What the COA for L-valine actually contains
The certificate for an L-valine lot reports appearance, identification by infrared and ninhydrin, assay by titration on the dried basis, specific rotation, loss on drying, residue on ignition, pH, particle size, heavy metals and microbiology. Each line carries the test, the method and the release range. These values are the catalog specification; the batch COA confirms a particular lot, and no single figure proves the L form.
The titration measures how much amino acid is in the drum; the rotation says it is the L form, and the dried basis says what the percentage measures.
The certificate as a test report
A useful certificate answers three questions per line: what was measured, by which method, and against which limit.
| Parameter | Method | Release limit |
|---|---|---|
| Identification | Infrared and ninhydrin reaction | Conforms |
| Assay (dried basis) | Titration | 98.5–101.5% |
| Specific rotation | Polarimetry, dried basis | +26.6° to +28.8° |
| Loss on drying | Gravimetric | ≤0.5% |
| Residue on ignition | Gravimetric | ≤0.1% |
| pH (5% solution) | Potentiometry | 5.5–6.5 |
| Particle size | Sieve analysis | ≥95% through 40 mesh |
| Heavy metals | ICP-MS or ICP-OES | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
Two lines matter most: the assay says how much amino acid is present, the rotation says which configuration. The rest describe water, powder and contaminants.
What the assay measures, and on what basis
The assay titrates the amino acid's acid and base groups and returns the mass of amino acid after correction to the dried material. The 98.5–101.5% window is a release range, not a purity grade: a result above 100% is possible when the titrant and the drying correction carry a small positive bias.
The dried basis makes the figure comparable. Loss on drying is capped at 0.5%, so a lot at the water limit reads slightly higher after correction than as-is. The certificate should show both. Water is not a solvent residue, but it is mass that is not valine.
Titration is not specific. Leucine and isoleucine each carry one amino and one carboxyl group, so they consume titrant in the same proportion and can lift a titre without being valine. HPLC separates the branched-chain amino acids and shows whether the main peak is the named one. Where both are reported, ask which method releases the lot.
Specific rotation belongs on the same dried basis. The reading depends on solvent, concentration, path length and temperature, so conditions belong on the certificate. The window +26.6° to +28.8° is consistent with L-valine; it does not prove the drum is only valine. pH is a solution check: 5.5–6.5 at 5%, near the isoelectric point, with a shift pointing to residual acid or alkali, another salt or a blend.
Release limit versus batch result
The release limit is the gate; the batch result is what the laboratory measured. They belong in separate columns with method and basis. A result column filled with the range is a copy of the gate, not a measurement.
| Column | What belongs there | What it does not mean |
|---|---|---|
| Release limit | The catalog or agreed acceptance range | A measurement of this lot |
| Batch result | The value obtained on the lot by the named method | A guarantee for the next lot |
| Method | Titration, polarimetry, gravimetry, sieving, ICP-MS or ICP-OES, plate count | That the method is specific to valine |
| Basis | Dried basis, as-is or solution concentration | A detail that can be left to the reader |
| Conclusion | Pass or fail against the limit | A substitute for the raw result |
Appearance is descriptive; pH and water are narrow checks; the contaminant and micro panels have their own limits. “Conforms” works for identification only when the tests are named.
What moves between batches
Assay moves with crystallisation yield, drying and the titration standard. Water moves with the dryer and the pack: an open pouch gains moisture, and the next dried-basis assay hides it. pH moves with residual acid or alkali. Particle size moves with mill and sieve, which is why mesh belongs in the specification.
Rotation is the line to watch. A drift toward the bottom of the window with a flat assay can mean a small D fraction, a change in polarimeter conditions or a different raw-material source. One edge result is not a rejection; a sequence is a supplier question.
Colour and flow are less quantitative and often more revealing. A grey or yellow tint can point to hot drying, iron or a dirty mill while the assay passes. Ask for the batch record and deviation history, and compare the retained sample with the drum.
When to order an outside test
Order an independent test for a new source, a first shipment into a regulated market, a rotation that does not fit, a suspected DL mixture or a blend sold as free valine. A targeted panel is enough: rotation with conditions, chiral HPLC for D-valine, assay by titration and HPLC, infrared identification, ICP-MS and a plate count.
Ask for detection and quantification limits. “D-valine not detected” without a limit describes the method, not the sample. Give the referee the retained sample and keep the chain intact; the sample tested should be the sample retained.
What to compare between suppliers
Compare six lines: name, form and CAS; assay method and basis; rotation and conditions; water, residue and pH; particle size; contaminants. Two quotes that match on assay but differ on rotation or water are not the same powder.
| Line | What to compare | Why it matters |
|---|---|---|
| Identity | L-valine, CAS 72-18-4, formula C5H11NO2 | A blend or a DL mixture can carry the same name |
| Assay | Titration, 98.5–101.5% on the dried basis, with HPLC if offered | Method and basis set what the percentage means |
| Rotation | +26.6° to +28.8° on the dried basis, with solvent and temperature | Configuration is not visible in the assay |
| Water and residue | Loss on drying ≤0.5%; residue on ignition ≤0.1% | Water and ash are mass that is not valine |
| Physical | ≥95% through 40 mesh; milled or granulated on request | Flow and blend uniformity depend on particle size |
| Contaminants | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg; micro panel | Release limits are part of the specification |
The lot code should match on certificate, pack and retained sample, and the certificate should name the manufacturer and route. A correct certificate can still belong to another drum.
The catalog specification is on the L-valine product page; forms are compared on the grade page, identity tests are on the identity page, and the release workflow is on the quality page. The separation is in the HPLC method note, and assay is defined in the glossary.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation