What the COA for wheat protein peptides actually contains
A wheat peptide COA has to answer three questions at once: how much protein the lot contains, how much of it is peptide, and whether the wheat allergen is declared. The protein and peptide figures depend on the Kjeldahl factor, the basis and the HPLC cut-off, so none of them is portable without its method. The certificate should also show moisture, ash, contaminants, microbiology and the mesh.
A wheat peptide certificate only makes sense when the Kjeldahl factor, the peptide method and the wheat/gluten statement are read together; the protein percentage alone does not describe the lot.
The certificate as a line-by-line report
The release lines below are the catalogue specification. A lot certificate repeats them with measured results and names the method used for each one. A row that says only “conforms” cannot be compared with another supplier's certificate.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan powder |
| Protein | Kjeldahl; nitrogen factor stated | ≥80.0% |
| Peptide content | HPLC; method and cut-off stated | ≥70.0% |
| Moisture | Gravimetric | ≤7.0% |
| Ash | Gravimetric, furnace | ≤5.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g · yeast and mould ≤100 cfu/g · E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
Identification is a separate conclusion. “Protein and peptide profile conform” should be backed by a chromatogram. The source is wheat, and the gluten statement sits beside it; the protein percentage cannot prove either.
Protein, peptide and the basis behind them
Kjeldahl is a nitrogen method. The laboratory digests the powder, distils the ammonia and multiplies nitrogen by a factor. Wheat commonly uses 5.70; 6.25 is also seen. Same nitrogen, different answer: 80.0% at 5.70 becomes 87.7% at 6.25.
The basis is the other variable. The catalogue gives protein ≥80.0% and moisture ≤7.0% but does not state as-is or dry. At 7.0% moisture, 80.0% dry is 74.4% as-is. The certificate must print the basis and the factor, or the number cannot be compared.
Peptide is measured by HPLC and needs a definition: column, standards and cut-off. At the floors, 70.0 ÷ 80.0 = 0.875, so 87.5% of the protein is counted as peptide. The gap may be larger chains, free amino acids or non-protein nitrogen. A peptide result above the protein result means the methods disagree, not that the powder is better.
Gluten is a different question. It is a protein fraction of wheat, and the allergen declaration is not derived from the protein percentage. A lot can be 80% protein and still contain gluten peptides.
Release limit versus batch result
Release limits and results are different columns. The limit is the gate; the result is the measurement. A result column that repeats the specification has not reported a lot.
| Parameter | Release limit | Result column |
|---|---|---|
| Protein | ≥80.0% on the stated basis | The measured percentage, the nitrogen factor and the basis |
| Peptide content | ≥70.0% by HPLC | The measured percentage and the HPLC method |
| Moisture and ash | ≤7.0% and ≤5.0% | A measured percentage for each |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
| Particle size | ≥95% through 80 mesh | The measured percentage through the sieve |
| Wheat and gluten | Source declaration; gluten line where claimed | The source statement, and a gluten result in mg/kg if a claim is made |
The certificate should let a reader reconstruct the pass. Microbiology needs a count plus an absence statement; heavy metals need a figure per element; the wheat line needs a source statement. A gluten-free statement needs a method, a limit of quantification and the destination limit, not just the words.
What moves between lots
Wheat is a crop. Protein, gluten fraction and ash vary with class, variety, season and origin. Vital gluten and flour give different baselines, and colour and ash follow the raw material.
Hydrolysis is the next variable. Enzyme, dose, time and temperature set the peptide curve. A long hydrolysis raises free amino acids and can taste bitter or savoury; a short one leaves large peptides that can haze. Neutralised deamidation adds salt and ash.
Drying and milling set moisture, colour and mesh. A hot dryer can darken the powder; ash near 5.0% can taste salty or haze a drink. Colour inside off-white to light tan is not an identity failure, but a shift outside it deserves the batch record.
When an outside test earns its place
Order outside testing for a new source, a first regulated shipment, a gluten claim or a dispute. Ask for protein with factor and basis, peptide and distribution, amino acids, moisture, ash, ICP-MS, microbiology and a gluten method fit for hydrolysates.
Gluten testing is method-sensitive. R5 sandwich ELISA is the Codex-aligned screen for intact gluten; a hydrolysed protein can lose the epitopes it targets, so a validated hydrolysate method or a competitive format may be needed. Ask for extraction, standard and limit of quantification. “Not detected” without a limit says nothing about absence.
Wheat also carries Fusarium mycotoxins, especially deoxynivalenol. Ask for a DON result and the destination limit. Keep the tested sample as the retained sample and match the lot code.
Six lines to compare between suppliers
Six lines: source and gluten statement; protein factor and basis; peptide method; moisture, ash and mesh; contaminants and mycotoxins; traceability. A match on protein alone is not a match on material.
The catalogue specification sits on the wheat protein peptides product page. The tests that support the source and the peptide figures are on the identity page; the label consequences are on the compliance page. The analytical methods library explains the HPLC and Kjeldahl work, and the quality page describes the release workflow.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation