01 COA & batch testing

What the COA for xylanase actually contains

Technical document 01 · Reviewed 2026-11-20 · Xylanase

On this page
  1. The certificate as a test report
  2. The unit, the substrate and the basis
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

The certificate for a xylanase lot reports appearance, identification by the activity assay, activity in U/g, loss on drying, particle size, the heavy-metal panel and microbiology. The activity row describes the enzyme, and it is comparable only when the substrate, assay pH, temperature and unit definition sit beside the number. The limits below are the catalog specification; the batch COA confirms the lot.

In one line

A xylanase certificate is only comparable when the U/g figure sits beside the substrate, the assay pH, the temperature and the unit definition that produced it.

The certificate as a test report

A certificate can be audited line by line when every row carries what was measured, the method that produced the number, and the limit the lot was released against. For activity an enzyme needs a fourth element, the assay conditions: the same powder reads differently at another pH or temperature.

Identification and activity are one measurement here: the activity assay on a xylan substrate is also the identity test, so the method behind the U/g figure is the evidence.

Release specification · xylanase powder
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan, free-flowing powder
IdentificationXylanase activity assay on a xylan substrateConforms to the reference
Xylanase activityReducing-sugar assay on xylan; unit definition stated≥100,000 U/g
Loss on dryingGravimetric≤8.0%
Particle sizeSieve analysis≥95% through 80 mesh
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent

The unit, the substrate and the basis

A xylanase unit is a rate, not a mass. The common definition is the amount of enzyme that releases one micromole of xylose equivalents per minute from xylan under the stated conditions, but the detection step may be calibrated against xylose or total reducing sugar, and those are not the same scale. The certificate has to say which one it uses and which substrate grade: birchwood xylan, oat spelt xylan and wheat arabinoxylan are not interchangeable.

The activity needs a mass basis too. A figure per gram of powder as received includes the moisture in the powder; a figure per gram of dry solids excludes it. At the 8.0% loss-on-drying limit the difference is about 8.7%, enough to make two certificates that both say 100,000 U/g disagree. State whether the U/g is as-is or corrected to dry matter, and print the loss on drying beside it.

The assay conditions belong in the same block: pH, temperature, incubation time, substrate concentration and the standard curve. A xylanase that reads 100,000 U/g at its optimum pH may read a fraction of that at the pH of a feed mash or a dough. That is a number measured elsewhere, not a failing lot. When the process condition is far from the assay window, agree an additional result there.

Release limit versus batch result

The release limit is the acceptance boundary for the lot. The batch result is what the laboratory measured on that lot, and it belongs in its own column with the method and the date. A result column filled with the specification range is not a result; it is a copy of the gate.

What the result column should contain
ParameterRelease limitResult column
Xylanase activity≥100,000 U/g by the named methodA measured U/g figure, with basis and method reference
Loss on drying≤8.0%A measured percentage
Particle size≥95% through 80 meshThe measured percentage through the sieve
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Activity is a one-sided limit, so a lot at 102,000 U/g passes and a lot at 140,000 U/g also passes. The result, not the limit, shows the headroom a process step has to consume. Ask for the activity guaranteed at the end of the declared shelf life as well as the release figure; a powder bought near that date is bought at the lower number.

What moves between batches

The fermentation sets the starting point. Strain, medium, induction and harvest shift the balance of xylanases and side activities in the broth, and recovery and standardisation decide how much of that balance reaches the powder. A supplier holding ≥100,000 U/g is choosing where in the concentrate to land, so the spread between lots is a process decision as much as a biological one.

Drying and milling move the activity as well. A wetter powder reads lower per gram, and a milling step that generates heat can destroy activity before the sieve is reached. Particle size is a finishing specification, so the 80 mesh result can move when the mill or the sieve changes. Colour is the least quantitative line and often the most revealing: a darker tan can follow a hotter dry or a longer hold while the activity still passes, so read the batch record before rejecting on colour.

The method matters as much as the number: a change of substrate grade, buffer or incubation time makes two U/g results incomparable. A trend across lots is the useful signal — activity drifting down, loss on drying climbing, a side activity appearing.

When to order an outside test

An independent test is worth ordering for a new source, a first regulated shipment, a use where the dossier depends on the activity figure, or a disputed result. The panel: activity on a retained sample by the buyer's own method, protein, loss on drying, heavy metals by ICP-MS, microbiology and a protein pattern by gel electrophoresis.

Add the side activities that matter for the use, particularly cellulase and β-glucanase, because a xylanase preparation with a large cellulase activity may be a blend sold under a single name. Ask for the detection limit on each screen; a “not detected” line without a limit describes the method, not the sample.

Traceability is part of the test. The laboratory should receive the retained sample, not a fresh scoop, and the report should carry the lot code that appears on the pouch and the drum. If a result is disputed, the referee needs the supplier's certificate and the agreed specification as well as the sample; the question is which test separates a weak lot, a heated lot and a different enzyme.

What to compare between suppliers

Put six lines side by side: unit definition and method; activity result and basis; production organism and strain; carrier; loss on drying and particle size; side-activity profile. Two quotations that agree on U/g but differ on the other five are not describing the same preparation, and the gap surfaces at the first process trial.

The second layer is traceability. The certificate should name who manufactured the lot, which organism and process were used, and which carrier was added at standardisation; the lot code should match the pouch, drum and retained sample. The catalog sits on the xylanase product page; the dilution tests are on the identity page; the method vocabulary is in the methods library; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation