02 Grade & ratio

Pepsin 1:10,000 or 1:3,000: choosing a grade

Technical document 02 · Reviewed 2026-11-19 · Pepsin

On this page
  1. No purity figure exists for an enzyme
  2. The grades in the catalog
  3. Mesh, flow and dust
  4. Working out the charge weight
  5. Turning the choice into specification lines
  6. When a dilution works against you

Grade choice for pepsin comes down to three variables: the ratio, the material that carries it and the particle form. The catalog standard is a 1:10,000 powder at 40 mesh; a granulated version is available on request, and a lower ratio such as 1:3,000 is a different specification. Each choice changes the mass needed for the same digestive power and what else enters the formula.

In one line

A pepsin grade is a ratio plus the material that carries it, so the mass needed for the same digestive power moves when the ratio moves.

No purity figure exists for an enzyme

An enzyme preparation is not a pure compound. It contains the enzyme, other proteins and whatever carrier was used to set the final activity. No single percentage describes that mixture, so the trade describes a pepsin grade by its ratio, its source and its form instead.

The ratio is the oldest of those descriptors. 1:10,000 means one gram digests 10,000 grams of coagulated egg albumin under the conditions of the method; 1:3,000 means 3,000 grams. The figures can be compared with each other because they come from the same kind of measurement, but they are not units and they do not convert into a haemoglobin result.

What the grade controls
ChoiceWhat it setsWhere it bites
RatioDigestive power per gramCharge weight and overage
CarrierWhat the enzyme is diluted onIngredient list, moisture pick-up, flow
MeshParticle size and surfaceMixing, wetting, airborne dust
FormPowder or granuleDust control, dispersion time, process loss
SourceSpecies and tissue of originIdentity file and market documents

The grades in the catalog

The catalog standard is the 1:10,000 powder. Granulation is offered on request, and a dilution to an agreed ratio is quoted as a separate specification rather than a packing option.

Catalog options and the formula consequence
OptionActivityFormConsequence for the formula
Standard powder1:10,00040 mesh powderLightest charge for a given power; made for dry blends
Granules1:10,000GranulatedLess dust; slower wetting; check process loss
DilutionAgreed in the specificationPowderHeavier charge; more carrier on the label

None of these figures can be compared across unit systems. The 1:10,000 ratio and an Anson or FCC unit describe different assays, as the COA page sets out. A certificate that prints one number without its method has not told the buyer which of them was measured.

Mesh, flow and dust

At ≥95% through 40 mesh, roughly 420 µm, the powder mixes evenly into a dry blend and wets quickly in water, giving the acidic solution the specification describes. The same fines that speed wetting stay airborne. Enzyme dust is a respiratory sensitiser, so extraction, closed transfer and a suitable mask belong in the handling plan, and the safety data sheet carries the hazard language.

Granules trade wetting speed for a cleaner room. They are the better choice where operators handle kilos a day; they are the wrong choice for a stick pack that must disperse quickly. Granulation adds water and heat, so the activity of the granule has to be measured after the step rather than calculated from the powder that went in.

Pepsin is hygroscopic. A 40 mesh powder left open in a humid room picks up water, and the loss on drying climbs toward the 8.0% limit. Keep the pouch sealed and the drum liner closed, and let a cold pack equilibrate before opening it.

Working out the charge weight

Begin with the digestive power the batch needs. If both grades are measured by the same ratio method, the mass scales inversely with the ratio: 1 kg of 1:3,000 carries the same power as 0.3 kg of 1:10,000, so replacing 1 kg of the 1:10,000 grade with the 1:3,000 grade takes 3.33 kg. The arithmetic holds only while the method is the same; confirm that before using the factor.

If the specification is written in units rather than a ratio, dose from the units and set the ratio aside. A ratio cannot be converted into Anson or FCC units without the method that produced both figures, and a supplier who offers a factor should show the underlying data.

Weighing decides the rest. The 1:10,000 powder is weighed in small charges, and a pilot batch may struggle with the precision. A dilution buys precision with carrier, which then has to be declared and dispersion-tested like any other ingredient.

Turning the choice into specification lines

  • “Pepsin from gastric mucosa, species stated; CAS 9001-75-6; EC 3.4.23.1.”
  • “Activity 1:10,000 by the named ratio or haemoglobin method, with the conditions.”
  • “Unit result if one is reported, with the unit definition.”
  • “Protein or specific activity, where the buyer uses it to detect dilution.”
  • “Loss on drying ≤8.0%; particle size ≥95% through 40 mesh.”
  • “Carrier identity; heavy metals; microbiology as listed.”
  • “Form: powder or granulated; storage statement and labelled basis.”

A line that cannot be measured at goods-in does not belong in a purchase specification. Keep the method appendix under change control, because a new haemoglobin lot or a re-made standard changes the comparison even when the specification wording stays the same. The specification glossary entry covers the vocabulary.

When a dilution works against you

A blend already near its carrier ceiling gains nothing from more diluent. A formula that has no room for more water gains nothing from a carrier that binds it. A short ingredient list gains nothing from a line that exists only to make the scoop heavier.

Scale adds another case. A dilution that solves a pilot weighing problem becomes an extra material to test, declare and store once the batch is large enough to weigh the concentrate directly. Choose the grade for the batch you will run most often, not for the trial.

Catalog values are on the pepsin product page; the release tests are on the COA page; how each form holds activity is on the stability page; pack sizes and lead time are on the MOQ page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.