What the COA for corn protein peptides reports
A corn peptide certificate is read on two axes at once: how much nitrogen the powder carries, and how much of that nitrogen sits in short chains. The first is a Kjeldahl result with a stated factor and basis; the second is an HPLC distribution with a stated window. The table below gives the catalog limits that both results are released against, and the batch COA is what shows a specific lot meeting them.
Protein by Kjeldahl and peptide by HPLC answer different questions, so the certificate only means something when both methods, the moisture and the ash are reported beside the result.
Reading the certificate line by line
A certificate is a test report, not a badge. Each line should let a reviewer reconstruct the decision: the parameter, the method and the limit, in that order. When a line says only “conforms”, the reviewer has to take the conclusion on faith.
Corn peptides make that demand harder because the material is defined by a fraction, not by a single molecule. One row reports nitrogen; another reports the peptides inside a size window. They can both be correct and still describe different things.
| Parameter | Method | Release limit |
|---|---|---|
| Appearance | Visual | Off-white to light tan powder |
| Identification | Protein and peptide profile | Conforms to the reference |
| Protein | Kjeldahl nitrogen | ≥80.0% |
| Peptide content | HPLC peptide distribution | ≥70.0% |
| Ash | Gravimetric | ≤5.0% |
| Moisture | Loss on drying | ≤7.0% |
| Heavy metals | ICP-MS | Pb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg |
| Microbiology | Plate count and absence tests | APC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent |
| Particle size | Sieve analysis | ≥95% through 80 mesh |
Kjeldahl protein, the nitrogen factor and the as-is basis
Kjeldahl digestion converts nitrogen to ammonia and measures it; the protein figure is that nitrogen multiplied by a factor. The factor is a convention, not a measurement, and 6.25 is only the most common convention. If the factor is missing, the percentage cannot be reproduced.
The basis is a second convention. A result can be expressed on the powder as received or after subtracting moisture. The catalog says ≥80.0% and leaves the basis to the specification, so the specification has to choose one and keep it. An 80.0% as-is result at 6.0% moisture works out at about 85.1% dry basis: the same powder, two numbers.
Nitrogen is also carried by free amino acids, ammonia and other small molecules that are not peptides. A high protein figure is therefore a statement about nitrogen, not about chain length. That is why the certificate needs the peptide line as well.
Release limit versus batch result
Two columns are often conflated: the limit the lot must meet, and the value the laboratory found. The first is the specification; the second is the evidence. A result column that repeats the limit has told the reader nothing about the lot.
| Parameter | Release limit | Result column |
|---|---|---|
| Protein | ≥80.0% | A measured percentage, with the factor and the basis |
| Peptide content | ≥70.0% | A measured percentage, with the HPLC window and the chromatogram |
| Ash | ≤5.0% | A measured percentage |
| Moisture | ≤7.0% | A measured percentage |
| Heavy metals | Per element | A measured figure in mg/kg for each element |
| Microbiology | Counts and absence | The count and the absence statement for the lot |
Microbiology is a count plus an absence statement. Heavy metals are a figure for each element, not a total; a summed figure can hide the one element that fails. The peptide line needs the chromatogram and the integration window as well as the percentage, or the number cannot be compared across suppliers.
What moves between lots
Three process steps move the numbers. Hydrolysis sets the peptide distribution: enzyme, dose, temperature, pH and time all shift how far the protein is broken down. Neutralisation sets the ash, because the salt formed from alkali and acid stays in the powder. Drying and milling set moisture and mesh.
Appearance is a coarse check. The catalog range runs from off-white to light tan, and a shade within that range does not by itself indicate a problem. A clear darkening is worth a question about the drying hold or the decolourisation step, even when protein and peptide both pass.
Across lots, direction matters more than a single result. Peptide falling, ash rising or moisture climbing with the season are trends worth investigating before a limit is breached. The lot code should connect the certificate, the pack and the retained sample.
When an outside test earns its place
An outside laboratory is useful when the supplier's data is not enough: a new source, a first shipment to a regulated market, a label claim that depends on the peptide figure, or a disputed lot. The panel should target the decision, not repeat the whole certificate.
Ask for Kjeldahl with the factor, HPLC peptide distribution with the chromatogram, amino acid analysis, ash, moisture, ICP-MS and microbiology. Two additional checks answer source questions: the amino acid pattern (corn is low in lysine and tryptophan, soy is not) and a soy ELISA where a soy-free statement is needed. For corn, add GMO status and a mycotoxin panel as separate items.
Retain the sample that was tested and record the lot. If a result is challenged, the referee needs the retained sample and the specification, and a test that can separate corn from another source rather than a second run of the same protein method.
What to compare between suppliers
Compare suppliers on the things that change the powder, not only on the headline protein figure: the corn fraction and hydrolysis route; the nitrogen factor and basis; the peptide window; ash and moisture; contaminants and microbiology; pack and lot code. Two certificates can agree on protein and still describe different materials.
The catalog values are on the corn protein peptides product page. The identity page sets out the source tests, the grades page explains the peptide and mesh choices, the HPLC method note covers the separation, and the quality page describes release.
Related documents
Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.
Request a quotation