02 Grade comparison

Glucose oxidase grades: activity, carrier and source

Technical document 02 · Reviewed 2026-11-20 · Glucose Oxidase

On this page
  1. What a grade actually fixes
  2. The catalog grade and its versions
  3. Powder, granule and solution behaviour
  4. Dose arithmetic before the label
  5. What to write into the specification
  6. When a version is the wrong choice

Glucose oxidase is bought as a number of units per gram, and that number means little without the assay behind it. The catalog version is a yellow-tan powder at ≥10,000 U/g by the glucose/peroxidase method, milled to pass 80 mesh. Granulation, the production source and the physical form all alter the powder that arrives, even when the label still says glucose oxidase.

In one line

A glucose oxidase grade is an activity plus a carrier and a source; the U/g figure and its assay conditions decide what the powder can do.

What a grade actually fixes

Three decisions hide behind the word grade: how much activity is in each gram, what else is in the powder, and which organism made the enzyme. The first is the number on the certificate; the other two explain why two powders with the same U/g can behave differently in a blend or a solution.

Activity is not the same as purity. A preparation can be diluted with a carrier and keep its specific activity if the carrier is not protein, while a lot with plenty of inactive protein can carry a normal U/g figure and a low specific activity. The protein figure and the assay conditions are the second half of the description.

The production organism matters because the protein, its pH profile and its response to heat are not identical across sources. A specification that names only “glucose oxidase” leaves the source open, and a change of source is a change of material, not a new lot of the same thing.

The catalog grade and its versions

Catalog powder and granulated glucose oxidase
AttributeCatalog powderGranulated (on request)
Activity≥10,000 U/gSet per order; the binder adds mass
Particle size≥95% through 80 meshCoarser, set by the granulation
Flow and dustFree-flowing, some finesBetter flow, less dust
Added materialNone declaredBinder or granulation aid
Typical useRapid dispersion and dry blendsHigh-speed filling and dust control

The table is about physical handling, not about a stronger or weaker enzyme. Granulation changes the particle build and adds a binder. If a custom grade is diluted on a carrier, the units in each gram fall and the carrier must appear in the allergen and ingredient review. Neither change is a way to make the enzyme work better; they are ways to make it easier to weigh or blend.

Powder, granule and solution behaviour

At 80 mesh the powder is fine enough to disperse quickly, and fine enough to dust. Yellow to light tan is the catalog appearance; the colour can move with the drying step and the carrier without a change in activity. In water the powder gives a clear to slightly turbid solution. The fine fraction carries static and can cling to the weighing boat, so a containment step is sensible.

Granulation trades fineness for flow. A granule is easier to feed into a high-speed blender and generates less airborne dust, but it dissolves more slowly and brings a binder into the formula. If the powder is diluted on a carrier, the bulk volume per unit of activity rises; a fixed fill weight then delivers fewer units unless the weight is raised. The carrier also brings moisture, particle size and a label name.

The catalog moisture limit is ≤8.0%. It is a release limit for activity retention, not an invitation to store the powder in a humid room.

Dose arithmetic before the label

Work from the units the process needs, then convert to powder. At 10,000 U/g, a 250 mg scoop carries 2,500 U, a 600 mg scoop carries 6,000 U, and 2 g carries 20,000 U. At 5,000 U/g the same 2,500 U needs 500 mg. These are conversions, not recommended doses.

For a food process the target is normally expressed per kilogram of substrate or per litre of liquid, and the trial establishes it. For a dry blend, the target is units per batch. In both cases the activity method must match the method used to set the target; a number from a different pH or chromogen is not a drop-in.

An overage belongs to the stability file. If the enzyme loses activity over the declared period, the formulator may add extra at the start so the end-of-life figure holds. That decision changes the weigh-up and the label, and it cannot rescue a grade that is physically wrong for the line.

What to write into the specification

  • “Glucose oxidase, EC 1.1.3.4, CAS 9001-37-0; production organism stated.”
  • “Activity ≥10,000 U/g by the glucose/peroxidase method; pH, temperature, glucose concentration and detection system stated.”
  • “Protein or specific activity reported, with the protein method.”
  • “Loss on drying ≤8.0%; ≥95% through 80 mesh.”
  • “Carrier or granulation aid disclosed; say so when none is present.”
  • “Heavy metals and microbiology per the catalog; storage condition and retest period.”
  • “Source, carrier and physical form under change control.”

A specification that omits the method or the source is a label, not a purchase specification. The product page has the catalog values; the COA page shows the release lines; the level-four comparison separates the units from catalase; the stability page covers the loss that justifies an overage.

When a version is the wrong choice

Choose the fine catalog powder when the process needs rapid dissolution and can control dust. Choose a granule when flow and dust are the limiting problems and a slower dissolve is acceptable.

None of these is right if the customer's specification names a different mesh, a different source or a carrier-free material. Matching U/g does not make two grades interchangeable, and a change of source or carrier needs a new specification and a label check, not a note on the purchase order.

The catalog entry and the quality page are the place to start that change discussion.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation