02 Grade comparison

200,000 U/g or a dilution: choosing an alkaline protease grade

Technical document 02 · Reviewed 2026-11-19 · Alkaline Protease

On this page
  1. What a grade actually fixes
  2. Three formats side by side
  3. Particle size, flow and dust
  4. The arithmetic when you switch grades
  5. What changes in the specification
  6. When a dilution is the wrong purchase

The catalog grade is a free-flowing 40 mesh powder standardised to ≥200,000 U/g, with a lower-activity dilution offered on request. A dilution is the same enzyme spread over more carrier, so the activity per gram of powder falls while the activity per kilogram of blend stays where the formulator put it. Choosing a grade is therefore choosing what one gram of powder does, how much carrier arrives with the enzyme and whether the powder can be weighed accurately at the rate the formula needs.

In one line

A 200,000 U/g grade and its dilution carry the same enzyme per unit of activity; what changes is the mass you weigh, the carrier you add and the dust the line sees.

What a grade actually fixes

A grade is not a purity statement. It fixes four things at once: the activity per gram, the amount and identity of the carrier used to reach it, the particle size and flow of the powder, and the unit definition behind the number. Two powders at 200,000 U/g from different suppliers can differ on the last three, and a switch between them is a formulation change rather than a like-for-like purchase.

The catalog offers the standard grade, a lower-activity dilution on request and a granulated form on request. All three start from the same concentrate; the differences are what has been added and what has been done to the particle.

Three formats side by side

Alkaline protease formats in the catalog
FormatWhat it isWhen it fitsWhat to check
Powder, 40 mesh, ≥200,000 U/gConcentrate standardised with carrier to the catalog activityMost blends, where the addition rate is smallUnit definition, carrier identity, dust
Lower-activity dilutionThe same concentrate extended with more carrierWhere the addition rate must be large enough to weigh and disperse evenlyCarrier load in the finished unit, activity after the process
GranulatedAgglomerated particles, usually coarser and less dustyLines where dust control or flow is the limiting factorGranule size, dispersion time, heat added during granulation

Particle size, flow and dust

Forty mesh is about 420 µm: the specification ≥95% through 40 mesh means the powder passes a 420 µm sieve almost completely, not that every particle is that size. The fines fraction below about 100 µm is what becomes airborne when a bag is opened, and it is the fraction that matters for dust exposure and for segregation in a blend.

Enzyme powders are respiratory sensitisers, and the safety data sheet describes the dust controls: local extraction at the weighing point, closed transfer where the line allows it, and the specified respiratory protection. A granulated grade reduces the airborne fraction but does not remove the hazard, and it can change the dispersion time in a drink mix. The water solubility is another physical line: the powder dissolves to a clear to slightly hazy solution, and a granulated grade may need longer mixing to reach the same appearance.

The particle-size glossary entry explains how the mesh figure is measured and why two certificates can quote the same mesh and behave differently.

The arithmetic when you switch grades

Activity per unit of finished product is what the formula fixes; the mass of powder is the variable. A blend that needs 500,000 U per 5 g stick takes 2.5 g of a 200,000 U/g powder, or 10 g of a 50,000 U/g dilution, which will not fit in the same 5 g stick. The dilution is the right purchase when the addition rate is already a few percent of the blend and the concentrate would be too small to weigh; it is the wrong purchase when the carrier would crowd out the other ingredients.

Two more numbers belong in the calculation. The first is process loss: granulation, drying and tableting each remove part of the activity, and an overage has to be based on a measured loss for that process rather than on a general rule. The second is the basis of the declaration: activity at release and activity at the end of shelf life are different promises, and a blend built to the release figure can fall below its label claim before the end of the stated life.

Worked in units rather than grams, the arithmetic is exact. One kilogram at 200,000 U/g carries 200 million units; two kilograms at 100,000 U/g carry the same total. That identity holds only when both figures come from the same assay, which is why the unit definition is part of the grade and not a footnote to it.

What changes in the specification

A specification that can be checked at goods-in carries the activity as “not less than” with the unit and method reference, the carrier and its amount, the particle size, loss on drying, the pH of a 1% solution, the production organism and strain, the activity basis, and the storage statement. Switching grade changes at least three of those lines even when the activity per kilogram of blend is unchanged.

Re-qualification after a switch is short but not optional: assay the new grade, run it through the real process step, assay the blend or the finished unit, and repeat the stability arm for the pack. The COA page shows which lines the release document has to carry, and the stability page covers what the process does to the activity.

When a dilution is the wrong purchase

A dilution is a poor choice when the finished unit is small, when the carrier is already close to its limit in the formula, or when the label states an activity per unit and the extra carrier would have to be declared without adding anything the customer asked for. It is also the wrong answer to a stability problem: spreading the same enzyme over more carrier does not protect it from heat or moisture, and the larger mass can pick up more water in an open weigh room.

What a dilution does buy is weighing accuracy and dispersion. If the concentrate is dosed at a fraction of a percent, the scale and the mixer may not distribute it evenly, and a 20,000 U/g grade can be the difference between a uniform blend and a hot spot. That decision belongs with the process engineer, not with the purchasing desk.

The catalog figures are on the alkaline protease product page, the difference between this enzyme and the neutral one is set out on the alkaline versus neutral page, and the pack sizes and order quantities are on the MOQ page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation