01 COA & batch testing

What the COA for lecithin actually reports

Technical document 01 · Reviewed 2026-11-19 · Lecithin

On this page
  1. Reading the certificate in four blocks
  2. Acetone-insoluble matter, phosphorus and the class profile
  3. Limit, result and the gap between them
  4. Batch-to-batch variation
  5. When independent testing is worth it
  6. Comparing two lecithin certificates

A lecithin certificate has to describe a mixture, so it reports composition rather than a single potency. Acetone-insoluble matter and the phosphorus-based phospholipid figure size the phosphatide fraction; the class profile describes how that fraction is built; moisture, acid value and peroxide value record the condition of the lot. The soy source is declared separately as an allergen.

In one line

The phospholipid figure is only as good as its basis: acetone-insoluble matter, the phosphorus calculation and the class profile answer three different questions.

Reading the certificate in four blocks

Read the certificate in four blocks: what the material is, how much phosphatide it contains, what condition it is in, and what has been screened out. The identity block should name the phospholipid profile method; a bare “conforms” does not say which classes were seen. The composition block carries two numbers that are often confused, and the condition block carries the two that move first in storage.

Release lines on a soy lecithin certificate
TestMethodLimit
AppearanceVisualYellow to light brown powder or viscous fluid
IdentificationPhospholipid profile by TLC or HPLCProfile conforms to the reference
Acetone-insoluble matterGravimetric, acetone extraction≥60.0%
PhospholipidsPhosphorus method, as stated≥60.0%
MoistureLoss on drying or Karl Fischer, as stated≤1.0%
Acid valueTitration, mg KOH/g≤30
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

Two lines are missing from many lecithin certificates: peroxide value and residual solvent. Neither appears in this catalog specification, but both belong in a buyer's file when the material carries oil or comes from solvent extraction.

Acetone-insoluble matter, phosphorus and the class profile

Acetone is the reagent that separates the phosphatides from the oil. It dissolves triglycerides, free fatty acids and sterols, and the phosphatides stay behind as a residue. Weighing that residue gives acetone-insoluble matter. The number is useful, but it is a residue weight, not a class-specific assay: sugars, salts or protein that also resist acetone are counted with the phospholipids.

In the common phosphorus-based method, the phospholipid figure is a calculation, not a second weighing. Phosphorus is measured, then multiplied by a factor derived from the average molecular weight of the phosphatides. Because the classes differ in molecular weight, the factor is a convention, and the certificate should print it. A reading of 2.4% phosphorus becomes 60.0% at a factor of 25 and 63.1% at 26.3. Neither is wrong; they answer different conventions.

Moisture is a third convention. Karl Fischer titrates water; drying at 105 °C drives off water and any other volatile matter. The catalog's ≤1.0% and the E322 loss-on-drying limit of ≤2.0% are therefore not the same gate, even though both are often printed as “moisture”.

Limit, result and the gap between them

Every acceptance line needs a measured value beside it, not a restatement of the limit. A column that repeats “≥60.0%” is a blank with a number in it. Per-element metal results and a count-plus-absence microbiology statement are the minimum evidence for those lines.

What the result column should contain
ParameterLimitWhat a result should show
Acetone-insoluble matter≥60.0%A measured percentage and the drying condition
Phospholipids≥60.0%A measured percentage, the phosphorus figure and the factor
Moisture≤1.0%A measured percentage and the method
Acid value≤30 mg KOH/gA measured figure
Heavy metalsPer elementA figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Judge the lot from the numbers, not from the word “pass”. If the certificate gives a single heavy-metal total, the reader cannot see which element drove it.

Batch-to-batch variation

Four things move between lecithin lots: the oil left in the product, the phospholipid class pattern, the moisture, and the acid value. The first two start at the crush and the degumming step; the last two are influenced by drying and by storage. Colour follows all four and is the least diagnostic of them.

Watch the direction across shipments. An acid value that has climbed toward 30, a moisture that sits at 0.9%, or an acetone-insoluble figure that has fallen toward 60 is more informative than any single result. Check that the lot code on the paper is the one on the pack and on the retained sample.

When independent testing is worth it

Outside testing is worth commissioning at four moments: a new source, a new market, a claim the paperwork cannot support, or an acid value or peroxide value in dispute. The panel should be built around the question, not copied from the certificate.

For a source question, ask for acetone-insoluble matter, phosphorus, the phospholipid class profile, the fatty acid profile and the sterol profile. For a condition question, ask for acid value, peroxide value and moisture. For a market question, add the heavy-metal panel, microbiology and the residual-solvent statement.

A GMO statement for soy is usually a chain-of-custody document, not a PCR result on the lecithin: a refined phospholipid may hold little DNA. Require a detection limit with any “not detected” line.

Comparing two lecithin certificates

Compare certificates on six lines: source, acetone-insoluble figure, phospholipid basis, class profile, acid and peroxide values, and contaminants. Then compare the packs and the lot codes. Two suppliers can both say “60% lecithin” and still be selling different materials if one figure is AI and the other is a phosphorus calculation.

Ask who manufactured the lot, which soy origin it came from, and how it was degummed and dried. For the catalog specification, see the soy lecithin product page. The identity page explains the source tests; the compliance page lists the additive limits; the methods library describes the assays; the quality page sets out the release sequence.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.