Reading an invertase COA: activity, unit and release limits
An invertase certificate is short, and one line carries most of the practical value: the activity. That line is a rate per gram measured on sucrose at a stated pH and temperature, so it is comparable only when the unit definition and the assay conditions are printed beside it. The remaining rows cover appearance, moisture, particle size, metals and microbiology. Read the document as a test report, not as a label.
The activity is a rate, not a concentration: without the unit definition, the sucrose substrate and the assay conditions, the number cannot be reproduced.
The certificate as a test report
A release certificate is useful when every row can be checked. Each line needs the test, the method and the limit; the measured result belongs in its own column.
| Test | Method | Release limit |
|---|---|---|
| Appearance | Visual inspection | White to light tan, free-flowing powder |
| Activity | Sucrose hydrolysis; unit definition stated | ≥100,000 U/g |
| Identification | Activity assay conform; EC 3.2.1.26 and source named | Conforms |
| Loss on drying | Gravimetric | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
CAS 9001-57-4 names the enzyme, but it does not identify the preparation. The certificate should also name the production organism and the carrier, because the same activity can be reached by different routes. A specification that stops at CAS and U/g has described a category, not a lot.
What the activity number means
The assay starts with sucrose in buffer. The sample is diluted into the linear range, incubated for a fixed time at a fixed temperature, and the reaction is stopped. Glucose is then measured, usually with glucose oxidase/peroxidase, by a reducing-sugar method, or by HPLC. One molecule of sucrose yields one molecule of glucose and one of fructose, so the glucose result is also the sucrose result. Activity is calculated as micromoles of glucose per minute per gram of powder as sold.
Two published definitions show why the wording matters. One widely used definition sets a unit as the hydrolysis of 1.0 micromole of sucrose per minute at pH 4.5 and 55 °C. The JECFA monograph defines its unit on reducing sugar expressed as invert sugar per minute, and the FCC uses an INVU with its own factor. These are separate definitions; a figure in one is not a figure in another without the method.
| Item | Required detail | Why it matters |
|---|---|---|
| Unit basis | U per gram of powder as sold | A dry-basis or protein-basis figure is a different number |
| Substrate | Sucrose, grade and concentration | The rate depends on substrate concentration |
| pH | The assay pH | Activity falls outside the working window |
| Temperature | The assay temperature | Temperature changes the rate; the assay temperature must be stated |
| Time and stopping | Incubation time and stop reagent | Short or long incubations leave the linear range |
| Detection | Glucose oxidase/peroxidase, reducing sugar or HPLC | Different detectors calibrate differently |
| Calculation | µmol glucose/min/g; dilution and blank | The formula is part of the method |
| Moisture basis | As-is or dry-solids basis | Water changes the number without changing the enzyme |
The commercial basis is per gram of powder as sold. A carrier dilution lowers the units per gram without changing the enzyme; a dry-solids figure can look higher because it removes water.
Release limit versus batch result
≥100,000 U/g is a floor, not a target. Two lots at 104,000 and 210,000 U/g would both pass, yet a process that consumes part of the activity would respond to them differently. The limit is the gate; the measured value is what the formulator has to work with.
| Test | Release limit | What the lot result shows |
|---|---|---|
| Activity | ≥100,000 U/g | Measured U/g, with method, unit definition and RSD |
| Loss on drying | ≤5.0% | A measured percentage |
| Heavy metals | Per element | One figure per element, in mg/kg |
| Microbiology | Counts and absence | The plate count plus the absence result |
| Particle size | ≥95% through 80 mesh | The percentage that passed the 80 mesh sieve |
Ask for the method reference, the release date, and whether the value refers to release or to the end of the shelf life.
Where the variation comes from
Fermentation is the first source of spread. Strain, medium, sucrose feed, aeration and harvest time change how much enzyme the cells make. Recovery and concentration decide how much of that activity reaches the powder. Standardisation with a food-grade carrier then fixes the units per gram, and drying and milling can lose activity through heat.
Water and heat continue to move the figure after release. A powder stored in a humid room picks up moisture, and the as-is activity falls even when the protein is intact. Colour is not a release test: a darker tan can follow a longer dry while the activity remains in specification. Read the batch record before rejecting a lot on appearance.
Method drift is harder to see. A new substrate lot, a recalibrated glucose standard or a different incubation bath can make two U/g results incomparable even when the paperwork looks identical.
When to order an outside assay
An outside assay earns its place for a new source, an initial shipment to a regulated market, a disputed result, or a label statement that rests on the activity figure. The scope can remain modest: the named activity method on a retained sample, protein or specific activity, moisture, the metal panel, microbiology, and a protein pattern compared with a reference preparation.
The laboratory has to use the same substrate, pH, temperature and calculation as the specification; otherwise the exercise compares methods, not powders. A report in SU/g is not a second opinion on a U/g result unless the SU definition is the same. The sample and the report must carry the same lot code, and the report should state the laboratory's accreditation for each test.
A side-by-side comparison
Put six lines side by side: the unit and its definition, the assay pH and temperature, the measured activity, the protein figure or specific activity, the moisture and the mesh, and the source organism with its carrier. Agreement on U/g is not agreement on the preparation; the other five lines decide that, and a trial will expose the gap before the quotation does.
Traceability comes next. The lot code on the paper must match the pouch and the retained sample, and the certificate should name the source organism. If the code does not match the pack, the certificate is valid for some other delivery.
The catalog values sit on the invertase product page. The checks that separate a real preparation from a diluted or substituted one are on the identity page; the quality page sets out how a lot is released; the assay families are compared in the methods library; the terms are defined in the COA glossary entry.