01 COA & batch testing

What the COA for alkaline protease actually contains

Technical document 01 · Reviewed 2026-11-19 · Alkaline Protease

On this page
  1. The certificate as a test report
  2. What one U measures, and what sets the figure
  3. Release limit versus batch result
  4. What moves between batches
  5. When an outside laboratory earns its fee
  6. Six lines to compare between suppliers

The certificate for an alkaline protease lot reports appearance, activity in U/g, the pH of a 1% solution, loss on drying, particle size, the heavy-metal panel and microbiology. The activity row is the only line that describes the enzyme, and the figure means little unless the certificate sets the unit definition, the substrate and the pH and temperature beside it. The ranges below are the catalog specification for the ≥200,000 U/g powder from Bacillus licheniformis; the batch COA is the document that confirms one drum of alkaline protease.

In one line

An alkaline protease figure in U/g is a rate read at alkaline pH on a named protein substrate, so the certificate has to carry the unit, the substrate and the assay conditions beside the number.

The certificate as a test report

A certificate can be audited only when every row carries the parameter, the method and the limit the lot was released against. For an enzyme the activity row needs a fourth element, the assay conditions, because the same powder reads differently at pH 8 and at pH 11.

Release specification · alkaline protease powder from Bacillus licheniformis
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan, free-flowing powder
Alkaline protease activityCasein hydrolysis, Folin-Ciocalteu detection, tyrosine standard, U/g≥200,000 U/g
pH (1% solution)Potentiometry8.0–10.0
Loss on dryingGravimetric≤8.0%
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤10,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Loss on drying sets the basis of the activity figure, since water dilutes the powder without changing what the protein can do. Particle size sets the dust a 40 mesh powder still carries, and the safety data sheet has to describe it.

What one U measures, and what sets the figure

Alkaline protease activity is quoted in U/g, and the unit exists only as the assay that defines it. A common definition takes one unit as the amount of enzyme that liberates 1 µg of tyrosine equivalent per minute from casein at pH 10.0 and 40 °C, read with Folin-Ciocalteu reagent against a tyrosine standard. Other houses use haemoglobin, 37 °C, a 30-minute incubation, or micromoles instead of micrograms. Each is a legitimate scale; none converts without running both assays on the same sample.

The activity row, read line by line
ElementWhat it has to sayWhy it moves the figure
UnitU per gram of powder as sold, with the tyrosine basis statedµg and µmol of tyrosine differ by a factor of about 180
SubstrateCasein, haemoglobin or a synthetic peptideDifferent proteins present different cleavage sites
pHUsually 10.0, sometimes 8.5 or 11.0This enzyme is built for alkaline pH; the rate falls away from its optimum
Temperature and time40 °C for 10 or 30 minutes, or 37 °CThe rate climbs with heat until the protein unfolds
DetectionFolin-Ciocalteu colour at about 660 nm, or a trinitrobenzene sulphonate methodTwo chemistries read different products of the hydrolysis
BasisAs-is, or corrected to dry solidsMoisture moves the number at unchanged activity

At ≥200,000 U/g, one kilogram carries at least 200 million units. That is a rate per gram of preparation, not a purity figure, and the protein behind it is only a fraction of the gram. Protein and specific activity are the second number, set out on the identity page.

Release limit versus batch result

Activity is a one-sided limit: a lot at 205,000 U/g and a lot at 260,000 U/g both pass ≥200,000 U/g. The result column, not the limit, tells a formulator how much headroom the powder carries into a granulation or a drying step that will consume part of it.

A result column that repeats the specification is not a result, and the word “conforms” is a conclusion the reader should be able to reach from the numbers. Ask for the measured value, the method reference and the release date on the same page. Because activity falls in storage, the certificate should also state the storage condition assumed and the activity guaranteed at the end of shelf life; a drum bought six months after release is bought at the lower figure.

What moves between batches

Fermentation sets the starting point: strain, medium, induction and harvest shift how much protease the broth holds and how much of it is the alkaline enzyme. Recovery and ultrafiltration decide what reaches the concentrate, and standardisation with a carrier sets the final activity per gram. A supplier holding ≥200,000 U/g is choosing where in the concentrate to land, so the spread between lots is a process decision as much as a biological one.

Moisture, pH and particle size move with drying and milling and move the activity figure with them: a wetter powder reads lower per gram at constant true activity, and a milling step that generates heat can destroy activity before the sieve is reached. The pH of a 1% solution is a useful process signal: a shift within 8.0–10.0 can follow a change in fermentation or in the standardisation salts. Colour is the least quantitative signal and often the most revealing: a darker tan can follow a hotter dry while the assay still passes.

Watch the method as closely as the number: if substrate grade or assay pH changes between lots, two certificates that both say U/g describe different measurements.

When an outside laboratory earns its fee

An independent test is worth ordering for a new source, a first shipment into a regulated market, or a disputed result. The panel is narrow: activity by the buyer’s own method on a retained sample, protein, loss on drying, heavy metals by ICP-MS, microbiology, and a protein pattern by gel electrophoresis.

The referee has to run the same substrate and the same pH as the specification, or the comparison measures methods rather than powder. Ask for the detection limit on each metal; a “not detected” line without a limit describes the method, not the sample. The sample tested should be the sample retained, with the lot code written on both.

Six lines to compare between suppliers

Put six lines side by side: unit definition, substrate and conditions, activity result with its method, protein and specific activity, moisture and particle size, and organism, strain and carrier. Two quotations that agree on U/g but differ on the other five are not describing the same preparation, and the gap surfaces at the first process trial.

Traceability is the second layer. The lot code should match on the certificate, the pack and the retained sample, and the certificate should name the production organism and strain, because the source is part of a food enzyme’s identity.

The catalog figures sit on the alkaline protease product page, the grade options are compared on the grades page, the release workflow behind the certificate is described on the quality page, and the vocabulary is in the COA glossary entry.