01 COA & batch testing

Reading a GABA certificate: identity, assay and moisture

Technical document 01 · Reviewed 2026-11-19 · GABA

On this page
  1. The certificate, line by line
  2. The assay needs a detection method
  3. Release limit against batch result
  4. What moves from lot to lot
  5. When an outside test is worth ordering
  6. Six lines to compare between suppliers

The certificate for a GABA lot reports appearance, identification by infrared spectrum and HPLC retention, assay by HPLC, loss on drying, the pH of a 1% solution, the heavy-metal panel, microbiology and particle size. Every line should carry the method and the release limit, with the measured result in a column of its own. The ranges in the first table are the catalog specification; the batch certificate is the document that confirms a particular pack.

In one line

A GABA certificate is complete when the assay names its HPLC detection, the loss on drying sits beside it, and the identity rests on a spectrum as well as a retention time.

The certificate, line by line

A certificate is auditable when every row answers three questions: what was measured, by which method, and against which limit. GABA has no chiral centre and no counter-ion, so there is no rotation line and no salt ratio to read. The identity has to come from the spectrum and the chromatogram, and those are the rows to open first.

A row that says only “conforms” states a conclusion; the spectrum and the retention time are the evidence behind it.

Identity, assay and purity limits · GABA
ParameterMethodRelease limit
AppearanceVisualWhite crystalline powder
IdentificationIR spectroscopy and HPLC retentionSpectrum and retention conform to the reference
AssayHPLC with amine derivatisation or ninhydrin detection99.0–101.0%
Loss on dryingGravimetric≤0.5%
pH (1% solution)Potentiometric6.5–7.5
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 40 mesh

The pH row is not a formality: a 1% solution of this zwitterion sits at 6.5–7.5, and a figure outside that range points to an acid residue, a different salt or a basic carrier.

The assay needs a detection method

GABA has no strong ultraviolet chromophore, so an HPLC method has to make the molecule visible. The usual routes are pre-column derivatisation of the amine, ion-exchange separation with post-column ninhydrin, or a detector that does not depend on absorbance. The certificate should name the reagent, the column and the detection mode. An assay figure without them cannot be repeated in a second laboratory and cannot be compared with a figure from another supplier.

The basis is the other half of the number. The catalog range is 99.0–101.0%, and the certificate should say whether the figure is on the dried basis or on the powder as received. The loss on drying is ≤0.5%, so the gap between the two bases is small: a lot at 99.0% as-is with 0.4% moisture reads 99.40% on the dried basis (99.0 ÷ 0.996). Small, but it is exactly the gap that decides a release against a 99.0% floor.

A range that reaches 101.0% also asks about the standard: which reference material was used, and whether the result is corrected for its purity.

Release limit against batch result

The release limit is the boundary for the lot; the batch result is what the laboratory measured. Both belong on the certificate, in separate columns, with the method named beside them. A result column filled with the specification range is not a result; it is a copy of the gate.

What the result column should show
ParameterRelease limitResult column
Assay99.0–101.0%A measured percentage with its basis, standard and detection
Loss on drying≤0.5%A measured percentage
pH (1% solution)6.5–7.5A measured pH with the concentration
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceA count and an absence statement for the lot
Particle size≥95% through 40 meshThe measured percentage through the sieve

“Passes specification” is a conclusion the reader should be able to reach without taking it on trust: four figures for the heavy metals, because a total hides which element is present, and a count plus an absence statement with its detection limit for microbiology.

What moves from lot to lot

GABA is made by enzymatic decarboxylation of L-glutamate or by chemical synthesis, and the route leaves a different impurity fingerprint. Residual glutamate, a salt load from a neutralisation step and a residual solvent belong to one route and not necessarily to the other. None of them has to fail the assay, which is why the related-substance profile is worth asking for.

Drying moves the loss on drying; milling and sieving move the particle-size result. A fine hygroscopic powder also carries static, so a sieve figure can shift with the weather in the packing room and not only with the mill. Colour and caking move with moisture, and neither is an identity failure.

A trend across lots says more than one result near an edge: an assay drifting towards 99.0%, a pH edging down, a new small peak in front of the main one. The lot code on the certificate should match the pouch, the drum and the retained sample; where it does not, the document describes a different pack.

When an outside test is worth ordering

Order an independent test for a new source, a first shipment into a regulated market, a disputed result, or a lot presented as GABA when a neighbouring amino acid is possible. The useful panel is not a copy of the certificate: an infrared spectrum against the reference, an HPLC run that resolves GABA from beta-alanine and alanine, elemental carbon and nitrogen, loss on drying, ICP-MS for the four elements and the microbiological count.

A chloride or ash figure is worth adding when the source is new, because the catalog carries no line for either and a salt cut would otherwise stay invisible. Ask the laboratory to report its detection limit for each screen: a “not detected” line without a limit is evidence about the method, not about the sample.

Keep the chain of custody. The sample tested should be the retained sample, and the report should identify the lot. When a result is contested, give the referee the retained sample, the supplier's certificate and the specification, and ask for the tests that separate the materials rather than a repeat of the same assay.

Six lines to compare between suppliers

Put six lines side by side: the name and CAS number, the assay with its method and basis, the identity evidence, the moisture and pH, the contaminant and microbiological results, and the pack with its lot code. Two quotations that both say 99% but differ on the method or the basis are not describing the same powder.

The second layer is traceability: who manufactured the lot, by which route, with which drying and milling steps, and which specification revision applies. The GABA product page carries the catalog specification. The identity page sets out the evidence that separates this amino acid from its nearest neighbours; the comparison with beta-alanine covers the substitution that is easiest to miss; the HPLC method note describes the separation, and the quality page describes the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation