What the COA for calcium citrate anhydrous contains
The release certificate for calcium citrate anhydrous has to answer two questions that a calcium result alone cannot: is the anion citrate, and is the powder free of the tetrahydrate's water? The catalog sets calcium at 21.0–24.0% by complexometric titration, loss on drying at ≤1.0%, calcium and citrate identification, 80 mesh, the heavy-metal panel and microbiology. The batch COA reports those lines for one lot; the limits below are the specification, not a result.
The calcium window and the water limit have to be read together: 21.0–24.0% calcium is consistent with the anhydrous salt, and a loss on drying at or below 1.0% is what keeps the tetrahydrate out.
The certificate as a test report
Read the certificate as a chain of evidence. The identity block comes first: the calcium reaction, the citrate reaction and the infrared spectrum. The quantitative block follows: calcium by titration and loss on drying. The safety block closes it: heavy metals, microbiology and mesh. A certificate that prints only the middle is a potency sheet, not an identity document.
Each row should carry a method and a limit, not only a verdict. “Conforms” is acceptable for a comparative identification test; it is not acceptable for calcium, water or mesh, where a number and a basis are needed.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | White to off-white powder |
| Identification | Calcium reaction, citrate reaction and infrared spectrum | Conforms to reference |
| Calcium (Ca) | Complexometric titration | 21.0–24.0% |
| Loss on drying | Gravimetric, conditions stated | ≤1.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
Calcium, citrate and the water figure
Complexometric titration reports elemental calcium. EDTA binds the calcium ion in an alkaline buffer, an indicator marks the endpoint, and the calculation uses the sample weight and the titre. The number is real, but it is not specific: carbonate, oxide and the tetrahydrate all put calcium into the same flask. The citrate test and the water line carry the specificity.
The catalog method line also names citrate titration. Where the laboratory reports citrate quantitatively, read it as a second measurement; where it reports “citrate conforms”, the infrared spectrum is doing the work. The certificate should say which one was run, because a reaction and an infrared match prove presence, not proportion.
Loss on drying is the hydrate gate. The anhydrous limit is ≤1.0%; the tetrahydrate limit is ≤13.0%. The drying temperature and time belong in the method column: a 1.0% limit run at 105 °C for two hours is a different test from one run at 150 °C to constant weight. A water result near 12% is not an anhydrous lot with a problem; it is a different material.
Check the basis on the calcium line. The catalog window applies to the material as sold. If the certificate also gives a dried-basis figure, the water explains the gap: 23.7% as sold with 0.6% water becomes 23.84% dried. A result near 24.0% is close to the stoichiometric 24.1%; a result near 21.2% is at the floor of the window and needs the water line before the hydrate is accepted.
Release limit versus batch result
The specification defines the gate; the batch result records what was measured. They belong in separate columns, with the method beside each, so a reviewer can reproduce the release decision.
| Parameter | Release limit | Result column |
|---|---|---|
| Calcium | 21.0–24.0% as sold | A measured percentage, with the method and the basis |
| Loss on drying | ≤1.0% | A measured percentage, with temperature and time |
| Identification | Conforms to reference | The calcium and citrate tests that were run |
| Heavy metals | Per element | A separate mg/kg figure for each metal |
| Microbiology | Counts and absence | The plate count plus the absence wording for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the named sieve |
A total heavy-metal figure is not a substitute for the four elements: a sum hides which metal is present. For microbiology, a count without the absence statement is half a result. A certificate missing one of those lines is incomplete, not automatically failed.
What moves between batches
Water is the variable that moves first. A lot that has absorbed surface moisture reads higher on loss on drying and lower on calcium as sold, while the dried-basis calcium stays close to the same value. A lot that is fully anhydrous reads near zero water and close to 24% calcium. The pair of lines tells you which end of the range the lot is on, and the water line is the only one that shows it.
Mesh and flow follow the mill and the sieve, so they can change with no change in chemistry. Colour follows the calcium source and the drying step; a grey cast is not an identity failure, but a consistent drift across lots deserves a question about the source. The lot code should follow the certificate, the pack and the retained sample.
When to order an outside test
A referee laboratory earns its place for an unfamiliar source, a first entry into a regulated market, a hydrate dispute, or a citrate figure the supplier does not report. The useful panel is targeted: calcium by titration, citrate by reaction and infrared or by HPLC, loss on drying under a named procedure, ICP-MS for the metals and a micro count.
Add thermogravimetry or Karl Fischer when the water form is the dispute, and X-ray diffraction when crystalline carbonate or oxide is suspected. These methods answer different questions: loss on drying sees everything volatile, Karl Fischer sees water, and thermogravimetry shows the temperature at which the mass leaves. A “not detected” line is only as strong as its stated detection limit.
What to compare between suppliers
Set out six columns: hydrate and formula; calcium with method and basis; citrate identification; loss on drying with its conditions; metals and microbiology; mesh and lot code. If two offers agree on calcium but not on the hydrate or the water, they are not the same product.
Then check traceability: the manufacturer, the plant, the lot and the retained sample. A valid certificate that cannot be tied to the drum on the dock is a paperwork failure, not a quality result.
The catalog figures are on the calcium citrate anhydrous product page. The hydrate comparison is on the grade page; the tests that separate the forms are on the identity page; the method notes are collected under analytical methods; release practice is on the quality page.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation