06 Identity & adulteration

How we prove a pepsin lot is the named enzyme

Technical document 06 · Reviewed 2026-11-19 · Pepsin

On this page
  1. The four identity layers
  2. The ratio is not a purity figure
  3. X-ray diffraction: what it cannot tell you
  4. What adulteration looks like
  5. Specification lines that can be tested
  6. Five questions for the supplier

A pepsin lot is the named enzyme when four lines agree: the document names the species, tissue and CAS number; the activity assay gives the declared ratio under a named method; the protein pattern shows a band of the expected size; and the lot code matches the pack, the certificate and the retained sample. No single line carries the proof. The activity figure is the easiest to produce and the easiest to imitate.

In one line

Identity is the ratio plus the assay behind it, a protein band of the right size and a lot code that matches the pack.

The four identity layers

A certificate can name the right material and still fail to prove it. The layers below are separate questions, and each one needs its own evidence. A supplier who answers only the first has described the paperwork, not the powder.

Four layers of pepsin identity
LayerQuestionTestWhat it proves
DocumentIs the source named?Species, tissue, CAS 9001-75-6, EC 3.4.23.1Paperwork only
ActivityDoes it digest protein at acid pH?Haemoglobin assay with stated conditionsA functional acid protease
ProteinIs the protein the expected one?Gel electrophoresis, specific activity, infrared spectrumThe protein, not just an activity
TraceIs this the tested lot?Lot code on pack, COA and retained sampleConnection to the delivery

The functional assay is the strongest single check because an inactive or substituted protein usually fails it. It is not sufficient on its own: another acid protease can pass an activity assay at pH 2, and a diluted powder can be adjusted to the declared ratio. The protein and the document close those gaps.

The ratio is not a purity figure

The 1:10,000 designation states that one gram digests 10,000 grams of coagulated egg albumin under the conditions of the method. It is a digestive-power ratio, and it says nothing about how much of the powder is pepsin. A preparation can reach 1:10,000 by concentrating the enzyme or by diluting a stronger concentrate on a carrier; the ratio is the same and the powder is not.

The haemoglobin assay is the other axis. It measures the release of acid-soluble products at a stated pH, temperature and time, and it becomes a unit only after the calculation is defined. The FCC unit, the Anson unit and the 1:10,000 ratio are three different statements, and none of them converts into another without the method that produced it. The COA page sets out how each is reported.

pH is part of the identity, not only the assay. Pepsin is active in acid and loses activity as the pH rises toward neutral; an assay run at the wrong pH measures a different enzyme preparation. Ask for the pH, the substrate and the temperature beside the number, and compare only results produced the same way.

X-ray diffraction: what it cannot tell you

X-ray diffraction is a solid-state method for crystalline materials. A crystalline salt gives sharp reflections that act as a fingerprint; the commercial pepsin powder is amorphous, so its pattern is a broad halo rather than a set of peaks. That means XRD is not an identity test for the enzyme. A certificate that reports “XRD conforms” for pepsin has not shown the protein.

The method still has a use. It can detect a crystalline carrier or adulterant, such as a sugar or a salt, and it can show that a sample described as crystalline is not. Those are useful negative checks. They do not replace the activity assay, the infrared spectrum or the protein pattern, and they should not be sold as identity evidence for the enzyme itself.

For a disputed lot, ask for the actual pattern and the reference rather than a conformity statement. Then ask what the reference was: a pepsin standard, a carrier, or nothing that matches the sample.

What adulteration looks like

Failure signatures and the test that reveals each
FailureSignatureTest
Dilution with carrierRatio met, protein per gram lowPaired activity and protein; specific activity
Heat-damaged lotNormal protein, low activityActivity against protein; infrared spectrum
Another acid proteasePlausible acid activity, different behaviourpH profile, protein pattern, pepstatin inhibition
Species substitutionActivity similar, source differentSpecies-specific immunoassay; protein pattern
Moisture pickupLoss on drying high; as-is activity lowLoss on drying beside the activity
Lot mix-upCodes do not meet across documentsLot code on pack, COA and sample

Dilution and heat damage pull the numbers in opposite directions, so the pair of figures separates them: a low ratio with normal protein points to inactivation, while a normal ratio with low protein points to a carrier. Substitution is harder. A pH-activity profile and a protein pattern are the practical screens, and a species-specific test is the direct check when the label names the species.

Specification lines that can be tested

  • “Pepsin from gastric mucosa, species and tissue stated; CAS 9001-75-6; EC 3.4.23.1.”
  • “Activity 1:10,000 by the named ratio or haemoglobin method, with pH, temperature and time.”
  • “Unit result if reported, with the unit definition.”
  • “Protein or specific activity, where identity against dilution is to be checked.”
  • “Identification by activity assay and infrared spectrum against a reference.”
  • “Loss on drying ≤8.0%; particle size ≥95% through 40 mesh; carrier named.”
  • “Heavy metals and microbiology as listed; storage statement.”

Write the activity as a specification with a method appendix, and keep the appendix under change control. A new haemoglobin lot or a re-made standard can move the comparison even when the wording on the certificate stays the same.

Five questions for the supplier

  1. Which species and tissue is this lot from, and where is that stated?
  2. What does 1:10,000 mean in your method, and what are the substrate, pH, temperature and time?
  3. What are the activity, protein and specific activity of this lot?
  4. What test shows that the powder is not a dilution, and will you run it?
  5. Which document carries the lot code that matches the pack?

Written answers to all five give a buyer something to audit. The catalog values are on the pepsin product page; the release tests are on the COA page; the assay conditions are described in the method notes; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation