02.1 Glucose oxidase vs catalase

Glucose oxidase vs catalase: two oxidoreductases, two units

Technical document 02.1 · Reviewed 2026-11-20 · Glucose Oxidase

On this page
  1. Two reactions, one after the other
  2. Why 10,000 U/g means two different things
  3. How each number is produced
  4. What a blend can and cannot do
  5. What to write into the specification
  6. Choosing one, the other, or both

Glucose oxidase and catalase are both oxidoreductases, but they act on different molecules. Glucose oxidase oxidises β-D-glucose and oxygen to D-glucono-1,5-lactone and hydrogen peroxide; catalase decomposes hydrogen peroxide to water and oxygen. Their units come from different assays and cannot be converted, so a blend is two specifications, not one stronger ingredient.

In one line

Glucose oxidase consumes glucose and oxygen to make hydrogen peroxide; catalase consumes that peroxide, so their units describe different reactions and do not convert.

Two reactions, one after the other

Glucose oxidase is a flavoprotein: its FAD cofactor takes electrons from β-D-glucose and passes them to oxygen, producing hydrogen peroxide. The lactone product hydrolyses to gluconic acid in water, which is why some methods report glucose consumed and others report acid formed. Catalase is a heme enzyme: it splits hydrogen peroxide into water and oxygen, two molecules of peroxide giving two of water and one of oxygen.

The two reactions and their enzymes
EnzymeSubstrateProductsEC numberCAS number
Glucose oxidaseβ-D-glucose and oxygenD-glucono-1,5-lactone (to gluconic acid) and hydrogen peroxide1.1.3.49001-37-0
CatalaseHydrogen peroxideWater and oxygen1.11.1.69001-05-2

The two reactions connect: glucose oxidase makes the substrate that catalase removes. Neither enzyme performs the other's reaction. Glucose oxidase does not remove peroxide, and catalase does not oxidise glucose. The connection is why the two are sometimes used together, and why their assays interfere when both are present.

Why 10,000 U/g means two different things

One glucose oxidase unit is the amount that oxidises one micromole of β-D-glucose per minute in the peroxidase-coupled assay; the specification can be agreed at pH 5.1 and 25 °C. One catalase unit clears one micromole of hydrogen peroxide per minute at pH 7.0 and 25 °C; the decrease is read at 240 nm at a stated starting concentration. Both units equal 16.67 nkat as a rate, but the mole refers to a different substrate and the assays use different conditions.

The conditions are not decoration. A glucose oxidase result at pH 6.0 is not the result at pH 5.1, and a catalase result at a higher starting peroxide concentration can be lower because the enzyme is inhibited by its own substrate. A “total oxidoreductase units” figure that adds the two has no method behind it. Ten thousand units of glucose oxidase per gram and ten thousand units of catalase per gram are two unrelated quantities.

Most enzyme units are rates on a named substrate; the same rule applies to a protease on a protein substrate or a lysozyme on a bacterial suspension. The analytical methods library explains why the assay defines the unit.

How each number is produced

The glucose oxidase method is indirect. The enzyme generates hydrogen peroxide, peroxidase uses it to oxidise a chromogen such as ABTS or 4-aminoantipyrine, and the laboratory follows the increase in absorbance at the wavelength of that chromogen. The coupling is convenient and it adds failure modes: catalase in the sample consumes the peroxide before the chromogen sees it, reducing agents and coloured components interfere, and turbidity adds apparent absorbance. The glucose concentration must be saturating, and the reading must allow for mutarotation of the β-anomer.

The catalase assay is direct: buffer at pH 7.0, a known starting peroxide concentration, and the decrease in absorbance at 240 nm as the peroxide is consumed. Read only the linear part of the curve; at a high starting concentration the enzyme can be inhibited and the plot bends. A blank corrects for the powder's own absorbance.

ORAC and DPPH are chemical radical-scavenging assays, not enzyme assays. Neither result can be converted into units of glucose oxidase or catalase, and neither says whether the enzyme in the powder is active. The quality page describes the release workflow.

What a blend can and cannot do

A blend of the two is a formulation. In the dry powder the reaction waits for water; once dissolved, glucose oxidase generates peroxide and catalase removes it, and the ratio between the two activities sets how much peroxide remains. If the target is glucose conversion with little peroxide left, catalase can be part of the design; if the target is peroxide, catalase is a side activity that has to be limited. The application decides, not the unit number.

The two enzymes also have different pH optima, near 5.5 for glucose oxidase and near 7.0 for catalase, so one matrix pH cannot be the optimum of both. Measure each activity on the finished blend rather than calculating it from the weigh-up; the two proteins can decline at different rates through blending and storage. A certificate that gives one combined enzyme activity has specified neither component.

A protease in the same blend can break down either enzyme, and an overage calculated on the blend total will not protect the component that is losing activity fastest.

What to write into the specification

  • “Glucose oxidase (EC 1.1.3.4), CAS 9001-37-0; catalase (EC 1.11.1.6), CAS 9001-05-2; each source named.”
  • “Glucose oxidase ≥10,000 U/g by the glucose/peroxidase assay, with pH, temperature, glucose concentration and detection system.”
  • “Catalase ≥10,000 U/g by the UV hydrogen-peroxide assay at 240 nm, with pH, temperature and starting peroxide concentration.”
  • “Each activity assayed separately on the blend; the ratio declared.”
  • “Carrier, stabiliser and granulation aid declared; no combined activity figure.”
  • “Loss on drying, heavy metals, microbiology and particle size as listed.”
  • “Storage condition and retest period stated for each enzyme in the blend.”

A specification written this way can be released against. A single “enzyme activity” line cannot.

Choosing one, the other, or both

Choose glucose oxidase when the target is glucose or oxygen and the hydrogen peroxide it produces is acceptable, useful or removed downstream. Choose catalase when the target is hydrogen peroxide and the glucose reaction is irrelevant. If both reactions are wanted, name both enzymes and measure each; a U/g figure from one is not evidence for the other.

Do not convert one enzyme's units into the other's, and do not offer a chemical antioxidant result as proof of either activity. The glucose oxidase product page and the catalase product page carry the catalog values; the glucose oxidase grades page covers the single-enzyme choice; the methods library and the quality page cover the assays and release.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation