What the COA for fish protein peptides reports
A fish protein peptide certificate reports protein with its nitrogen factor and basis, the peptide fraction with its HPLC window, ash, moisture, heavy metals, microbiology and particle size. Each line carries a method and a release limit, and the batch result belongs in its own column. The tables below hold the catalog specification; the certificate confirms a particular lot.
The protein figure is a nitrogen calculation and the peptide figure is an HPLC fraction, so the certificate means little without the factor, the basis and the window.
What the sheet has to show
A certificate is auditable when every row answers three questions: what was measured, by which method, and against which limit. A line that reports only “conforms” replaces the measurement with an assertion.
Protein and peptide are the rows most often confused. Protein is a nitrogen calculation; peptide is a chromatographic fraction. They are not interchangeable, and a specification needs both.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan powder |
| Protein | Kjeldahl, nitrogen factor stated | ≥80.0% |
| Peptide content | HPLC, molecular-weight window stated | ≥70.0% |
| Ash | Gravimetric, furnace | ≤10.0% |
| Moisture | Gravimetric, 105 °C | ≤7.0% |
| Identification | Protein and peptide profile against the reference | Conforms |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
Read the ash line with the source in mind. The ≤10.0% window is wide, and a lot near the top is saying something about the raw material or the neutralisation step that protein does not.
Protein basis, the nitrogen factor and the peptide window
Protein is calculated: nitrogen multiplied by an agreed factor. The factor belongs beside the result. A general food-protein factor of 6.25 is usual for fish muscle; collagen is calculated at 5.55. The same nitrogen read with the two factors differs by about 13%, enough to move a lot across the 80.0% gate. The certificate should name the factor, and the specification and label should use the same one.
The basis is the other half. As-is and dry-matter results describe different powders. A lot at 80.0% as-is with 7.0% moisture is 86.0% on the dry basis (80.0 ÷ 0.93). Neither figure is wrong; a quotation that compares one with the other is comparing different numbers.
Peptide content has its own window and basis. The HPLC method defines a molecular-weight range, integrates that fraction and reports it. “Peptide ≥70%” without the window and integration method is a headline. Peptide should not exceed protein: at the limits and on the same basis, 70.0% against 80.0% means at least 87.5% of the protein mass is peptide.
Ash and moisture close the balance. At 80.0% protein, 10.0% ash and 7.0% moisture, about 3% remains for fat, carbohydrate and other material. A lot at 80% protein, 10% ash and 10% moisture has an arithmetic problem before identity is discussed.
The limit, the result and the evidence
The limit defines what the lot had to meet; the result records what the laboratory found. Keep them in separate columns with the method alongside, because a result column that repeats the specification has recorded no measurement.
| Parameter | Release limit | Result column |
|---|---|---|
| Protein | ≥80.0%, factor and basis stated | A measured percentage, with factor and basis |
| Peptide | ≥70.0%, window stated | A measured percentage, with window and method |
| Ash | ≤10.0% | A measured percentage |
| Heavy metals | Per element | A separate figure in mg/kg for every metal |
| Microbiology | Counts and absence | The plate count plus the absence result for the lot |
A pass statement is only as good as the figures behind it. Each metal needs its own result, and the microbiological line needs a count plus the absence finding.
What moves between batches
The raw material moves first. Fillet trimmings, frame material and mixed by-product streams differ in species mix, season, nitrogen and ash. A lot from a new source can meet every limit and still behave differently in a blend.
Hydrolysis moves the peptide curve and the taste. A longer hydrolysis raises the short-chain fraction and can make the flavour more savoury or bitter; a shorter one leaves larger peptides and different foaming. Drying moves moisture, density and colour; milling moves the 80 mesh result without changing chemistry.
Colour and odour are the least quantitative lines and often the most revealing. Off-white to light tan is a wide window, and a fish note is normal. A batch that turns darker or more rancid can point to oxidised lipid while protein still passes; ask for the batch and raw-material record before rejecting on appearance alone.
Look at the trend across lots rather than a single result near a limit: protein drifting low, ash climbing, moisture rising. Check that one lot code links the pouch, the drum and the retained sample.
When to order an outside test
Commission an outside test for a new source, a first regulated-market shipment, a species claim the certificate does not prove, or a disputed result. The panel should add to the certificate rather than repeat it: Kjeldahl with the factor, HPLC peptide distribution, an amino acid profile including hydroxyproline, ICP-MS, microbiology and a species check where a species is named.
For a fish source, add two questions. Histamine is a risk-based test for susceptible species and a failed cold chain; total arsenic is on the catalog panel, and a marine source may warrant speciation if the destination asks. Neither replaces the protein or peptide data.
Request the detection limit with every screen; a “not detected” entry means little until that limit is stated. Keep the chain of custody intact: test the retained sample, and settle a dispute by a joint re-test rather than a second run of the same method.
Six points for a supplier comparison
Compare six points: species and tissue; protein factor and basis; peptide window and method; ash and moisture; the fish allergen statement; pack and lot code. Two offers that match on protein but diverge on factor or window describe different powders.
Traceability is the next layer: who made the lot, which raw material and hydrolysis route, which drying and milling steps. Start with the fish protein peptides product page for the catalog; the identity page covers the source evidence; the compliance page covers the allergen and market file; the methods library holds the assay notes; the quality page sets out the release workflow.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation