01 COA & batch testing

What the COA for potassium chloride actually contains

Technical document 01 · Reviewed 2026-11-20 · Potassium Chloride

On this page
  1. The certificate as a test report
  2. Dried basis, the titration and the potassium line
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a potassium chloride lot reports appearance, identification of potassium and chloride, assay by titration, potassium by flame photometry, loss on drying, the heavy-metal panel, microbiology and particle size. The assay and the potassium figure answer different questions: the assay measures the salt against a titrimetric standard, while the potassium line measures the element itself. The limits below are the catalog specification, not a batch result; the lot certificate confirms a particular pack.

In one line

The assay and the potassium figure describe the same lot from two directions, and neither is complete without its method, its basis and the loss on drying beside it.

The certificate as a test report

A certificate is only as useful as its weakest line. Each row needs the parameter, the method and the release limit; a row that says “conforms” with no method asks the reader to trust a conclusion. The table below is the catalog gate, not a batch record, and the measured result belongs beside the limit rather than in place of it.

The identity pair is potassium and chloride: a lilac flame and flame photometry for potassium, a white silver chloride precipitate for chloride. Neither test rules out sodium chloride, which is why the potassium figure is read against the assay.

Release tests · potassium chloride
ParameterMethodRelease limit
AppearanceVisualWhite to off-white powder
IdentificationPotassium flame test; chloride precipitationConforms to the reference
AssayTitration99.0–101.0%
PotassiumFlame photometry52.0–55.0%
Loss on dryingGravimetric≤0.5%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Dried basis, the titration and the potassium line

Potassium chloride has no water of crystallisation. The loss on drying is surface moisture, not a hydrate, and the limit is small at ≤0.5%. Small is not zero: at 0.5% water, a 100.0% assay on the dried basis is 99.5% of the powder as weighed. The certificate should print the basis and the measured loss on drying beside it.

The assay is commonly argentometric. Chloride is precipitated with silver nitrate and the result is calculated as potassium chloride, which means the number follows the chloride, not the potassium. A trace of sodium chloride adds chloride without adding potassium, so it can lift the calculated assay while the potassium figure stays low. The flame-photometry line is the independent check. Pure potassium chloride is 52.45% potassium, so a 99.5% assay corresponds to about 52.19% potassium.

The potassium range here is 52.0–55.0%, which is wider than the assay range can explain. Even a 101.0% assay only supports about 52.97% potassium; a result near 55.0% is a reason to ask how the flame photometry was calibrated, diluted and standardised, not evidence of a richer salt. A 101.0% result is a method allowance, not a purity above 100%. Ask which titration, which end-point and which potassium standard.

Release limit versus batch result

The release limit is the boundary for the lot; the batch result is what the laboratory measured on that lot. A result column filled with the specification range is a copy of the gate, not evidence about the powder. The identity row is qualitative: say what was observed, not only that the sample passed.

What the result column should contain
ParameterRelease limitResult column
Assay99.0–101.0%, dried basisA measured percentage and the basis
Potassium52.0–55.0%A measured percentage by flame photometry or ICP-OES
Loss on drying≤0.5%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot
Particle size≥95% through 80 meshThe measured percentage through the sieve

“Conforms” is a conclusion the reader should be able to reach from the numbers. For heavy metals the evidence is a figure per element, not one combined total; for microbiology it is a count plus an absence statement. A certificate that reports a sum has hidden the element that matters.

What moves between batches

The source moves the trace chemistry. Potassium chloride is recovered from sylvinite or from brine, and both routes can leave sodium, sulfate and bromide in the finished salt. Sodium is the common companion because the two chlorides crystallise together. A low potassium figure with a high sodium result points to sodium chloride; a brine source is a reason to ask for sulfate and bromide by ion chromatography, neither of which is in the catalog.

Drying and milling move the rest. The 80 mesh figure is a finishing specification, so it changes when the mill, the sieve or the granulation step changes. Moisture pickup in a humid filling room can cake the powder and alter its flow before the pack is sealed. Colour is the weakest line: white to off-white is a wide window, and a grey or yellow tint is a question about the source and the filters, not an identity failure by itself.

The lot code on the certificate should match the pouch, the drum and the retained sample. A certificate that cannot be tied to a pack describes a sample, not a delivery.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a potassium figure that does not fit the assay, or a disputed identity. The useful panel is not a full repeat of the certificate: assay by argentometric titration, potassium by flame photometry or ICP-OES, chloride by ion chromatography, loss on drying, ICP-MS for the metal panel, microbiology, and the pH of a 5% solution. Add X-ray diffraction when sodium chloride is suspected, and sulfate and bromide when the source is brine.

Ask the laboratory to state its detection limit for each screen. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample. The sample tested should be the retained sample, the report should name the lot, and a disputed result should be settled on the sealed pack rather than on an open scoop.

The methods index describes the titration and photometry techniques; the quality page covers the release and retained-sample workflow.

What to compare between suppliers

Put six lines side by side: the salt and CAS number, the assay with its basis, potassium and chloride on the same lot, the loss on drying, the contaminant and micro panels, and the mesh with the pack and lot code.

The second layer is traceability: the certificate should name the source and the process steps. The catalog specification sits on the potassium chloride product page. The tests that separate the salt from sodium chloride are on the identity page; the mesh and granulation choices are on the grades page; the difference from the citrate is set out on the chloride versus citrate page.