02.1 Activity units

CU, EGU and FPU: what an enzyme activity unit actually means

Technical document 02.1 · Reviewed 2026-11-19 · Cellulase

On this page
  1. Four names, and one that carries no meaning
  2. The substrate decides what is counted
  3. Conditions move the number
  4. Why there is no conversion factor
  5. What the label and the specification have to say
  6. Which unit to specify

An activity unit is a rate, not a mass: it names the amount of enzyme that produces a defined change in a defined substrate under defined conditions in a defined time. CU, EGU and FPU are three assay scales with different substrates and different end points, so a figure in one unit cannot be converted into another by arithmetic. The only honest conversion is to run both assays on the same sample.

In one line

A unit exists only as the assay that defines it, so CU, EGU and FPU are three different measurements rather than three names for one number.

Four names, and one that carries no meaning

Enzyme suppliers describe the same kind of powder in different unit systems, and the purchase order has to pick one. The table sets out what each name actually measures; the entries are not ranked, because a unit is not better or worse than another, only more or less suitable for the specification that will verify it.

What each activity unit measures
UnitSubstrateWhat the assay readsWhere it comes from
CUCarboxymethyl celluloseReducing sugar released per minute, or a fluidity changeHouse method, common for cellulase preparations
EGUCarboxymethyl celluloseEndo-glucanase action, often by viscositySupplier systems built around endo activity
FPUFilter paperTotal saccharification by the whole complexIUPAC filter-paper method
IU or UStated per assayOne micromole of substrate per minuteGeneric; valid only with the assay written out
U/g, undefined——Not comparable to anything

The last row is not a joke. A figure offered as "50,000 units per gram" with no substrate, no temperature and no detection principle is not a specification; it is a number that will be argued about at goods-in.

The substrate decides what is counted

Carboxymethyl cellulose is soluble. An enzyme attacking it does not need to open up a solid surface first, so a CMC assay reports the endo-acting component of the preparation — the part that cuts the chain in the middle. That is why CU and EGU assays can both be run on CMC and still be different scales: they differ in conditions and in the detection principle, not only in the name.

Filter paper is insoluble. Breaking it down needs endo activity, exo activity and β-glucosidase working in sequence, so the filter-paper assay reports the whole complex at work on a solid substrate. The same powder that reads tens of thousands of CU/g reads a far smaller number of FPU/g, not because one assay is wrong but because they are measuring different jobs. A conversion factor between them would be a claim that the ratio of endo to exo activity is fixed across preparations, and it is not.

This is also why the identity page counts the unit and the substrate as part of the description of the material rather than as a footnote to the activity figure.

Conditions move the number

Assay conditions and their effect on the reported figure
ConditionCommon settings in tradeWhy the figure moves
pH4.5, 4.8 or 5.0The enzyme is not equally active across the window
Temperature40 °C or 50 °CRate roughly doubles per 10 °C until the protein unfolds
Incubation time30 or 60 minutesThe reaction is linear only for part of its course
DetectionDNS colour, or viscosityReducing ends and fluidity are different observations
StandardGlucose, or cellobioseThe calibration curve sets the scale of the answer

Two laboratories can follow the same unit name and land on different figures by choosing different settings within the same family. That is not misconduct; it is what an assay is. The practical answer is to write the settings into the specification and to keep them there — the COA page shows where those lines belong on the certificate.

Why there is no conversion factor

A conversion factor would need the ratio between two activities to be constant across every preparation. It is not: the fermentation, the recovery step and the standardisation each change the balance between endo activity, exo activity and β-glucosidase, so two powders with the same CU/g can sit at different FPU/g. A factor quoted in a catalogue should be read as "typical for our product", not as a physical constant.

What does convert is the total number of units. One kilogram at 50,000 CU/g carries fifty million CU. Two kilograms of a 25,000 CU/g dilution carry the same fifty million CU, spread over twice the mass. That arithmetic is exact and useful for ordering and for blend calculations; it says nothing about how the units relate to another unit system.

When a customer needs a figure in a unit the supplier does not normally report, the answer is a test, not a calculation: ask for the assay to be run on the lot, in the buyer's unit, with the method stated. The vocabulary is in the assay glossary entry.

What the label and the specification have to say

Under the EU food enzyme regulation, a food enzyme sold to a manufacturer carries its declared activity in the stated unit, alongside the name, the food-use statement, the lot and the storage conditions. A figure without the unit is an incomplete label, and a unit without the method is an incomplete specification.

In the United States the activity is a specification rather than a nutrient, so it does not belong in a nutrition panel as though it had a daily value. The ingredient declaration names the enzyme when it has a function in the finished food; the activity figure lives in the specification and the certificate. Either way, state the basis: activity at release, or activity guaranteed at the end of shelf life. The two are different promises, and a label that does not say which one it makes is ambiguous.

Which unit to specify

Specify the unit the finished-product specification can verify. For a cellulase powder dosed into a dry blend, CU/g on carboxymethyl cellulose is the practical choice, because the assay is quick, the substrate is soluble and the result tracks the endo activity the blend was built around. Choose EGU only when the supplier's system is already EGU-based and the blend is dosed against it; choose FPU when the job is saccharification of insoluble cellulose and the whole complex matters.

Whatever the choice, three things belong beside it: the method reference, the conditions, and the basis. A specification with those three can be tested at goods-in; one without them can only be discussed. The grade options themselves are compared on the grades page, and the catalog figures are on the cellulase product page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation