COA shows how a collagen marker changes the document, and the analytical methods library explains the HPLC and ICP-MS work. The release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.