01 COA & batch testing

What the COA for oyster protein peptides actually contains

Technical document 01 · Reviewed 2026-11-19 · Oyster Protein Peptides

On this page
  1. The certificate as a test report
  2. Protein basis, peptide cut-off and the arithmetic between them
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. What to compare between suppliers

An oyster protein peptide certificate reports protein by Kjeldahl, peptide content by HPLC, ash, moisture, the heavy-metal panel, microbiology and particle size. Each line needs its method and its release limit, and the measured result belongs in its own column. The limits in the first table are the catalog specification; the batch COA is the document that confirms a particular pack.

In one line

The protein figure, the peptide figure and the ash figure only mean something together: each needs its method, its basis and a separate batch result on the certificate.

The certificate as a test report

A certificate is auditable when every row answers three questions: what was measured, by which method, and against which limit. A row that says only “conforms” asks the reader to accept a conclusion without the evidence. For a hydrolysate, the protein figure and the peptide figure describe different parts of the same mixture.

The identification row is comparative: “protein and peptide profile conform” means something only when the certificate names the reference and shows the chromatogram. The protein and peptide rows are separate measurements, not two names for one number.

Identity, protein, peptide and contaminants · oyster protein peptides
ParameterMethodRelease limit
AppearanceVisualOff-white to light tan powder
IdentificationProtein and peptide profileConforms to the reference
ProteinKjeldahl, factor stated≥80.0%
Peptide contentHPLC distribution≥70.0%
MoistureGravimetric≤7.0%
AshGravimetric, muffle furnace≤10.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Protein basis, peptide cut-off and the arithmetic between them

Protein by Kjeldahl is nitrogen multiplied by a factor. The factor and the basis have to be printed on the certificate, because a protein percentage without them is not comparable with another supplier's. A lot at 80.0% as-is with 6.0% moisture calculates to 85.1% on the dry basis (80.0 ÷ 0.94), so the same powder can carry two different numbers when the basis is named.

The peptide figure is a distribution, not a single substance. HPLC separates the hydrolysate into size classes, and the “≥70%” line depends on the cut-off and standard used. A percentage without the cut-off and method is not comparable. Ask for the distribution, not only the total.

On the same sample and basis, 70% peptide against 80% protein means 87.5% of the protein is in the peptide fraction (70 ÷ 80). The remainder is larger protein, free amino acids and non-protein nitrogen. The arithmetic is a consistency check: it shows whether the two figures could describe the same powder.

Ash is the third number in this group. The ≤10.0% limit is high for a protein powder because oyster tissue carries minerals and shell contact adds calcium carbonate. An ash result that climbs while protein and peptide hold steady points to the raw material or the separation step.

Release limit versus batch result

The release limit is the acceptance boundary; the batch result is what the laboratory measured. Both belong on the page, in separate columns, with the method beside them. A result column filled with the specification range is a copy of the gate, not a result.

What the result column should contain
ParameterRelease limitResult column
Protein≥80.0%, basis statedA measured percentage, with the nitrogen factor and the basis
Peptide content≥70.0%, cut-off statedA measured percentage, with the HPLC cut-off and the distribution
Moisture≤7.0%A measured percentage
Ash≤10.0%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Two lines deserve a closer look. Heavy metals must be reported per element, not as a single total, because arsenic is the element that behaves differently in a marine material. A total-arsenic result and an inorganic-arsenic result answer different questions, and the certificate should say which one it measured. Microbiology needs a count plus an absence statement; “passes” alone hides the number.

What moves between batches

The raw material comes first. Oyster species, harvest area, season and meat versus whole soft tissue all move the protein, the ash, the colour and the odour. Shell contact is the specific risk: a little shell raises the ash and calcium without changing the protein by much. The source record and the ash trend together tell the story.

The hydrolysis moves the peptide curve. Enzyme, time, temperature, pH and inactivation set the degree of hydrolysis, which changes the peptide-to-protein ratio, the bitterness, the colour after drying and the hygroscopicity. The same peptide number from a different hydrolysis route is not necessarily the same material.

Drying and milling move the physical lines. Spray drying sets the bulk density and the colour; the mill and the sieve set the 80 mesh result. A granulated lot is a different particle specification, not a cosmetic variant. Colour and odour are the least quantitative lines and often the first to reveal a change in the raw material or the drying step.

A trend across lots says more than one result near an edge. The lot code on the certificate should match the pouch, the drum and the retained sample.

When to order an outside test

Order an independent test for a new source, a first regulated-market shipment, a source claim the certificate does not prove, or a disputed result. The useful panel is not a full repeat of the certificate. It is Kjeldahl protein with the factor, HPLC peptide distribution, an amino acid profile, ash, moisture, ICP-MS for the heavy-metal panel, microbiology, and a species check on the raw material.

Add arsenic speciation when the destination market limits inorganic arsenic. Add X-ray diffraction when shell contamination is suspected, because calcite gives a sharp pattern that an amorphous peptide does not. Ask the laboratory to report its detection limit for each screen. A “not detected” line without a limit is evidence about the method's sensitivity, not about the sample.

Chain of custody matters. The sample tested should be the sample retained, and the report should identify the lot. When a result is contested, give the referee the retained sample, the certificate and the specification, and ask for tests that separate source and peptide fraction, not a repeat assay.

What to compare between suppliers

Put six lines side by side: source and species; protein method, factor and basis; peptide method and cut-off; ash; heavy metals with the arsenic basis; pack size and lot code. Two quotations that agree on protein but differ on factor or peptide cut-off are not describing the same powder.

The second layer is traceability. The certificate should say who made the lot, the raw material and hydrolysis route, and the drying and milling steps. The catalog specification sits on the oyster protein peptides product page. The tests that separate oyster from fish are on the identity page; the market conditions are on the compliance page; the test methods are indexed at resources/methods; the release workflow is on the quality page.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation