How we prove an algal DHA oil lot is DHA
An algal DHA oil lot is identified by its whole fatty-acid profile, not by a single DHA percentage. The GC run should show DHA at 35.0–45.0%, EPA at or below 3.0%, a measurable DPA fraction and the saturated and monounsaturated acids that belong to the algal oil; a sterol pattern and the oxidation figures then separate a genuine algal oil from a blend. The DHA figure alone can be reached by adding DHA to another oil.
DHA can be added to an oil; only the whole fatty-acid profile, the sterol pattern and the oxidation figures show that the oil is algal and has been kept.
The four identity layers
A certificate can carry the right name and still leave the oil unproven. Each layer below answers a different question, and each needs its own measurement. A supplier who stops at the first has shown paperwork, not a sample.
| Stage | Question it answers | Measurement | What it shows |
|---|---|---|---|
| Document | Is the material named? | Product name, algal source, CAS 6217-54-5 | Paperwork only |
| Chromatography | Is the fatty-acid profile algal? | GC-FID of methyl esters, full profile | The oil's composition, not its source |
| Sterols | Is another oil present? | Sterol profile by GC | Vegetable-oil dilution |
| Condition | Has the oil been kept? | PV, p-AV, FFA, moisture, appearance | Oxidation and hydrolysis |
The ratios inside the profile
The profile is a set of ratios, and the ratios are what a single DHA result hides. At the lowest DHA figure and the highest EPA figure the catalog allows, 35.0% and 3.0%, the ratio is about 12:1; at 45.0% DHA with EPA at 3.0% it is about 15:1. An algal oil is DHA-dominant in that way. A fish oil is not: it carries a larger EPA share, so a DHA/EPA ratio far below the algal range is a signal that the source or the blend has changed.
The rest of the profile matters as much. Algal oil carries palmitic and myristic acids and a low level of oleic acid; a large linoleic acid peak points to a vegetable oil such as sunflower or soy, which is a common diluent. DPA is reported in the same run, and its presence at a low level is consistent with algal oil; it is not a release limit in the catalog. None of these ratios is a purity assay on its own. They are a screen that says whether the DHA figure is plausible for the oil, and they become evidence when the chromatogram is supplied with the result.
Check the basis before comparing ratios. A profile normalised to peak area describes the composition of the fatty-acid fraction, while an internal-standard result describes grams per 100 g of oil. The two are close when the oil is pure and diverge when it is diluted or when the injection is off. The certificate should name the basis, and the ratios should be calculated from the same run.
X-ray diffraction and the solid-state question
An oil has no crystal lattice at room temperature, so X-ray diffraction is not an identity test for algal DHA oil as sold. The technique answers a solid-state question: is a powder crystalline, and does its pattern match a reference? It belongs to the spray-dried form, where it can distinguish a crystalline carrier or a crystalline fraction from an amorphous matrix, and it can compare lots from two sources. It does not measure the fatty-acid profile and it does not prove the algal source.
For the oil, the practical physical checks are different. FTIR confirms the ester and unsaturation bands, a cold test describes how the oil crystallises when chilled, and viscosity and appearance describe handling. None of them replaces the GC profile. If a supplier offers an XRD “match” for an oil, ask what was actually tested; the answer is usually the carrier or a crystallised fraction, not the oil in the bottle.
Substitutions and their signals
| Adulterant | What it does | Signal | Test |
|---|---|---|---|
| Vegetable oil | Dilutes DHA; adds linoleic and oleic acids | Large C18:2 peak; sterol pattern changes | Full GC profile; sterols |
| Fish oil | Raises EPA; changes the DPA pattern | DHA/EPA ratio falls below the algal range | GC profile against the EPA limit |
| DHA concentrate | Keeps the DHA figure; changes the rest of the profile | DHA passes, minor acids do not fit | Full profile; source traceability |
| Oxidised oil | Fresh oil blended to hit PV or FFA | p-Anisidine value and TOTOX stay high | PV, p-AV, FFA and TOTOX |
| Water | Raises moisture and hydrolysis | Moisture above 0.1%; FFA rising | Karl Fischer; FFA titration |
Colour is the weakest signal. A pale yellow to golden oil covers a wide range, and a blend can be matched to it. The stronger signals are the linoleic acid level, the DHA/EPA ratio, the sterol pattern and the oxidation pair. A certificate that reports appearance and DHA but not the full profile has not tested the substitution that matters most.
How to write identity into the specification
- “Algal DHA oil from the named strain; DHA 35.0–45.0% by GC; EPA ≤3.0%; DPA reported.”
- “Full fatty-acid profile reported with the chromatogram; GC setup and basis stated.”
- “Free fatty acid ≤0.50%; peroxide value ≤5.0 meq O₂/kg; moisture ≤0.1%.”
- “No added carrier oil; antioxidants declared if present.”
- “Sterol profile available on request; source statement and fish-free statement on file.”
- “Lot code, manufacture date and pack on the certificate and the retained sample.”
Five questions for the supplier
- Which algal strain and process produced this lot, and is that on the source statement?
- Can you provide the full GC-FID profile and chromatogram, not only the DHA percentage?
- What are the EPA and DPA figures from the same run, and what is the DHA/EPA ratio?
- What are the peroxide, p-anisidine, free fatty acid and moisture results for this lot, with test dates?
- If identity is contested, will you re-test the retained sample jointly?
Five direct answers make an identity file; one DHA percentage does not. The product hub holds the catalog specification; the COA page places each figure on the certificate; the powder page covers the carrier-based form; the methods section explains the GC work; the quality page describes the retained sample.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation