The gamma-oryzanol grade is an assay, a profile and a powder
γ-Oryzanol is supplied as one catalog grade: a ≥95.0% powder, with a granulated form available on request. What a buyer actually receives is decided by three lines that move independently — the assay, the ferulate profile and the physical form. The profile matters because the material is a mixture: two lots can both pass at 95% and still carry different shares of cycloartenyl, 24-methylenecycloartanyl, campesteryl and β-sitosteryl ferulates.
The grade is decided by three lines that move independently: the assay, the ferulate profile and the form of the powder.
Why a mixture has grades at all
A single molecule can be graded by assay alone, because the percentage describes one substance. A mixture cannot. The total can be held at 95% while the composition moves underneath it, and the composition is what the formulator actually works with. A lot rich in cycloartenyl ferulate and a lot rich in the 24-methylene analogue are both γ-oryzanol, and they are not the same powder.
Rice bran is the source. The rice variety, the harvest and the refining step that separates the oil all shift the proportions, so a profile agreed against one source may not hold when the next campaign arrives. That is a property of an agricultural extract rather than a defect, and it is why a profile clause belongs in the specification.
The form is the third axis. A fine powder and a granulated powder carry the same chemistry and behave differently in a blender, a capsule filler and a tablet press.
The three axes side by side
The first table is what a buyer can write into a purchase order. The second is what changes when the same powder is granulated.
| Axis | What it decides | How it is written |
|---|---|---|
| Assay | How much ferulate ester is present | ≥95.0% by HPLC, with the method, standard and basis |
| Profile | Which esters, in what proportion | Named peaks, a minimum share for the principal ester and a free-acid limit |
| Form | How the powder flows and dusts | Powder, or granulated on request with the particle profile agreed |
| Attribute | Catalog powder | Granulated (on request) |
|---|---|---|
| Appearance | White to off-white, free-flowing powder | White to off-white, granular |
| Assay | ≥95.0% by HPLC | ≥95.0% by HPLC |
| Melting point | 135–140 °C | 135–140 °C |
| Moisture | ≤1.0% | ≤1.0% |
| Handling | Dusts; needs containment at weigh-up | Lower dust; better flow |
| Typical use | Capsules, tablets, small blends | High-speed blending and filling |
Granulation changes the particle form, not the chemistry. The assay, melting point and moisture lines stay as they are, and the particle profile is agreed separately. It is a specification change with a lead-time consequence, not a packing choice.
Solubility and handling
The material is insoluble in water and soluble in ethanol and in warm oils. In practice the powder is handled dry, dissolved in the oil phase of an emulsion, or suspended in a blend; it is not a candidate for a clear aqueous drink. A formulator who needs a transparent beverage has to look at a different ingredient, not a different grade.
The powder is fine and it dusts. Static and dust are handling issues rather than quality failures, but they affect weigh-up accuracy and operator exposure, and a granulated form reduces both. In a humid room the powder can cake, which is a moisture problem and not a melting problem: the melting point is far above ambient.
At 135–140 °C the melting point is well above any normal capsule or tablet process. A hot-melt extrusion can pass that temperature, and the material would then melt and resolidify as a fused mass. A process that hot needs a different specification, not a higher assay.
Dose arithmetic and the label
The label declares γ-oryzanol, and the weigh-up is in grams of powder. The two numbers meet through the assay: 100 mg of a 95.0% powder delivers 95 mg of γ-oryzanol, and a 500 mg capsule fill at the same assay carries 475 mg.
The ferulate figure is a separate calculation. The principal ester is about 32% ferulic acid by mass (194.18 ÷ 602.9), so 100 mg of a 95% powder holds roughly 31 mg of ferulic acid equivalent after hydrolysis. That figure is useful in a formulation discussion and when sources are compared, but it is not the declared ingredient. A label that names ferulic acid needs the free acid.
State the basis with the dose. A 95.0% result on the dried basis is not 95.0% of the powder as weighed, and a formula built on the dried figure overstates the active mass by about one percentage point at the moisture limit. The conversion is arithmetic, not a recommendation, and it belongs in the batch record rather than only in the marketing file.
What to write into the specification
- “γ-Oryzanol, CAS 11042-64-1, a mixture of ferulate esters with cycloartenyl ferulate (C₄₀H₅₈O₄) as the principal member.”
- “Assay ≥95.0% by HPLC; name the integrated peaks, the reference standard and the basis.”
- “Ferulate profile: the principal ester share and a free ferulic acid limit, agreed for the source.”
- “Melting point 135–140 °C; moisture ≤1.0% by Karl Fischer.”
- “Heavy metals Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg; microbiology as listed.”
- “Source: rice bran, with the origin statement travelling with the lot.”
- “Form: powder, or granulated on request with the particle profile agreed separately.”
We supply the 95% powder and the granulated form. A diluted or blended material is a different specification with a different label, and it should not be ordered by changing the assay figure on the same purchase order.
When another material is the right choice
If the formula calls for free ferulic acid, the ester is the wrong input, and the oryzanol and ferulic acid comparison sets out the conversion and the label consequence. If the formula calls for the long-chain alcohols rather than a ferulate ester, policosanol is that mixture, specified on a different basis. If the formula needs a clear aqueous solution, neither material delivers it without a solubiliser.
Specification values are on the product hub; the certificate layout is on the COA page; the hydrolysis risk is set out on the stability page; the profile tests are on the identity page; release practice is on the quality page.
In this document
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation