What the COA for fish collagen peptides actually contains
A fish collagen certificate answers four questions at once: how much protein the powder carries and by which factor it was calculated, how much hydroxyproline sits inside that protein, how the peptides are distributed by size, and which species and tissue the lot came from. The catalogue ranges set the window; the batch COA confirms where the shipped lot measured. Numbers without their methods cannot be compared with another supplier's.
A fish collagen certificate is only readable when the protein factor, the hydroxyproline figure, the SEC distribution and the species are stated together with their methods.
The parameters on the sheet
Nine lines carry the specification, each with the method beside it. A hydroxyproline result by HPLC and one by colorimetric assay are different measurements, and a molecular weight cut-off without the chromatographic method is a claim rather than a result. The table is the catalogue specification, not a lot result.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Protein | Kjeldahl, N × 5.55, dry basis | ≥90.0% |
| Hydroxyproline | HPLC | 8.0–12.0% |
| Molecular weight | SEC | ≥90% below 3,000 Da |
| Loss on drying | Gravimetric, 105 °C | ≤7.0% |
| Ash | Gravimetric, furnace | ≤2.0% |
| pH (5% solution) | Potentiometry | 5.0–7.0 |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and enrichment | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent |
Particle size belongs on the same certificate: ≥95% through 40 mesh, checked by sieve. It governs flow, dust and wetting, and it is one of the first lines to disappear when a specification is copied from another product. The species and tissue produce no number but belong on the sheet as well: fish skin, fish scale and bovine hide are separate label ingredients, and the CAS number, 9007-34-5, names collagen as a class without naming the species. The identity page sets out how that declaration is supported.
The factor behind the protein figure
The Kjeldahl result is a nitrogen figure, not a protein figure. The digest is titrated and the nitrogen multiplied by a conversion factor, a convention for a class of material rather than a property of the powder. Collagen uses N × 5.55 because it carries close to 18% nitrogen; a general food protein uses N × 6.25, which assumes 16%.
The same nitrogen result therefore gives two percentages. Because 6.25 is about 12.6% larger than 5.55, a 90.0% result becomes roughly 101% when the factor changes. The second figure does not mean a richer powder; the convention changed, not the material. A certificate that omits the factor cannot be compared with one that names it.
The basis matters as much. The catalogue figure is on a dry basis; at the 7.0% moisture limit, 90.0% dry corresponds to about 83.7% as-is, which is the number a formulation has to use. Mixing the two bases introduces a several-point error before any analytical variation is counted.
Kjeldahl also cannot separate peptide nitrogen from urea or ammonium nitrogen, which is why the protein figure is read beside the hydroxyproline result rather than alone.
Range, limit and lot result
A release limit is the window a lot must fall inside; a lot result is what the laboratory measured. Both belong on the sheet, with the method named. “Conforms” on its own is a verdict with no evidence attached.
The molecular weight line needs more than a pass mark. The specification can require ≥90% of the mass below 3,000 Da, and a lot can meet that gate while sitting at the high end of it. The certificate should report the measured distribution, not only the cut-off, because the same gate can hide a powder that dissolves slowly and one that dissolves cleanly.
The specification described here is a catalogue specification. It sets what the material should meet; the batch COA confirms the lot that ships. No page on this site reports a batch number or a lot result.
Lot-to-lot movement
The raw material moves first. Skin from a filleting line is wet and fatty, and its composition depends on the species, the season and how quickly it was chilled. A plant running several species produces a peptide whose hydroxyproline and amino acid profile shift with the mix, even when the hydrolysis programme is unchanged.
Hydrolysis moves next. Time, temperature and enzyme dose decide how far the chains are cut and how much of the material falls below 3,000 Da. How much of the fine fraction survives depends on filtration and concentration; the spray dryer then fixes the moisture, the particle size and some of the colour.
Smell is the hardest thing to put a number on, and often the most informative. A marine or broth note can strengthen with moisture and with storage temperature, and a lot can pass every number while smelling unlike the previous drum. Ask for the retained sample and the storage history rather than rejecting the lot on the protein figure.
When an outside laboratory earns its fee
Go outside when the source is new, when the first commercial lot is heading into a regulated market, or when the label names a species the certificate does not prove. The panel that closes the open question is small: hydroxyproline and the amino acid profile for collagen identity, SEC for the distribution, a species-specific PCR on the raw tissue or a validated finished-product method, and ICP-MS for contaminants on the same sample.
A dispute is another reason to go outside: send the retained sample, the certificate and the specification, and ask only for the tests that separate the competing explanations. The quality page shows how the batch file and the retained sample travel together.
Six lines to compare
Put six lines side by side: the species and tissue; the protein figure with its factor and basis; hydroxyproline with its method; the SEC distribution with its method; moisture, ash, pH and particle size; and the allergen statement with the country of origin. Two quotations that agree on the protein percentage and disagree on the other five are not quoting the same material.
Behind the certificate sits the record: the plant that ran it, the raw batch behind it, the hydrolysis and drying record, and the sample kept from it. An accurate certificate can still belong to a different drum from the one that arrives, so the lot number on the COA, the drum and the retained sample should match.
For the ranges themselves, see the fish collagen peptides product page. The source decision is on the grade comparison page, the regulatory file is on the compliance page, and the COA glossary entry explains what the document is.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation