01 COA & batch testing

What the hemicellulase COA contains, and what the unit leaves out

Technical document 01 · Reviewed 2026-11-20 · Hemicellulase

On this page
  1. Auditing the certificate row by row
  2. The substrate, the calibrant and the basis
  3. Limit, result and the result column
  4. What changes from lot to lot
  5. When an outside test earns its place
  6. Comparing two quotations

The certificate for a hemicellulase lot reports appearance, identification by the activity assay, activity in U/g, loss on drying, particle size, the heavy-metal panel and microbiology. The activity row is the one that needs a definition behind it: hemicellulase is a class of enzymes, so a U/g figure describes the rate measured on one named substrate, at one pH and temperature, against one calibrant. The limits in the first table are the catalog specification; the batch COA is what confirms a particular pack.

In one line

A hemicellulase certificate is a statement about one assay: the U/g figure, the substrate, the pH, the temperature and the calibrant are one fact, and none of them survives alone.

Auditing the certificate row by row

A certificate can be audited line by line when each row carries what was measured, the method behind the number and the limit the lot was released against. An enzyme row needs a fourth element, the assay conditions, because the same powder reads differently at another pH, temperature or substrate lot. Identification and activity are one measurement here: the assay on the named hemicellulose substrate is also the identity test. The class-level CAS number 9025-56-3 registers the name, not the composition.

Release specification · hemicellulase powder
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan, free-flowing powder
IdentificationActivity assay on the named hemicellulose substrateConforms to the reference
Hemicellulase activityReducing-sugar assay on the named substrate; unit definition stated≥50,000 U/g
Loss on dryingGravimetric≤8.0%
Particle sizeSieve analysis≥95% through 80 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The substrate, the calibrant and the basis

An activity unit is a rate, not a mass: the usual definition is the amount of preparation that releases one micromole of reducing sugar equivalents per minute under the stated conditions. The substrate comes first, because hemicellulose is a family of polysaccharides — xylan and arabinoxylan, xyloglucan, mannan and galactomannan, mixed-linkage β-glucan — and a substrate prepared from plant material has its own composition. A xylan-rich substrate and a mannan-rich substrate do not give the same number for the same powder.

The calibrant comes second. Reducing-sugar detection is read against a standard curve, and the standard may be xylose, glucose or mannose. Their response factors differ, so two laboratories can report 50,000 U/g for the same powder and each be correct inside its own definition. The mass basis comes third: a result per gram as received includes moisture, a result per gram of dry solids excludes it, and at the 8.0% limit the two differ by about 8.7%. State the basis and print the loss on drying beside the activity. The conditions complete the definition, and a preparation measured at its acidic optimum can read far lower at the neutral pH of a feed mash or a plant-protein extract.

Limit, result and the result column

The release limit is the acceptance boundary; the batch result is what the laboratory measured, in its own column, with the method and the date. A result column filled with the catalog range is a copy of the gate, not a result. Activity is one-sided, so a lot at 52,000 U/g passes and a lot at 85,000 U/g also passes; the result shows the headroom a process step has to consume.

What belongs in the result column
ParameterRelease limitResult column
Hemicellulase activity≥50,000 U/g by the named methodA measured U/g figure, with substrate, calibrant and basis
Side activitiesAgreed limits, one per activityA measured figure for each declared activity
Loss on drying≤8.0%A measured percentage
Particle size≥95% through 80 meshThe measured percentage through the sieve
Heavy metals and microbiologyPer element; counts and absenceA figure per element; the count and the absence statement

Side activities need their own columns. A hemicellulase preparation carries xylanase, and usually mannanase, arabinase, xylosidase and a little cellulase; when those are agreed, each is measured by its own method and released against its own limit. None is added to the hemicellulase figure or inferred from it. Ask for the activity guaranteed at the end of the retest period as well as the release figure, because heat and time remove units between the two dates.

What changes from lot to lot

The fermentation sets the starting point: strain, medium, induction and harvest shift the balance of activities in the broth, and recovery and standardisation decide how much of that balance reaches the powder. Because the name covers a mixture, a change of strain can move the side-activity profile while the declared U/g still passes.

The substrate lot moves the assay, so the laboratory should record the substrate source and lot with the result. Drying and milling move the activity as well: a wetter powder reads lower per gram, and a milling step that generates heat destroys activity before the sieve is reached. The 80 mesh figure is finishing, so it can change with the mill or the sieve alone. Colour is the least quantitative line and often the most revealing: a darker tan can follow a hotter dry or a longer hold while the activity still passes. A trend across lots says more than one result near an edge, and the lot code on the certificate should match the pouch, the drum and the retained sample.

When an outside test earns its place

An independent test is worth ordering for a new source, a first shipment into a regulated market, a use that depends on one declared side activity, or a disputed result. The useful panel repeats the activity on the retained sample by the buyer's method and by the method named in the specification, then adds protein, loss on drying, heavy metals by ICP-MS, microbiology and the side activities that matter for the process.

Name those activities rather than asking for “hemicellulase”: xylanase, mannanase, arabinase and cellulase, each with its own substrate. Add a protease screen when the powder will sit in a liquid blend, because a protease in the preparation digests the enzyme it travels with. Ask for the detection limit on every screen; a “not detected” line without a limit describes the method, not the sample. The sample tested should be the retained sample, and the report should identify the lot.

Comparing two quotations

Put six lines side by side: the declared name with source organism and CAS number; the unit definition with substrate, pH, temperature and calibrant; the activity result and its basis; the side-activity profile with methods; loss on drying, particle size and carrier; and the lot code with the manufacturer. Two quotations that agree on U/g but differ on substrate or profile are not describing the same preparation.

The catalog specification sits on the hemicellulase product page. The layers that prove a lot is the named preparation are on the identity page; the unit question against a single-enzyme product is on the xylanase page; the assay vocabulary is in the methods library; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation