01 COA & batch testing

What the COA for oat protein actually contains

Technical document 01 · Reviewed 2026-11-20 · Oat Protein

On this page
  1. The certificate as a test report
  2. Dry basis, nitrogen and the oat factor
  3. Release limit versus batch result
  4. What moves between batches
  5. When to order an outside test
  6. Comparing two suppliers

An oat protein COA is a report on a specific lot, not a restatement of the catalog range. It carries the nitrogen method and the 5.83 factor, the dry-matter basis, the fat, fibre, ash and moisture that fill out the powder, and the identity, metal, micro and mesh lines. The limits below are the catalog gates; the measured results belong in their own column on the lot certificate.

In one line

The protein figure is a calculation: the nitrogen, the oat factor and the dry basis have to be stated together before the percentage means anything.

The certificate as a test report

The useful test of a certificate is whether a stranger could audit a row. Three elements make that possible: the parameter, the method behind the value, and the release limit. A row that stops at “conforms” withholds the evidence and asks for trust instead.

The identity line should distinguish oat protein from any other protein. A protein profile — an amino acid pattern by ion-exchange chromatography, or an electrophoretic band pattern — compared against an oat reference does that. The certificate should identify the reference and the method, not only the conclusion.

Oat protein: identity, composition and release limits
TestMethodLimit
IdentificationProtein profile against an oat referenceConforms
Protein, dry basisKjeldahl nitrogen × 5.83≥70.0%
FatSolvent extraction≤8.0%
FibreEnzymatic-gravimetric≤5.0%
AshGravimetric, ashed≤3.0%
MoistureLoss on drying≤7.0%
Heavy metalsICP-MSPb ≤3 · As ≤2 · Cd ≤1 · Hg ≤0.1 mg/kg
MicrobiologyPlate count and absence testsAPC ≤1,000 cfu/g; yeast and mould ≤100 cfu/g; E. coli and Salmonella absent
Particle sizeSieve analysis≥95% through 80 mesh

Dry basis, nitrogen and the oat factor

Oat protein is quoted on a dry basis with nitrogen multiplied by 5.83. Nitrogen is measured on the sample as received and converted to dry matter. Twelve per cent nitrogen gives 69.96%, reported as 70.0%, and the same nitrogen at 6.25 gives 75.0%. With 7.0% moisture, that dry-basis 70.0% is 65.1% in the powder as weighed.

Demand the factor, the moisture and the basis together. A percentage on its own cannot be recalculated, and a label calculated at 6.25 will disagree with a certificate calculated at 5.83 even when both describe the same drum. Kjeldahl and Dumas are both nitrogen methods; which one was used is part of the method line.

The rest of the powder is not protein. Fat, fibre, ash and water make up the balance, and two 70% concentrates from different oat streams can carry very different amounts of each. The protein number is the headline, not the whole specification.

Release limit versus batch result

On a lot certificate, each limit needs a measured value next to it. A result column that repeats the specification has measured nothing, and a single “pass” cannot be audited. The table sets out what the result column should show.

The result column on a lot certificate
ParameterLimitExpected result
Protein≥70.0% dry basis, N × 5.83The measured percentage, with the factor and the moisture
Fat≤8.0%A measured percentage
Fibre≤5.0%A measured percentage
Moisture≤7.0%A measured percentage
Heavy metalsPer elementA measured figure in mg/kg for each element
MicrobiologyCounts and absenceThe count and the absence statement for the lot

Microbiology needs a count plus an absence statement. Metals need one figure per element; a total hides cadmium, the element that matters most in an oat-derived powder. Where a result sits close to the gate, the method and its detection limit should appear beside it.

What moves between batches

Four variables explain most lot-to-lot movement: the oat source, how much starch and fibre were removed, the heat treatment and the milling. Protein, fat and fibre follow the source and the separation; moisture and mesh follow drying and milling. A different oat variety can move the fibre line without any change in the plant.

Colour should not decide a rejection by itself. The window runs from off-white to light tan, and heat treatment or a finer grind can darken the powder within it. A colour shift is a reason to ask about the process, not proof of a substitution.

Read the trend across lots rather than one certificate: protein near the 70.0% gate, fat or fibre climbing, moisture close to 7.0%. Keep the lot code consistent from certificate to pouch, drum and retain.

When to order an outside test

Outside testing is worth ordering for a new source, a regulated destination, a gluten-free or protein claim, or a disputed result. A focused panel beats a full repeat: nitrogen by Kjeldahl or Dumas, an amino acid profile, an R5 gluten ELISA, light microscopy for starch and fibre, ICP-MS for the metals, and a micro count.

Every “not detected” needs a detection limit. For gluten, a method that cannot see below 10 mg/kg leaves little margin under a 20 mg/kg claim. For cadmium, the quantification limit should sit well under the catalog gate.

Keep the chain short. Testing should use the retain, and the report should name the lot. In a dispute, give the referee the retain, the supplier’s COA and the specification, and ask for tests that separate oat protein from another protein or a dilution, not another nitrogen result.

Comparing two suppliers

Six lines carry the comparison: protein with factor and basis; fat, fibre and ash; moisture; gluten and allergen statement; metals and microbiology; pack and lot code. Two quotations that both say 70% but differ on fibre or factor describe different powders.

Then look at the process record: who made the lot, which oat stream, whether the flour was heat-treated, and which mill and sieve were used. The catalog range sits on the oat protein page. The identity page shows how oat is separated from another protein; the compliance page sets out the gluten and allergen position; the methods library covers the protein tests; the quality page follows a lot from release to dispatch. The whey protein concentrate page is the animal-protein reference.

Send the specification you intend to use — grade, quantity and destination market — and we will reply with the batch COA, the technical data sheet and a quotation.

Request a quotation