06 Identity & adulteration

How to prove a lot is chromium nicotinate

Technical document 06 · Reviewed 2026-11-19 · Chromium Nicotinate

On this page
  1. The four identity layers
  2. The chromium-to-ligand ratio
  3. Why XRD is not the identity test
  4. What adulteration looks like
  5. What to write into the specification
  6. Five questions for the supplier

A chromium nicotinate lot is the nicotinate complex when four lines agree: the chromium result sits in the 12.0–12.8% window, infrared shows the nicotinate ligand, HPLC gives the complex and the ligand on the same lot, and the powder is the trivalent grey-green complex rather than another chromium salt or a dyed dilution. The chromium figure alone cannot do it, because the picolinate complex has the same formula and almost the same chromium content; the ligand is the line that names the material.

In one line

Chromium proves the metal, infrared proves the ligand, and the chromium-to-nicotinate ratio proves the complex; no single line does all three.

The four identity layers

A certificate can name the right article and still fail to prove the powder. The four layers below are separate questions, and each needs its own evidence. A supplier who answers only the first has described the paperwork, not the material.

Four layers of chromium nicotinate identity
LayerQuestionEvidence
ArticleIs the material named?Specification, CAS 64452-96-6, lot certificate
MetalHow much chromium is present?Complexometric titration, 12.0–12.8%
LigandIs the ligand the nicotinate?Infrared spectrum, HPLC nicotinic acid
Ratio and disclosureIs it the complex, and is anything else present?Chromium-to-ligand ratio, carrier and dilution statement

A chromium result can pass while the ligand is wrong; an infrared match can pass while the lot is diluted. A dilution can still be a legitimate article, but only when the carrier and the ratio are declared.

The chromium-to-ligand ratio

The complex has three nicotinate ligands for each chromium atom. On a mass basis, chromium is 12.43% and the three ligands are about 87.6%, a chromium-to-ligand mass ratio of about 1 : 7.0. That arithmetic is the second identity check: a lot with a normal chromium figure and too little measured ligand points to a blend with another chromium source, and a lot with too much ligand points to unreacted nicotinic acid or a dilution.

The catalog reports identification by infrared and HPLC rather than a numeric ligand assay. That is enough to confirm identity; it is not enough to compute a ratio. If the ratio matters for a dispute, ask for the HPLC basis — free nicotinic acid or total nicotinic acid after the complex is released — and make sure the chromium and the ligand results belong to the same lot.

The ratio is also a useful cross-check on a supplier's claim that a material is “niacin-bound”. A chromium figure with no ligand result says nothing about the binding, and a niacin figure with no chromium result says nothing about the complex.

Why XRD is not the identity test

X-ray diffraction answers a different question. It can show that the powder is crystalline, compare the pattern with a reference and detect a crystalline second phase. It cannot name the ligand: a crystalline chromium salt, a nicotinate and a picolinate can each give a pattern, and the pattern depends on the solid form as much as on the chemistry.

Use XRD as a crystallinity or polymorph check, not as the proof of nicotinate. A “XRD conforms” line without the reference pattern and the detection limit adds little. The direct evidence is the infrared spectrum plus the HPLC result, with the chromium figure as the third leg.

What adulteration looks like

Substitution routes and the signals that catch them
RouteWhat it doesSignal and test
Chromium chloride or another chromium saltChromium passes; colour may be paleTitration, infrared, HPLC, chloride check
Dilution with a carrierChromium low; more powder per doseChromium figure, loss on drying, carrier declaration
Dye to match the grey-greenColour looks right; ligand absentInfrared, HPLC, dye screen
Unreacted nicotinic acidLigand high; chromium lowChromium-to-ligand ratio, HPLC basis
Blend with a second chromium sourceChromium on target; ligand lowRatio, infrared, HPLC
Picolinate sold as nicotinateSimilar chromium figure; different ligandInfrared, HPLC, CAS on the certificate

The last route is the one a chromium figure cannot catch, and it is why the ligand line belongs in every specification for this material. Colour is a weak signal in both directions: a pale salt can be tinted, and a declared dilution can look faintly grey-green while still being legitimate.

What to write into the specification

  • “Chromium nicotinate, chromium(III) nicotinate, CAS 64452-96-6, C18H12CrN3O6.”
  • “Chromium 12.0–12.8% by complexometric titration; assay 98.0–102.0% by HPLC, with the basis stated.”
  • “Identification by infrared and HPLC on the lot; report the spectrum and the chromatogram.”
  • “Loss on drying ≤1.0%; particle size ≥95% through 40 mesh.”
  • “No chromium source other than chromium nicotinate; no added colour.”
  • “If diluted: the carrier, the ratio and the chromium assay of the blend.”

The clause that is often missing is the one about a second chromium source. A specification that names the complex but accepts “chromium” from any source can be met by a blend, and the certificate would still be truthful about the element.

Five questions for the supplier

  1. Which ligand is this lot, and which CAS number is on the certificate?
  2. Can you provide the infrared spectrum and the HPLC chromatogram for this lot?
  3. What is the chromium result, by which method, and does it agree with the 12.43% theoretical figure?
  4. Is the lot the complex, or a blend with a carrier or a second chromium source?
  5. If the lot is disputed, will you accept a joint re-test on the retained sample?

Five direct answers, all tied to one lot code, amount to an identity file. A chromium percentage on its own does not. The product hub carries the catalog specification; the COA page shows where each figure sits on the certificate; the grades page compares the sources; the methods index covers the analytical basis; the quality page describes the release workflow.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation