01 COA & batch testing

What the COA for L-valine actually contains

Technical document 01 · Reviewed 2026-11-19 · L-Valine

On this page
  1. The certificate as a test report
  2. What the assay measures, and on what basis
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for an L-valine lot reports appearance, identification by infrared and ninhydrin, assay by titration on the dried basis, specific rotation, loss on drying, residue on ignition, pH, particle size, heavy metals and microbiology. Each line carries the test, the method and the release range. These values are the catalog specification; the batch COA confirms a particular lot, and no single figure proves the L form.

In one line

The titration measures how much amino acid is in the drum; the rotation says it is the L form, and the dried basis says what the percentage measures.

The certificate as a test report

A useful certificate answers three questions per line: what was measured, by which method, and against which limit.

Identity, assay and physical limits · L-valine
ParameterMethodRelease limit
IdentificationInfrared and ninhydrin reactionConforms
Assay (dried basis)Titration98.5–101.5%
Specific rotationPolarimetry, dried basis+26.6° to +28.8°
Loss on dryingGravimetric≤0.5%
Residue on ignitionGravimetric≤0.1%
pH (5% solution)Potentiometry5.5–6.5
Particle sizeSieve analysis≥95% through 40 mesh
Heavy metalsICP-MS or ICP-OESPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Two lines matter most: the assay says how much amino acid is present, the rotation says which configuration. The rest describe water, powder and contaminants.

What the assay measures, and on what basis

The assay titrates the amino acid's acid and base groups and returns the mass of amino acid after correction to the dried material. The 98.5–101.5% window is a release range, not a purity grade: a result above 100% is possible when the titrant and the drying correction carry a small positive bias.

The dried basis makes the figure comparable. Loss on drying is capped at 0.5%, so a lot at the water limit reads slightly higher after correction than as-is. The certificate should show both. Water is not a solvent residue, but it is mass that is not valine.

Titration is not specific. Leucine and isoleucine each carry one amino and one carboxyl group, so they consume titrant in the same proportion and can lift a titre without being valine. HPLC separates the branched-chain amino acids and shows whether the main peak is the named one. Where both are reported, ask which method releases the lot.

Specific rotation belongs on the same dried basis. The reading depends on solvent, concentration, path length and temperature, so conditions belong on the certificate. The window +26.6° to +28.8° is consistent with L-valine; it does not prove the drum is only valine. pH is a solution check: 5.5–6.5 at 5%, near the isoelectric point, with a shift pointing to residual acid or alkali, another salt or a blend.

Release limit versus batch result

The release limit is the gate; the batch result is what the laboratory measured. They belong in separate columns with method and basis. A result column filled with the range is a copy of the gate, not a measurement.

Reading the limit and result columns on an L-valine COA
ColumnWhat belongs thereWhat it does not mean
Release limitThe catalog or agreed acceptance rangeA measurement of this lot
Batch resultThe value obtained on the lot by the named methodA guarantee for the next lot
MethodTitration, polarimetry, gravimetry, sieving, ICP-MS or ICP-OES, plate countThat the method is specific to valine
BasisDried basis, as-is or solution concentrationA detail that can be left to the reader
ConclusionPass or fail against the limitA substitute for the raw result

Appearance is descriptive; pH and water are narrow checks; the contaminant and micro panels have their own limits. “Conforms” works for identification only when the tests are named.

What moves between batches

Assay moves with crystallisation yield, drying and the titration standard. Water moves with the dryer and the pack: an open pouch gains moisture, and the next dried-basis assay hides it. pH moves with residual acid or alkali. Particle size moves with mill and sieve, which is why mesh belongs in the specification.

Rotation is the line to watch. A drift toward the bottom of the window with a flat assay can mean a small D fraction, a change in polarimeter conditions or a different raw-material source. One edge result is not a rejection; a sequence is a supplier question.

Colour and flow are less quantitative and often more revealing. A grey or yellow tint can point to hot drying, iron or a dirty mill while the assay passes. Ask for the batch record and deviation history, and compare the retained sample with the drum.

When to order an outside test

Order an independent test for a new source, a first shipment into a regulated market, a rotation that does not fit, a suspected DL mixture or a blend sold as free valine. A targeted panel is enough: rotation with conditions, chiral HPLC for D-valine, assay by titration and HPLC, infrared identification, ICP-MS and a plate count.

Ask for detection and quantification limits. “D-valine not detected” without a limit describes the method, not the sample. Give the referee the retained sample and keep the chain intact; the sample tested should be the sample retained.

What to compare between suppliers

Compare six lines: name, form and CAS; assay method and basis; rotation and conditions; water, residue and pH; particle size; contaminants. Two quotes that match on assay but differ on rotation or water are not the same powder.

Six lines for a supplier comparison · L-valine
LineWhat to compareWhy it matters
IdentityL-valine, CAS 72-18-4, formula C5H11NO2A blend or a DL mixture can carry the same name
AssayTitration, 98.5–101.5% on the dried basis, with HPLC if offeredMethod and basis set what the percentage means
Rotation+26.6° to +28.8° on the dried basis, with solvent and temperatureConfiguration is not visible in the assay
Water and residueLoss on drying ≤0.5%; residue on ignition ≤0.1%Water and ash are mass that is not valine
Physical≥95% through 40 mesh; milled or granulated on requestFlow and blend uniformity depend on particle size
ContaminantsPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg; micro panelRelease limits are part of the specification

The lot code should match on certificate, pack and retained sample, and the certificate should name the manufacturer and route. A correct certificate can still belong to another drum.

The catalog specification is on the L-valine product page; forms are compared on the grade page, identity tests are on the identity page, and the release workflow is on the quality page. The separation is in the HPLC method note, and assay is defined in the glossary.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation