01 COA & batch testing

What the COA for sodium citrate dihydrate actually contains

Technical document 01 · Reviewed 2026-11-19 · Sodium Citrate

On this page
  1. The certificate as a test report
  2. Anhydrous basis, as-weighed sodium and the water line
  3. Release limit versus batch result
  4. What moves between batches
  5. When an outside test is worth ordering
  6. Six points of comparison between suppliers

A sodium citrate dihydrate certificate reports appearance, identification by infrared spectrum and the citrate reaction, assay by titration on the anhydrous basis, the sodium figure, water by Karl Fischer, the pH of a 5% solution, the heavy-metal panel, microbiology and particle size. The assay and the sodium figure are two views of the same salt, and neither is complete without the water result beside it. The ranges below are the catalog specification; a batch certificate is the document that confirms one pack.

In one line

The assay is reported on the dry matter and the sodium figure on the powder as weighed, so the water result is the line that ties the two numbers to one salt.

The certificate as a test report

A certificate is auditable when each line carries what was measured, the method behind the number, and the limit it was released against. A row that says “conforms” asks the reader to accept a conclusion without the evidence. Here the identity row fixes the hydrate and the salt form, the assay row fixes how much trisodium citrate is present, and the sodium row cross-checks both.

Identity, assay, water and contaminants · sodium citrate dihydrate
ParameterMethodRelease limit
AppearanceVisualWhite crystals or powder
IdentificationInfrared spectrum; citrate reactionConforms to the reference
Assay, anhydrous basisTitration99.0–100.5%
Sodium, as weighedCalculated from the assay; ICP-OES on request22.5–24.0%
WaterKarl Fischer11.0–13.0%
pH, 5% solutionPotentiometric7.5–9.0
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyAerobic plate count; absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

The pH row is not in every catalog, but the alkalinity is part of how the salt behaves in a formula; agree a window and report a measured value when the application depends on it.

Anhydrous basis, as-weighed sodium and the water line

Sodium citrate is assayed on the anhydrous basis: the laboratory measures the powder as received, then divides by the dry matter. A lot at 99.2% anhydrous with 12.0% water contains 99.2 × 0.88 = 87.3% sodium citrate as weighed. The gap is crystal water, and it is why an as-is percentage and an anhydrous percentage describe different powders.

The sodium line is reported on the powder as weighed, and the arithmetic explains the window. Three sodium ions in a molecule of 294.10 g/mol give 23.45% sodium in the pure dihydrate and 26.72% in the anhydrous salt. The catalog range of 22.5–24.0% is therefore a hydrate figure; a sodium result read against an anhydrous assay would look low by roughly the water fraction. If the certificate does not say which basis the sodium row uses, ask before comparing two suppliers.

Water by Karl Fischer should sit between 11.0% and 13.0%, against 12.25% by formula. A result near 11.0% is a drier crystal; one near 13.0% leaves less room for pickup in a humid warehouse. Loss on drying at 150–180 °C is a different test from Karl Fischer, because it also drives off any residual volatile; the certificate should name the method it used.

Release limit versus batch result

The limit is the boundary a lot has to meet; the result is the number the bench actually obtained. Put both in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not a result.

What the result column should contain
ParameterRelease limitResult column
Assay99.0–100.5% anhydrousThe percentage measured, with basis and method named
Sodium22.5–24.0% as weighedThe figure measured, with its basis named
Water11.0–13.0%A measured percentage by Karl Fischer
Heavy metalsPer elementOne result per element, in mg/kg
MicrobiologyCounts and absenceThe count, plus the absence statement
Particle size≥95% through 40 meshThe percentage that passed the sieve

“Passes specification” is a conclusion, and the reader should be able to reach it from the numbers alone. A total for heavy metals hides the element that matters; microbiology needs a count beside the absence statement; the assay needs a value, a basis and a method.

What moves between batches

Crystallisation and drying move the water result first and the anhydrous assay second. Milling and sieving move the particle-size figure without changing the chemistry, so a new mill can change the certificate while the salt is the same material. The pH of a 5% solution moves with residual acid or a trace of carbonate, and either can be visible on the certificate before it is visible in the powder.

Caking is the failure a certificate cannot show. A lot released at 13.0% water and stored in a humid warehouse can arrive as a lump; the assay and the water result were inside their limits at release, and the pack and the store did the rest. Ask for the water result and the store history together.

A trend across lots says more than one result at an edge: water climbing, the anhydrous assay drifting, or pH moving in the same direction. Four items carry one lot code: the certificate, the pouch, the drum and the retained sample.

When an outside test is worth ordering

An outside test earns its place on a new source, a first export shipment, a disputed hydrate or a chloride question. The panel worth ordering is narrower than a repeat of the certificate: infrared identity, titration, Karl Fischer water, sodium by ICP-OES, the metals panel by ICP-MS, chloride by ion chromatography or titration, and microbiology. A citrate figure by HPLC adds an independent view of the anion when the titration result is challenged.

Add X-ray diffraction when the hydrate state is in dispute or a crystalline chloride is suspected. Every screen should carry its detection limit, because “not detected” without one describes the laboratory's sensitivity rather than the drum.

Keep the sample that was tested and the sample that was retained identical, and make sure the report names the lot. If a result is contested, hand the referee the retained sample, the certificate and the specification, and ask for the discriminating tests on hydrate and chloride instead of a rerun of the same assay.

Six points of comparison between suppliers

Compare six things: the hydrate and its CAS number; the assay and the basis it is calculated on; the sodium figure and its basis; water; the contaminant and microbiology results; the pack and its lot code. If two quotations agree on assay but disagree on hydrate or basis, they describe different powders.

The second layer is traceability: who manufactured the lot, which drying and milling steps were applied, and which specification revision is on file. Catalog ranges are listed on the product hub. For the tests that separate the hydrate from the anhydrous salt, see the identity page; the market file is set out on the compliance page; titration and water methods are described in the methods library; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation