How to prove a zinc sulfate lot is the monohydrate
A monohydrate lot is identified by agreement, not by one number: the document names CAS 7446-19-7, complexometric titration returns 35.0–38.0% zinc, a sulfate determination confirms the anion, a water determination fits the monohydrate rather than the heptahydrate, and IR or X-ray diffraction matches the monohydrate reference. Zinc alone cannot separate the hydrates, because the heptahydrate returns 22.7% and the anhydrous salt 40.5%.
A monohydrate lot is proved when the zinc, sulfate and water results agree and the solid-state pattern matches, not by a single zinc percentage.
Identity evidence, layer by layer
A name on a certificate is a claim; the tests are the evidence. The table separates the questions. A supplier who answers only the first question has described the label, not the drum.
| Evidence | Question it answers | Method | What it establishes |
|---|---|---|---|
| Paperwork | Does the document name the hydrate? | Name, CAS, formula | Only the label |
| Zinc | Is the zinc figure right? | Complexometric titration | Zinc content, not hydration |
| Sulfate | Is the anion sulfate? | Titration or gravimetric sulfate | Confirms the salt and balances the mass |
| Water | Is it the monohydrate? | Total water, plus LOD for free moisture | Hydration state |
| Crystal | Is the solid the monohydrate? | IR; XRD for a dispute | The hydrate in the drum |
The catalog identity is a conformity statement: zinc and sulfate conform. It is a workable release gate, but it does not put a number on the sulfate or the water. If the hydrate is challenged, ask for those numbers and for the diffraction pattern.
What the zinc, sulfate and water figures should show
The formula sets the expected figures. Pure ZnSO4·H2O contains 36.43% zinc, 53.53% sulfate and 10.04% water. Zinc and sulfate are present in a 1:1 molar ratio, which is a mass ratio of 36.43 ÷ 53.53 = 0.681. One gram of zinc corresponds to 179.45 ÷ 65.38 = 2.745 g of salt.
The catalog window of 35.0–38.0% zinc maps to 96.1–104.3% of the monohydrate formula. A result at the top means less water than the formula; a result at the bottom means more water or a diluent. That is why the zinc line is read with the sulfate and the water, not alone: high zinc with low water suggests an anhydrous fraction, low zinc with normal sulfate suggests a diluent, and high water with low zinc suggests surface moisture.
The water line needs a note. The catalog's LOD is a free-moisture test; the monohydrate keeps its crystal water until above 238 °C, so the 10.0% does not show up there. To prove the hydrate by mass balance, order total water as a separate determination.
A hydrate blend shows the same way. Monohydrate plus anhydrous salt can sit inside the zinc window while its total water falls with the anhydrous share; adding sodium sulfate lowers zinc and introduces sodium. Zinc reports the element, sulfate reports the anion, water reports the hydrate.
IR and diffraction: checking the solid
IR is the usual release check: it is quick, and it sees the sulfate and water bands together. With a reference it can distinguish the monohydrate from the heptahydrate, though the spectra are close and a library hit is only as reliable as the library. Name the reference and the band region.
X-ray diffraction is more direct: does the solid give the monohydrate pattern? Each solid has its own unit cell, so the peaks sit in different places and a mixture shows both sets. XRD does not measure purity or water, but it is direct evidence that the crystal is the hydrate named on the sheet.
A match needs the reference pattern and a detection limit. A report that says only “XRD conforms”, with no pattern and no reference, adds little. Order it when a hydrate claim is challenged, or when two sources are being weighed for a specification change.
What substitution looks like
| What goes wrong | How the figures move | Signal | Test |
|---|---|---|---|
| Heptahydrate supplied as monohydrate | Zinc falls; total water rises | Zinc near 22.7%; water high | Titration, total water, XRD |
| Anhydrous salt blended in | Zinc rises; total water falls | Zinc above 38.0%; water low | Titration, total water, XRD |
| Sodium sulfate added | Zinc falls; sodium rises | Sodium present; sulfate near normal | ICP-OES, mass balance |
| Magnesium sulfate substituted | Zinc falls; magnesium rises | Magnesium present; different pattern | ICP-OES, XRD |
| Zinc oxide blended in | Insoluble zinc; sulfate falls | Hazy solution; sulfate below 53.5% | Solubility, sulfate, XRD |
| Technical grade | Heavy metals rise | Pb, Cd or As over the limit | ICP-MS on the lot |
| Free water | LOD climbs; caking | LOD over 1.0%; sieve blocked | LOD, sieve, flow |
Zinc sulfate is a commodity, so the usual problems are grade and hydrate rather than a clever fake. A technical grade can pass zinc and fail the metals; a heptahydrate can pass a wide zinc window and fail the water. Colour is the weakest clue: white to off-white covers every hydrate, and a yellow tint points to iron.
Identity lines for the specification
- “Zinc sulfate monohydrate, CAS 7446-19-7, ZnSO4·H2O.”
- “Zinc 35.0–38.0% by complexometric titration; name the basis.”
- “Zinc and sulfate conform; report the sulfate result.”
- “Loss on drying ≤1.0%; total water by Karl Fischer on request.”
- “IR versus a named reference; XRD if a dispute arises.”
- “Heavy metals by ICP-MS, element by element; microbiology as listed.”
- “No hydrate or grade change without written change control.”
Five questions to settle before approval
- What hydrate is this, and which CAS number is printed on the certificate?
- What zinc and sulfate results were obtained, and by which methods?
- What is the total water, and does the mass balance close?
- May we see the IR spectrum and, if needed, an XRD pattern with its reference?
- If the lot is challenged, will you join a retest of the retention sample?
An identity file is these answers together. One zinc percentage is not the file. The product page has the catalog data; the heptahydrate page has the other hydrate's figures; the COA page shows where each result sits; the grades page compares the two; the methods library covers titration, water and diffraction; the quality page covers release and retest.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation