01 COA & batch testing

What the COA for algal DHA oil actually contains

Technical document 01 · Reviewed 2026-11-20 · Algal DHA Oil

On this page
  1. How to read the sheet
  2. What the DHA percentage is a percentage of
  3. Release limit versus batch result
  4. What moves between batches
  5. When an outside test earns its fee
  6. What to compare between suppliers

An algal DHA oil certificate reports the DHA content of the oil by gas chromatography, the free fatty acid and peroxide values that describe its condition, and the moisture, heavy-metal and microbiological limits for the lot. The catalog specification is DHA 35.0–45.0% by GC with EPA ≤3.0%, free fatty acid ≤0.50%, peroxide value ≤5.0 meq O₂/kg and moisture ≤0.1%. The certificate confirms one lot against those limits; the specification is the gate, not the measurement.

In one line

A DHA figure is only half the certificate: the GC profile fixes what the oil is, and free fatty acid, peroxide value and moisture say how well it has been kept.

How to read the sheet

A certificate is readable only when each line carries the parameter, the method and the limit. On an oil the release decision is made across three groups: the fatty-acid composition, the damage markers and the contaminants. A sheet that lists only the DHA percentage has left the other two groups out.

Release tests for algal DHA oil
ParameterMethodRelease limit
AppearanceVisualClear to slightly hazy oil
DHA (C22:6)GC-FID of methyl esters; peak against a DHA standard35.0–45.0%
EPA (C20:5)GC-FID, same run≤3.0%
Free fatty acidTitration as oleic acid≤0.50%
Peroxide valueTitrimetric; AOCS Cd 8b-90 or ISO 3960≤5.0 meq O₂/kg
MoistureKarl Fischer≤0.1%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPour plate and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Appearance is a weak limit but a useful early signal: a clear, pale yellow to golden oil can still be oxidised, and a hazy oil can be cold rather than damaged. The lot code, the manufacture date and the expiry date belong on the same sheet. An analysis without a lot code cannot be tied to the bottle or drum in front of you.

What the DHA percentage is a percentage of

The DHA figure is a mass fraction of the oil, produced by transesterifying the triglycerides to methyl esters and quantifying the C22:6 peak. Two GC setups can give different numbers from the same oil. An internal-standard calibration reports grams of DHA per 100 g of oil; an area-normalised run reports the composition of the fatty-acid fraction. The certificate should say which one it used, and whether the figure is on the oil as sold or on a dried basis.

The usual convention on a supplement oil is the fatty-acid content after methylation, expressed on the oil as sold. That is not the same as the triglyceride content, because the glycerol backbone is removed in the analysis and is not part of the reported mass. A certificate that mixes the two conventions is not comparable with one that does not, even when both print “DHA 40%”.

DHA is one fatty acid, not a synonym for omega-3. Algal oil is DHA-dominant with a small EPA fraction and a measurable DPA fraction, so a certificate that reports only “total omega-3” has not stated the DHA content that the label and the specification use. CAS 6217-54-5 identifies DHA as a substance; it does not identify the oil, its source or its concentration.

Release limit versus batch result

A limit is the boundary for release. A result is what the laboratory measured. The two belong in separate columns, with the method beside them. A result column that repeats the range is the gate copied out, not evidence that a measurement was made.

The result side of the certificate
TestRelease limitWhat the result must show
DHA35.0–45.0%A measured percentage, with the GC setup and standard named
EPA≤3.0%A measured percentage from the same run
Free fatty acid≤0.50%A measured percentage, expressed as oleic acid
Peroxide value≤5.0 meq O₂/kgA measured value, with the method and the test date
Moisture≤0.1%A measured percentage by Karl Fischer

The three damage markers answer different questions. Free fatty acid measures hydrolysis, the splitting of the triglyceride that moisture and heat accelerate. Peroxide value measures hydroperoxides, the first products of oxidation, and it can fall again as those hydroperoxides decompose. p-Anisidine value measures the aldehydes that follow, so it rises later and stays; it is not in the catalog specification for this oil, but it can be agreed as an additional line when oxidation is the question. Reading peroxide value alone can make an advanced sample look fresher than it is.

What moves between batches

Fermentation moves the fatty-acid profile: strain, carbon source, harvest time and the refining sequence all shift the DHA and EPA figures. A lot at the bottom of the 35.0–45.0% range is inside the specification, not a defect, but a run of lots at the same edge is a trend worth asking about. Refining also moves colour and the minor components; deodorisation reduces volatile odour compounds and can strip tocopherols, which leaves the oil with less protection after packing.

Peroxide value, free fatty acid and moisture move after the oil leaves the reactor. A warm hold, a wet drum, an open headspace or a long transit can raise all three without any change in the DHA figure. The lot that arrives is not necessarily the lot that was released, which is why the certificate's test date and the pack's seal both matter.

Retained samples turn single results into a trend. Compared with a limit, a result says pass or fail; compared with the previous five lots, it says which way the process and the handling are going.

When an outside test earns its fee

An outside laboratory earns its place for a new source, a first regulated-market shipment, a disputed identity or a fish-free claim that the file must support. The useful panel is not a repeat of the certificate: a full GC-FID profile with DHA, EPA and DPA, the sterol pattern, peroxide and p-anisidine values, free fatty acid, moisture, ICP-MS for the metal panel and a plate count with absence tests.

Two details decide what the report is worth. A “not detected” line needs a limit of quantification, otherwise it describes the method rather than the sample. And the sample tested should be the sample retained, with the lot code on the report, so a contested result can be re-tested rather than argued about.

What to compare between suppliers

Compare six lines: the algal source and strain, the DHA result with the GC setup, the EPA and DPA figures from the same run, the oxidation pair with test dates, free fatty acid and moisture, and the pack and lot traceability. Two quotations that agree on DHA and differ on the other five are not describing the same oil.

The catalog specification sits on the algal DHA oil product page. The spray-dried form is a different product with a carrier and its own certificate, covered on the algal DHA powder page. The GC and wet-chemistry methods are described in the methods section, and the release and retention workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation